An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Meta Solution Low voltage circuit breakers

  2. CÔNG TY TNHH THƯƠNG MẠI KỸ THUẬT ASTER Số 7/31 KDC Thương Mại Sóng Thần, Kp. Nhị Đồng 1, P. Dĩ An, Tx. Dĩ An, Bình Dương Tel: (0650) 3617 012 Fax: (0650) 3617 011 Nhà cung cấp thiết bị điện chuyên nghiệp Email: contact@beeteco.com Hotline: 0909 41 61 43 DỊCH VỤ CHĂM SÓC KHÁCH HÀNG TOÀN DIỆN Tư vấn chọn sản phẩm Giao hàng tận nơi Hỗ trợ kỹ thuật Chính sách hậu mãi đa dạng

  3. Leader in Electrics & Automation Upgraded for the global best worth! Molded case circuit breaker / Earth leakage circuit breaker Marking and configuration External configuration Quick selection table (Molded Case Circuit Breakers) Quick selection table (Earth Leakage Circuit Breakers) Ratings Accessories Type numbering system Characteristics curves Dimensions Technical Information 16 18 20 28 32 72 86 87 92 109

  4. Meta solution MCCB = ELCB 4I I

  5. Metasol Molded case circuit breaker / Earth leakage circuit breaker Upgrade of Meta-MEC series Low voltage circuit breaker … �Ics = 100%×Icu �Ui = 750V �Uimp = 8kV � �Compatible and differentiated design - Compatible with the Meta-MEC - Outlook differentiated design � �Upgrade breaking capacity - N100AF : 10 � �18kA - S125AF : 25 � �37kA - S250AF : 25 � �37kA - H250AF : 35 � �50kA - N400AF : 25 � �37kA - S400AF : 35 � �50kA - S800AF : 50 � �65kA � �Same External dimension with MCCB and ELCB � �Upgrade the coordination - Upgrade the coordination with Susol / Meta-MEC mass capacity � �Ics = 100% Icu I I5

  6. MCCB/ELCB Metasol MCCB Upgrade breaking capacity 460V 85kA ABL400c 85kA ABL800c 85kA 75kA 65kA ABS800c 50�65kA ABH400c 50�65kA 50kA ABH250c 35�50kA ABH125c 35�50kA ABS400c 35�50kA ABH50c 25�50kA 37kA ABN400c 25�37kA ABN800c 35�37kA ABS125c 25�37kA ABS250c 25�37kA 26kA ABN250c 18�26kA 18kA ABS50c 10�18kA ABS60c 10�18kA ABN100c 10�18kA 14kA ABN50c 5�14kA ABN60c 5�14kA ABS30c 5�14kA 50AF 60AF 100AF 125AF 250AF 400AF 800AF 30AF 6I I

  7. Short-circuit breaking capacity Upgrade breaking capacity ● N100AF : 10 �18kA ● S125AF : 25 �37kA ● S250AF : 25 �37kA ● H250AF : 35 �50kA ● N400AF : 25 �37kA ● S400AF : 35 �50kA ● S630AF : 50 �65kA ● S800AF : 50 �65kA Metasol ELCB Upgrade breaking capacity 460V 85kA EBL400c 85kA EBL800c 85kA 75kA 65kA EBS800c 50�65kA EBH400c 50�65kA 50kA EBH250c 35�50kA EBH125c 35�50kA EBS400c 35�50kA EBH50c 25�50kA 37kA EBN400c 25�37kA EBN800c 35�37kA EBS125c 25�37kA EBS250c 25�37kA 26kA EBN250c 18�26kA 18kA EBS50c 10�18kA EBS60c 10�18kA EBN100c 10�18kA 14kA EBN50c 5�14kA EBN60c 5�14kA EBS30c 5�14kA 60AF 100AF 50AF 125AF 250AF 400AF 800AF 30AF I I7

  8. MCCB/ELCBCompatible and Standard ●100% compatible with Meta-MEC Series. ●Standardized dimension (Depth, Cutout) when the panel is made. www.dienhathe.xyz 105×165×60mm 90×155×60mm 75×130×60mm Metasol MCCB AF 30AF 50AF 60AF 100AF 125AF 250AF 400AF 800AF Type ABN50c 14kA ABN60c 14kA ABN100c 18kA ABN400c 37kA ABN800c 37kA ABN250c 26kA ABN ABS30c 14kA ABS50c 18kA ABS60c 18kA ABS400c 50kA ABS800c 65kA ABS125c 37kA ABS250c 37kA ABS ABH400c 65kA ABH50c 50kA ABH125c 50kA ABH250c 50kA ABH ABL400c 85kA ABL800c 85kA ABL Note) Dimension is for 3 pole and breaking capacity is for AC460V. 8I I

  9. ●Same external dimension with MCCB and ELCB. www.dienhathe.xyz 60mm 50mm 75×130×60mm 90×155×60mm 105×165×60mm Metasol ELCB AF 30AF 50AF 60AF 100AF 125AF 250AF 400AF 800AF Type EBN50c 14kA EBN60c 14kA EBN100c 18kA EBN400c 37kA EBN800c 37kA EBN250c 26kA EBN EBS30c 14kA EBS50c 18kA EBS60c 18kA EBS400c 50kA EBS800c 65kA EBS125c 37kA EBS250c 37kA EBS EBH50c 50kA EBH125c 50kA EBH400c 65kA EBH250c 50kA EBH EBL400c 85kA EBL800c 85kA EBL Note) Dimension is for 3 pole and breaking capacity is for AC460V. I I9

  10. MCCB/ELCBSystem overview Various installable Accessories ● Wider range of installable accessories compared to Meta MEC series. ● Composed of User Friendly Method.

  11. System overview � Breaker � Internal auxiliaries � Plug-in kit � � Rotary handle (direct) � Rotary handle (direct, key lock) � Rotary handle (extended) � Rear terminal � Terminal cover (Short, Long) � � Insulation barrier � � � � � � � � � � � I I11

  12. MCCB/ELCBInternal accessories ● ● ● ● Internal Accessories Internal Accessories can be commonly used in all Metasol MCCB and ELCB (Notice: Exception of SHT, UVT in ELCB)

  13. Internal accessories Common use to all Metasol MCCBs and ELCBs Alarm Switch (AL) Alarm switches offer provisions for immediate audio or visual indication of a tripped breaker due to overload, short-circuit, operation of shunt trip, or undervoltage trip conditions, operation of push button. They are particularly useful in automated plants where operators must be signaled about changes in the electrical distribution system. This switch features a closed contact when the circuit breaker is tripped automatically. In other words, this switch does not function when the breaker is operated manually. Its contact is open when the circuit breaker is reset. Auxiliary Switch (AX) Auxiliary switch is for applications requiring remote “ON”and “OFF”indication. Each switch contains two contacts having a common connection. One is open and the other closed when the circuit breaker is open, and vice-versa. Undervoltage trip (UVT) The undervoltage trip automatically opens a circuit breaker when voltage drops to a value ranging between 35% to 70% of the line voltage. The operation is instantaneous, and the circuit breaker cannot be reclosed until the voltage returns to 85% of line voltage. Continuously energized, the undervoltage trip must be operating be fore the circuit breaker can be closed. Shunt Trip (SHT) The shunt trip opens the mechanism in response to an externally applied voltage signal. LS shunt trips include coil clearing contacts that automatically clear the signal circuit when the mechanism has tripped.contact with live parts and thereby guarantee protection against direct contacts. AX AX AL AL AL AL AX AX AX AX AL AL AL AL AX AX SHT/UVT SHT/UVT SHT/UVT SHT/UVT AX AX AL AL AL AL AX AX SHT/UVT SHT/UVT I I13

  14. MCCB/ELCBExternal accessories External Accessories Designed for various mount and user safety.

  15. External accessories Front and rear connection Several kinds of terminals can be equipped with ELCBs as well as MCCBs. - Terminals for front connection - Rear connection terminals Plug-in base It makes to extract and/or rapidly replace the circuit breaker without having to touch connections.(Easy replacement and maintenance) Direct & Extended Rotary Handle There are two types of rotary handles. - Direct rotary handle(with or w/o key lock device) - Extended rotary handle Locking device - Fixed padlock - Removable padlock - Key lock device on direct handle Insulation barrier These allow the insulation characteristics between the phases at the connections to be increased. Insulation terminal cover The terminal covers are applied to the circuit-breaker to prevent accidental contact with live parts and thereby guarantee protection against direct contacts. I I15

  16. Marking and configuration MCCB MCCB model �ABN: Economic type �ABS: Standard type �ABH: High capacity type Standardized characteristics Ui: Rated insulation voltage Uimp: Impulse withstand voltage Ue: Rated operational voltage Icu: Ultimate breaking capacity Ics: Service breaking capacity Utilization category Rated frequency Manufacturer Standard Symbol indicating suitability for isolation as defined by IEC 947-2 MCCB Upstream connections Fixing hole Product name Brand name Operating handle Indication of closed (I/ON) position Indication of open (O/OFF) position Certification mark Company logo "push to trip" button Fixing hole Downstream connections 16

  17. ELCB ELCB model �EBN: Economic type �EBS: Standard type �EBH: High capacity type Rated frequency Standard Manufacturer Utilization category Symbol indicating suitability for isolation as defined by IEC 947-2 ELCB Upstream connections Fixing hole Brand name Indication of closed (I/ON) position Indication of open (O/OFF) position Product name Trip indication by earth fault Operating handle Residual current(I△n) setting "push to trip" button for earth fault "push to trip" button for overcurrent trip Company logo Certification mark Fixing hole Downstream connections 17

  18. External configuration MCCB ① ① Handle �Function of indications - “ON” “OFF” “TRIP” �Resetting When the handle indicates "tripped" position it must first be reset by moving the handle to the “OFF” position and then closing is possible �Trip-Free even if the handle is held at “ON”, the breaker will trip if an over current flows �Suitable for Verification of the main contact position under abnormal conditions because the handle doesn’t indicate open position Handle Terminal Arc-Extinguishing unit ② ② Arc-Extinguishing unit LS patent technique PASQ Arc-Extinguishing unit PASQ : Puffer Assisted Self-Quenching �Reduction of arc voltage for a short time Contact Mechanism Hybrid chamber Grid Ass’y Trip ③ ③ Trip button (push to trip) �Enables tripping mechanically from outside, for confirming the operation of the accessory switches and the manual resetting function. Trip button A Application of PASQ Arc Extinguishing A Application of Current limiting structure �Current limiting repulsion structure (U fixed structure) �Toggle structure - When the operating unit repulses by short circuit current, repulsion structure at bigger angle. �The reduction of breaking time by applying PASQ arc extinguishing for inhibition of arc voltage for a short time. 18

  19. ELCB ① ① Residual indication LED ① ① Residual indication LED �Normal situation is yellow , trio situation is red ② ② Residual test Button �Special design for Upgrade to prohibit resistance accident ③ ③ Residual detection unit (ZCT + Main board) �For upgrade the design is selected the 3 phase input power method and in case of Voltage problem, it can break residual current safely. ② ② Residual test Button ③ ③ Residual detection unit (ZCT + Main board) Upgrade coil operation by special design 3 phase power supply method �Sliding structure application of Trip lever �Trip special design by applying design Button method. �Upgrade the testing unit �In case of 1 phase loss residual operation upgrade �New IEC standard 19

  20. Quick selection table Molded Case Circuit Breakers MCCBs AF 30AF 50AF 60AF Type H-Type S-Type E-Type N-Type S-Type N-Type S-Type Type and Pole 2-pole ABH52c ABS32c ABE32b ABN62c ABS62c ABN52c ABS52c 3-pole ABH53c ABS33c ABE33b ABN53c ABS53c ABN63c ABS63c 4-pole ABH54c ABS34c - ABN54c ABS54c ABN64c ABS64c Rated current, In A 15, 20, 30, (3, 5, 10), 15, 20, 30 15, 20, 30, 40, 50 15, 20, 30, 40, 50, 60 40, 50 Rated operational AC(V) 690 690 460 690 690 690 690 voltage, Ue DC(V) 500 500 - 500 500 500 500 Rated insulation voltage, Ui V 750 750 460 750 750 750 750 Rated impulse withstand voltage, Uimp 8 8 6 8 8 8 8 kV Rated short-circuit breaking capacity(Icu) kA (Sym), KSC8321, IEC 60947-2 AC 690V 10 2.5 - 2.5 5 2.5 5 480/500V 35 7.5 - 7.5 10 7.5 10 415/460V 50 14 (10) 2.5 14 18 14 18 380V 50 18 (14) 2.5 18 22 18 22 220/250V 100 30 (25) 5 30 35 30 35 DC 500V(3P) 30 5 - 5 10 5 10 250V(2P) 30 5 - 5 10 5 10 Ics=%×Icu 100 100 50 100 100 100 100 Dimensions (mm) W×H×D 75×130×60mm 75×130×60mm 75×96×60mm 75×130×60mm 90×155×60mm (3-pole) (Fig. 1) (Fig. 1) (Fig. 1) (Fig. 2) More info. Ratings 38 page 32 page 34 page 36 page 36 page Curves 87 page 87 page 88 page 87 page 87 page Drawings 93 page 92 page 93 page 94 page 93 page Note) The short-circuit breaking capacities in ( ) are applied to the rated current in (3, 5, 10A) AF 50 30AF 50AF 60AF 100AF 125AF 250AF ∅4.5 Type 130 115 84 50 ABN50c 14kA ABN60c 14kA ABN100c 18kA ABN250c 26kA ABN ABS125c 37kA ABS30c 14kA ABS50c 18kA ABS60c 18kA ABS250c 37kA ABS 58 60 64 68 22 50 ABH50c 50kA ABH125c 50kA ABH250c 50kA ABH 75 82 (Fig. 1) 20

  21. 100AF 125AF 250AF N-Type S-Type H-Type S-Type H-Type N-Type ABN202c ABS202c ABH202c ABS102c ABH102c ABN102c ABN203c ABS203c ABH203c ABS103c ABH103c ABN103c ABN204c ABS204c ABH204c ABS104c ABH104c ABN104c 15, 20, 30, 40, 100, 125, 150, 175, 200, 225, 250 15, 20, 30, 40, 50, 60, 75, 100, 125 50, 60, 75, 100 690 690 690 690 690 690 500 500 500 500 500 500 750 750 750 750 750 750 8 8 8 8 8 8 8 8 10 8 10 5 18 26 35 26 35 10 26 37 50 37 50 18 30 42 50 42 50 22 65 85 100 85 100 35 10 20 30 20 30 10 10 20 30 20 30 10 100 100 100 100 100 100 105×165×60mm 90×155×60mm 75×130×60mm (Fig. 3) (Fig. 2) (Fig. 1) 44 page 42 page 40 page 89 page 88 page 87 page 95 page 94 page 93 page ∅8.2 5 50 47 100 50 155 135 59.4 102 126 144 165 CL 50 4 58 60 60 8 60 35 90 64 70 105 82 68.5 (Fig. 2) (Fig. 3) 86.85 21

  22. Quick selection table Molded Case Circuit Breakers MCCBs AF 400AF N-Type S-Type H-Type L-Type Type Type and Pole 2-pole ABN402c ABS402c ABH402c ABL402c 3-pole ABN403c ABS403c ABH403c ABL403c 4-pole ABN404c ABS404c ABH404c ABL404c Rated current, In A 250, 300, 350, 400 Rated operational AC(V) 690 690 690 690 voltage, Ue DC(V) 500 500 500 500 Rated insulation voltage, Ui V 750 750 750 750 Rated impulse withstand voltage, Uimp 8 8 8 8 kV Rated short-circuit breaking capacity(Icu) kA (Sym), KSC8321, IEC 60947-2 AC 690V 5 8 10 14 480/500V 18 35 50 65 415/460V 37 50 65 85 380V 42 65 70 100 220/250V 50 75 85 125 DC 500V(3P) 10 20 40 40 250V(2P) 10 20 40 40 Ics=%×Icu 100 100 100 75 Dimensions (mm) W×H×D 140×257×109mm (3-pole) (Fig. 4) More info. Ratings 46 page Curves 90 page Drawings 96 page AF 400AF 800AF 1000AF 1200AF Type ABN400c 37kA ABN800c 37kA ABN 257 225 215 150 ABS400c 50kA ABS1000b 65kA ABS1200b 65kA ABS800c 65kA ABS ABH400c 65kA ABH 95 109 ABL400c 85kA ABL1000b 85kA ABL1200b 85kA ABL800c 85kA ABL 113 145 (Fig. 4) 22

  23. 800 AF 1000 AF 1200 AF S-Type L-Type S-Type L-Type N-Type S-Type L-Type - - - - - ABN802c ABS802c ABL802c ABS1003b ABL1003b ABS1203b ABS1203bE ABL1203b ABN803c ABS803c ABL803c ABS1004b ABL1004b ABS1204b - ABL1204b ABN804c ABS804c ABL804c 1000 1200 500, 630, 700, 800 690 690 690 500 500 500 750 750 750 8 8 8 8 10 14 25 45 65 50 50 75 50 75 37 65 85 65 65 85 65 85 45 75 100 65 65 85 65 85 50 85 125 100 100 125 100 125 10 20 40 10 20 40 100 100 75 210×280×109mm 220×400×105mm 220×400×105mm (Fig. 5) (Fig. 6) (Fig. 6) 48 page 50 page 51 page 50 page 50 page 90 page 91 page 92 page 91 page 91 page 97 page 98 page 99 page 98 page 98 page 93 48.5 17 116 90 21.4 280 243 150 96 25 400 110 98.5 95 90 40 109 113 17 44 48.5 20 70 70 102.5 220 145 105 122.5 159 (Fig. 5) (Fig. 6) 23 230

  24. Quick selection table ZCT Molded Case Circuit Breakers MCCBs AF 30AF 50AF 60AF N-Type S-Type N-Type S-Type H-Type Type S-Type - - - - ABH52cZ Type and Pole 2-pole - ABN53cZ ABS53cZ ABN63cZ ABS63cZ ABH53cZ 3-pole ABS33cZ ABN54cZ ABS54cZ ABN64cZ ABS64cZ ABH54cZ 4-pole ABS34cZ Rated current, In A 15, 20, 30, 40, 50, 60 15, 20, 30, 40, 50 15, 20, 30 Rated operational 690 690 690 690 690 AC(V) 690 voltage, Ue 750 750 750 750 750 Rated insulation voltage, Ui V 750 Rated impulse withstand voltage, Uimp 8 8 8 8 8 8 kV Rated short-circuit breaking capacity(Icu) kA (Sym), KSC8321, IEC 60947-2 2.5 5 AC 690V 2.5 5 2.5 10 7.5 10 480/500V 7.5 10 7.5 35 14 18 415/460V 14 18 14 50 18 22 380V 18 22 18 50 30 35 220/250V 30 35 30 100 100 100 Ics=%×Icu 100 100 100 100 75×130×60mm Dimensions (mm) W×H×D 75×130×60mm 75×130×60mm 90×155×60mm (Fig. 1) (3-pole) (Fig. 1) (Fig. 1) (Fig. 2) 38 page More info. Ratings 32 page 36 page 36 page 87 page Curves 87 page 87 page 88 page 92 page Drawings 92 page 92 page 94 page Note) 1. MCCB와 동일 사양임(Size 동일). 2. ACCE : MCCB와 동일하게 취부 가능. 50 AF ∅4.5 30AF 50AF 60AF 100AF 125AF 250AF Type 130 115 84 50 ABN50c 14kA ABN60c 14kA ABN100c 18kA ABN250c 26kA ABN ABS125c 37kA ABS30c 14kA ABS50c 18kA ABS60c 18kA ABS250c 37kA ABS 58 60 64 68 22 50 ABH50c 50kA ABH125c 50kA ABH250c 50kA 75 ABH 82 (Fig. 1) 24

  25. 100AF 125AF 250AF N-Type S-Type H-Type S-Type H-Type N-Type - - - ABS102cZ ABH102cZ - ABN203cZ ABS203cZ ABH203cZ ABS103cZ ABH103cZ ABN103cZ ABN204cZ ABS204cZ ABH204cZ ABS104cZ ABH104cZ ABN104cZ 15, 20, 30, 40, 50 100, 125, 150, 175, 200, 225, 250 15, 20, 30, 40, 50, 60, 75, 100, 125 60, 75, 100, 125 690 690 690 690 690 690 750 750 750 750 750 750 8 8 8 8 8 8 8 8 10 8 10 5 18 26 35 26 35 10 26 37 50 37 50 18 30 42 50 42 50 22 65 85 100 85 100 35 100 100 100 100 100 100 105×165×60mm 90×155×60mm 75×130×60mm (Fig. 3) (Fig. 2) (Fig. 1) 44 page 42 page 40 page 89 page 88 page 87 page 95 page 94 page 92 page ∅8.2 5 50 47 100 50 155 135 59.4 102 126 144 165 CL 50 4 58 60 60 8 60 35 90 64 70 105 82 68.5 (Fig. 2) (Fig. 3) 86.85 25

  26. Quick selection table ZCT Molded Case Circuit Breakers MCCBs AF 400AF N-Type S-Type H-Type L-Type Type Type and Pole 2-pole - - 3-pole ABN403cZ ABS403cZ ABH403cZ ABL403cZ 4-pole ABN404cZ ABS404cZ ABH404cZ ABL404cZ Rated current, In A 250, 300, 350, 400 Rated operational AC(V) 690 690 690 690 voltage, Ue Rated insulation voltage, Ui V 750 750 750 750 Rated impulse withstand voltage, Uimp 8 8 8 8 kV Rated short-circuit breaking capacity(Icu) kA (Sym), KSC8321, IEC 60947-2 AC 690V 5 8 10 14 480/500V 18 35 50 65 415/460V 37 50 65 85 380V 42 65 70 100 220/250V 50 75 85 125 Ics=%×Icu 100 100 100 75 Dimensions (mm) W×H×D 140×257×109mm (3-pole) (Fig. 4) More info. Ratings 46 page Curves 90 page Drawings 96 page Note) 1. MCCB와 동일 사양임(Size 동일). 2. ACCE : MCCB와 동일하게 취부 가능. AF 400AF 800AF Type ABN400c 37kA ABN800c 37kA ABN ABS400c 50kA ABS800c 65kA ABS ABH400c 65kA ABH ABL400c 85kA ABL800c 85kA ABL 26

  27. 800 AF N-Type S-Type L-Type - - - ABN803cZ ABS803cZ ABL803cZ - - - 500, 630, 700, 800 690 690 690 750 750 750 8 8 8 8 10 14 25 45 65 37 65 85 45 75 100 50 85 125 100 100 75 210×280×109mm (Fig. 5) 48 page 90 page 97 page 280 243 150 96 257 225 215 150 95 95 109 109 113 113 145 145 (Fig. 4) (Fig. 5) 27

  28. Quick selection table Earth Leakage Circuit Breakers ELCBs AF 30AF 50AF 60AF H-Type N-Type S-Type S-Type N-Type S-Type Type - - - - EBN52c - Type and Pole 2-pole EBH53c EBN63c EBS63c EBS33c EBN53c EBS53c 3-pole EBH54c - EBS64c EBS34c - EBS54c 4-pole Overload, Short-circuit Overload, Short-circuit Overload, Short-circuit Overload, Short-circuit Protective function and Ground fault and Ground fault and Ground fault and Ground fault 60 15, 20, 30, 40, 50 15, 20, 30 15, 20, 30, 40, 50 Rated current, In A 30,100/200/500mA 30, 100/200/500mA 30, 100/200/500mA 30, 100/200/500mA Rated residual current, I△n mA 220/460 220/460 220/460 220/460 Rated operational voltage,Ue AC(V) Rated impulse withstand 6 6 6 6 kV voltage, Uimp ≤0.1 sec ≤0.1 sec ≤0.1 sec ≤0.1 sec Residual current off-time at I△n sec Rated short-circuit breaking capacity (Icu) kA (Sym), KSC8321, IEC 60947-2 14 18 14 18 50 14 AC 415/460V 30 35 30 35 100 30 220/250V 75×130×60mm 75×130×60mm 90×155×60mm 75×130×60mm Dimensions (mm) W×H×D (Fig. 1) (Fig. 1) (Fig. 2) (Fig. 1) (3-pole) 58 page 56 page 56 page 54 page More info. Ratings 87 page 87 page 88 page 87 page Curves 100 page 100 page 101 page 100 page Drawings AF 30AF 50AF 60AF 100AF 125AF 250AF Type EBN50c 14kA EBN60c 14kA EBN100c 18kA EBN250c 26kA EBN EBS125c 37kA EBS30c 14kA EBS50c 18kA EBS60c 18kA EBS250c 37kA EBS EBH50c 50kA EBH125c 50kA EBH250c 50kA EBH (Fig. 1) 28

  29. 100AF 125AF 250AF N-Type S-Type H-Type S-Type H-Type N-Type EBN202c - - - - EBN102c EBN203c EBS203c EBH203c EBS103c EBH103c EBN103c - EBS204c EBH204c EBS104c EBH104c EBN104c Overload, Short-circuit Overload, Short-circuit Overload, Short-circuit and Ground fault and Ground fault and Ground fault 100, 125, 150, 175, 200, 225, 250 15, 20, 30, 40, 50, 60, 75, 100, 125 60, 75, 100 30,100/200/500mA 30,100/200/500mA 30, 100/200/500mA 220/460 220/460 220/460 6 6 6 ≤0.1 sec ≤0.1 sec ≤0.1 sec 26 37 50 37 50 18 65 85 100 85 100 35 105×165×60mm 90×155×60mm 75×130×60mm (Fig. 3) (Fig. 2) (Fig. 1) 64 page 62 page 60 page 89 page 88 page 87 page 102 page 101 page 100 page ∅5 50 ∅4.5 47 100 135 155 50 102 144 165 CL 50 7 4.7 60 58 60 64 66.5 68.5 35 70 105 90 8 60 82 86.85 (Fig. 2) (Fig. 3) 29

  30. Quick selection table Earth Leakage Circuit Breakers ELCBs AF 400AF N-Type S-Type H-Type L-Type Type EBN403c EBS403c EBH403c EBL403c Type and Pole 3-pole EBN404c EBS404c EBH404c EBL404c 4-pole Overload, Short-circuit and Ground fault Protective function 250, 300, 350, 400 Rated current, In A 30, 100/200/500mA Rated residual current, I△n mA 220/460 220/460 220/460 220/460 Rated operational voltage,Ue AC(V) Rated impulse withstand 6 6 6 6 kV voltage, Uimp 0.1 sec 0.1 sec 0.1 sec 0.1 sec Residual current off-time at I△n sec Rated short-circuit breaking capacity (Icu) kA (Sym), KSC8321, IEC 60947-2 AC 415/460V 37 50 65 85 220/250V 50 75 85 125 Ics=%×Icu 100 100 100 75 Dimensions (mm) W×H×D 140×257×109mm (3-pole) (Fig. 4) More info. Ratings 66 page Curves 90 page Drawings 103 page AF 400AF 800AF 1000AF 1200AF Type EBN400c 37kA EBN800c 37kA EBN 257 225 215 150 EBS400c 50kA EBS800c 65kA EBS1000b 65kA EBS1200b 65kA EBS EBH400c 65kA EBH 95 109 EBL400c 85kA EBL800c 85kA EBL 113 145 (Fig. 4) 30

  31. 800 AF 1000 AF 1200 AF S-Type S-Type N-Type S-Type L-Type EBS1003b EBS1203b EBN803c EBS803c EBL803c - - - - - Overload, Short-circuit and Ground fault Overload, Short-circuit and Ground fault 1000 1200 500, 630, 700, 800 100/200/500mA 100/200/500mA 30, 100/200/500mA 220/460 220/460 220/460 220/460 220/460 6 6 6 0.1 sec 0.1 sec 0.1 sec 0.1 sec 0.1 sec 85 85 37 65 85 125 125 50 85 125 100 100 75 220×565×105mm 210×280×109mm (Fig. 6) (Fig. 5) 70 page 68 page 91 page 90 page 105 page 104 page 93 48.5 17 116 90 ∅8 21.4 ∅13.5 206 25 400 360 110 280 243 98.5 150 96 525 165 165 95 109 113 90 40 17 44 20 48.5 70 70 102.5 145 105 220 122.5 159 (Fig. 5) (Fig. 5) 231 31

  32. 30AF MCCB ABE30b Ratings 30AF Frame size E-Type Type and Pole ABE32b 2-pole ABE33b 3-pole - 4-pole 3-5-10-15-20-30A Rated current, In AC : 460V Rated operational voltage, Ue - AC : 460V Rated insulation voltage, Ui ABE32b 6kV Rated impulse withstand voltage,Uimp E-Type Rated short-circuit breaking - capacity, Icu AC 690V - IEC 60947-2 (lcu) 480/500V 2.5kA 460V 2.5kA 415V 2.5kA 380V 5kA 220/250V - DC 500V (3P) ABE33b - 250V (2P) Overload, Short-circuit Protective function Hydraulic-Magnetic Type of trip unit 12In Magnetic trip range 8500 operations Endurance Mechanical 1500 operations Electrical Front connection Connection Standard - Optional - Screw fixing Mounting Standard Dimensions (mm) Pole 2p 3p a 50 75 d c2 c1 a b 96 96 c1 Note) 60 60 b c2 Note) - - For more information d 80 80 Weight, kg Standard 0.5 0.7 �Drawings �Trip curves �Accessories �Connection and mounting ▶100 page ▶92 page ▶87 page ▶72 page 2p 3p Certification Pole CE marking ○ ○ Note) Depth by door cut size : c1 for large cut, c2 for small cut 32

  33. Ordering types Breaker types Accessories ABE type (2.5kA/460V) 2-pole 3-pole Rated current, In 3 A 5 A 10 A 15 A 20 A 30 A ABE32b/3 ABE32b/5 ABE32b/10 ABE32b/15 ABE32b/20 ABE32b/30 ABE33b/3 ABE33b/5 ABE33b/10 ABE33b/15 ABE33b/20 ABE33b/30 Electrical auxiliaries Auxiliary Switch Alarm Switch Shunt Trip AX AL SHT R T Maximum possibilities T-position R-position One of above auxiliaries Option of AX or AL Note) For more detail see 72 page External accessories Name ABE30b IB13 TBS23 Insulation barrier Short type Note) For more detail see 80 page 33

  34. 30AF MCCB ABS30c Ratings 30AF Frame size Type and Pole S-Type 2-pole ABS32c 3-pole ABS33c 4-pole ABS34c Rated current, In (3-5-10)-15-20-30A Rated operational voltage, Ue AC: 690V DC: 500V Rated insulation voltage, Ui AC: 750V ABS52c Rated impulse withstand voltage,Uimp 8kV S-Type Rated short-circuit breaking 2.5 kA capacity, Icu AC 690V 7.5 kA 480/500V 14 (10)kA 460V IEC 60947-2 (lcu) 14 (10)kA 415V 18 (14)kA 380V 30 (25)kA 220/250V 5 kA DC 500V(3P) ABS53c 5 kA 250V(2P) Protective function Overload, Short-circuit Type of trip unit Thermal-Magnetic Magnetic trip range 400A Endurance Mechanical 25000 operations Electrical 10000 operations Connection Standard Front connection Optional Rear connection Plug-in Mounting Standard Screw fixing ABS54c Dimensions (mm) 2p 3p 4p Pole d c2 c1 50 75 100 a a 130 130 130 b c1 Note) 60 60 60 b c2 Note) 64 64 64 For more information 82 82 82 d �Drawings �Trip curves �Accessories �Connection and mounting ▶110 page ▶93 page ▶87 page ▶72 page 0.5 0.7 0.9 Weight, kg Standard 2p 3p 4p Certification Pole CE marking ○ ○ ○ Note) Depth by door cut size : c1 for large cut, c2 for small cut 34

  35. Ordering types Breaker types Accessories ABS type (10kA/460V) Rated current, In 3 A 5 A 10 A 2-pole ABS32c/3 ABS32c/5 ABS32c/10 3-pole ABS33c/3 ABS33c/5 ABS33c/10 4-pole ABS34c/3 ABS34c/5 ABS34c/10 Electrical auxiliaries AX AL Auxiliary Switch Alarm Switch Combination switch Shunt Trip Undervoltage trip ABS type (14kA/460V) Rated current, In 15 A 20 A 30 A 2-pole ABS32c/15 ABS32c/20 ABS32c/30 3-pole ABS33c/15 ABS33c/20 ABS33c/30 4-pole ABS34c/15 ABS34c/20 ABS34c/30 AX+AL SHT UVT R T Maximum possibilities T-position R-position One of above auxiliaries Option of AX or AL or AX+AL Note) For more detail see 72 page External accessories Name ABS30c IB13 TCL13 TCS13 DH100 DHK100 EH100 RTR1 PB-A3 PHL100C Insulation barrier Terminal cover (Long) Terminal cover (Short) Rotary handle (Direct) Rotary handle (Direct, Key lock) Rotary handle (Extended) Rear terminal (Round) Plug-in kit Pad handle lock Note) For more detail see 80 page 35

  36. 50AF MCCB ABN50c, ABS50c, ABH50c Ratings 50AF Frame size N-Type S-Type H-Type Type and Pole ABN52c ABS52c ABH52c 2-pole ABN53c ABS53c ABH53c 3-pole ABN54c ABS54c ABH54c 4-pole 15-20-30-40-50A Rated current, In AC: 690V Rated operational voltage, Ue DC: 500V AC: 750V Rated insulation voltage, Ui ABS52c 8kV Rated impulse withstand voltage,Uimp N-Type S-Type H-Type Rated short-circuit breaking capacity, Icu 2.5kA 5kA 10kA AC 690V 7.5kA 10kA 35kA 480/500V 14kA 18kA 50kA 460V IEC 60947-2 (lcu) 14kA 18kA 50kA lcs=100%Icu 415V 18kA 22kA 50kA 380V 30kA 35kA 100kA 220/250V 5kA 10kA 30kA DC 500V(3P) ABS53c 5kA 10kA 30kA 250V(2P) Protective function Overload, Short-circuit Type of trip unit Thermal-Magnetic Magnetic trip range 12×In (30A and under: 400A) Endurance Mechanical 25000 operations Electrical 10000 operations Connection Standard Front connection Optional Rear connection Plug-in Mounting Standard Screw fixing Dimensions (mm) Pole 2p 3p 4p 2p 3p 4p 2p 3p 4p a 50 75 100 50 75 100 60 90 120 d c2 c1 a b 130 130 155 c1 Note) 60 60 60 b c2 Note) 64 64 64 For more information d 82 82 82 �Drawings �Trip curves �Accessories �Connection and mounting ▶110 page ▶93 page ▶87, 88 page ▶72 page Weight, kg Standard 0.5 0.7 0.9 0.5 0.7 0.9 0.7 1 1.2 2p 3p 4p 2p 3p 4p 2p 3p 4p Certification Pole CE marking ○ ○ ○ Note) Depth by door cut size : c1 for large cut, c2 for small cut 36

  37. Ordering types Breaker types Accessories ABN type (14kA/460V) Rated current, In 15 A 20 A 30 A 40 A 50 A 2-pole ABN52c/15 ABN52c/20 ABN52c/30 ABN52c/40 ABN52c/50 3-pole ABN53c/15 ABN53c/20 ABN53c/30 ABN53c/40 ABN53c/50 4-pole ABN54c/15 ABN54c/20 ABN54c/30 ABN54c/40 ABN54c/50 Electrical auxiliaries ABS type (18kA/460V) AX AL Auxiliary Switch Alarm Switch Combination switch Shunt Trip Undervoltage trip Rated current, In 15 A 20 A 30 A 40 A 50 A 2-pole ABS52c/15 ABS52c/20 ABS52c/30 ABS52c/40 ABS52c/50 3-pole ABS53c/15 ABS53c/20 ABS53c/30 ABS53c/40 ABS53c/50 4-pole ABS54c/15 ABS54c/20 ABS54c/30 ABS54c/40 ABS54c/50 AX+AL SHT UVT R T Maximum possibilities T-position R-position One of above auxiliaries Option of AX or AL or AX+AL ABH type (50kA/460V) Note) For more detail see 72 page Rated current, In 15 A 20 A 30 A 40 A 50 A 2-pole ABH52c/15 ABH52c/20 ABH52c/30 ABH52c/40 ABH52c/50 3-pole ABH53c/15 ABH53c/20 ABH53c/30 ABH53c/40 ABH53c/50 4-pole ABH54c/15 ABH54c/20 ABH54c/30 ABH54c/40 ABH54c/50 External accessories ABN50c ABS50c Name ABH50c IB13 TCL13 TCS13 DH100 DHK100 EH100 - RTR1 PB-A3 PHL100 IB23 TCL23 TCS23 DH125 DHK125 EH125 RTB2 RTR2 PB-C3 PHL125 Insulation barrier Terminal cover (Long) Terminal cover (Short) Rotary handle (Direct) Rotary handle (Direct, Key lock) Rotary handle (Extended) Rear terminal (Bar) Rear terminal (Round) Plug-in kit Pad handle lock Note) For more detail see 80 page 37

  38. 60AF MCCB ABN60c, ABS60c Ratings 60AF Frame size N-Type S-Type Type and Pole ABN62c ABS62c 2-pole ABN63c ABS63c 3-pole ABN64c ABS64c 4-pole 15-20-30-40-50-60A Rated current, In AC: 690V Rated operational voltage, Ue DC: 500V AC: 750V Rated insulation voltage, Ui ABS62c 8kV Rated impulse withstand voltage,Uimp N-Type S-Type Rated short-circuit breaking capacity, Icu 2.5kA 5kA AC 690V 7.5kA 10kA 480/500V 14kA 18kA 460V IEC 60947-2 (lcu) 14kA 18kA lcs=100%Icu 415V 18kA 22kA 380V 30kA 35kA 220/250V 5kA 10kA DC 500V(3P) ABS63c 5kA 10kA 250V(2P) Protective function Overload, Short-circuit Type of trip unit Thermal-Magnetic Magnetic trip range 12×In (30A and under: 400A) Endurance Mechanical 25000 operations Electrical 10000 operations Connection Standard Front connection Optional Rear connection Plug-in Mounting Standard Screw fixing ABS64c Dimensions (mm) Pole 2p 3p 4p 2p 3p 4p a 50 75 100 50 75 100 d c2 c1 a b 130 130 c1 Note) 60 60 b c2 Note) 64 64 For more information d 82 82 �Drawings �Trip curves �Accessories �Connection and mounting ▶110 page ▶93 page ▶87 page ▶72 page Weight, kg Standard 0.5 0.7 0.9 0.5 0.7 0.9 2p 3p 4p 2p 3p 4p Certification Pole CE marking ○ ○ Note) Depth by door cut size : c1 for large cut, c2 for small cut 38

  39. Ordering types Breaker types Accessories ABN type (14kA/460V) Rated current, In 15 A 20 A 30 A 40 A 50 A 60 A 2-pole ABN62c/15 ABN62c/20 ABN62c/30 ABN62c/40 ABN62c/50 ABN62c/60 3-pole ABN63c/15 ABN63c/20 ABN63c/30 ABN63c/40 ABN63c/50 ABN63c/60 4-pole ABN64c/15 ABN64c/20 ABN64c/30 ABN64c/40 ABN64c/50 ABN64c/60 Electrical auxiliaries AX AL Auxiliary Switch Alarm Switch Combination switch Shunt Trip Undervoltage trip ABS type (18kA/460V) AX+AL SHT UVT R T Rated current, In 15 A 20 A 30 A 40 A 50 A 60 A 2-pole ABS62c/15 ABS62c/20 ABS62c/30 ABS62c/40 ABS62c/50 ABS62c/60 3-pole ABS63c/15 ABS63c/20 ABS63c/30 ABS63c/40 ABS63c/50 ABS63c/60 4-pole ABS64c/15 ABS64c/20 ABS64c/30 ABS64c/40 ABS64c/50 ABS64c/60 Maximum possibilities T-position R-position One of above auxiliaries Option of AX or AL or AX+AL Note) For more detail see 72 page External accessories ABS60c ABN60c Name IB13 TCL13 TCS13 DH100 DHK100 EH100 RTB1 RTR1 PB-A3 PHL100 Insulation barrier Terminal cover (Long) Terminal cover (Short) Rotary handle (Direct) Rotary handle (Direct, Key lock) Rotary handle (Extended) Rear terminal (Bar) Rear terminal (Round) Plug-in kit Pad handle lock Note) For more detail see 80 page 39

  40. 100AF MCCB ABN100c Ratings 100AF Frame size N-Type Type and Pole ABN102c 2-pole ABN103c 3-pole ABN104c 4-pole 15-20-30-40-50-60-75-100A Rated current, In AC: 690V Rated operational voltage, Ue DC: 500V AC: 750V Rated insulation voltage, Ui ABN102c 8kV Rated impulse withstand voltage,Uimp N-Type Rated short-circuit breaking capacity, Icu 5kA AC 690V 10kA 480/500V 18kA 460V IEC 60947-2 (lcu) 18kA lcs=100%Icu 415V 22kA 380V 35kA 220/250V 10kA DC 500V(3P) ABN103c 10kA 250V(2P) Protective function Overload, Short-circuit Type of trip unit Thermal-Magnetic Magnetic trip range 400A Endurance Mechanical 25000 operations Electrical 10000 operations Connection Standard Front connection Optional Rear connection Plug-in Mounting Standard Screw fixing ABN104c Dimensions (mm) Pole 2p 3p 4p a 50 75 100 d c2 c1 a b 130 130 130 c1 Note) 60 60 60 b c2 Note) 64 64 64 For more information d 82 82 82 �Drawings �Trip curves �Accessories �Connection and mounting ▶110 page ▶93 page ▶87 page ▶72 page Weight, kg Standard 0.5 0.7 0.9 2p 3p 4p Certification Pole CE marking ○ ○ ○ Note) Depth by door cut size : c1 for large cut, c2 for small cut 40

  41. Ordering types Breaker types Accessories ABN type (14kA/460V) Rated current, In 15 A 20 A 30 A 40 A 50 A 60 A 75 A 100 A 2-pole ABN102c/15 ABN102c/20 ABN102c/30 ABN102c/40 ABN102c/50 ABN102c/60 ABN102c/75 ABN102c/100 3-pole ABN103c/15 ABN103c/20 ABN103c/30 ABN103c/40 ABN103c/50 ABN103c/60 ABN103c/75 ABN103c/100 4-pole ABN104c/15 ABN104c/20 ABN104c/30 ABN104c/40 ABN104c/50 ABN104c/60 ABN104c/75 ABN104c/100 Electrical auxiliaries AX AL Auxiliary Switch Alarm Switch Combination switch Shunt Trip Undervoltage trip AX+AL SHT UVT R T Maximum possibilities T-position R-position One of above auxiliaries Option of AX or AL or AX+AL Note) For more detail see 72 page External accessories Name ABN100c IB13 TCL13 TCS13 DH100 DHK100 EH100 RTB1 RTR1 PB-A3 PHL100 Insulation barrier Terminal cover (Long) Terminal cover (Short) Rotary handle (Direct) Rotary handle (Direct, Key lock) Rotary handle (Extended) Rear terminal (Bar) Rear terminal (Round) Plug-in kit Pad handle lock Note) For more detail see 80 page 41

  42. 125AF MCCB ABS125c, ABH125c Ratings 125AF Frame size S-Type H-Type Type and Pole ABS102c ABH102c 2-pole ABS103c ABH103c 3-pole ABS104c ABH104c 4-pole 15-20-30-40-50-60-75-100-125A Rated current, In AC: 690V Rated operational voltage, Ue DC: 500V AC: 750V Rated insulation voltage, Ui 8kV Rated impulse withstand voltage,Uimp ABS102c Rated short-circuit breaking S-Type H-Type capacity, Icu 8kA 10kA AC 690V 26kA 35kA 480/500V 37kA 50kA 460V IEC 60947-2 (lcu) 37kA 50kA lcs=100%Icu 415V 42kA 50kA 380V 85kA 100kA 220/250V 20kA 30kA DC 500V(3P) 20kA 30kA 250V(2P) Protective function Overload, Short-circuit ABS103c Thermal-Magnetic Type of trip unit 12×In (30A and under: 400A) Magnetic trip range 25000 operations Endurance Mechanical 10000 operations Electrical Front connection Connection Standard Rear connection Optional Plug-in Screw fixing Mounting Standard Dimensions (mm) Pole 2p 3p 4p 2p 3p 4p a 60 90 120 60 90 120 d c2 c1 ABS104c a b 155 155 c1 Note) 60 60 b c2 Note) 64 64 For more information d 82 82 �Drawings �Trip curves �Accessories �Connection and mounting ▶110 page ▶94 page ▶88 page ▶72 page Weight, kg Standard 0.7 1 1.2 0.7 1 1.2 2p 3p 4p 2p 3p 4p Certification Pole CE marking ○ ○ Note) Depth by door cut size : c1 for large cut, c2 for small cut 42

  43. Ordering types Breaker types Accessories ABS type (37kA/460V) Rated current, In 15 A 20 A 30 A 40 A 50 A 60 A 75 A 100 A 125 A 2-pole ABS102c/15 ABS102c/20 ABS102c/30 ABS102c/40 ABS102c/50 ABS102c/60 ABS102c/75 ABS102c/100 ABS102c/125 3-pole ABS103c/15 ABS103c/20 ABS103c/30 ABS103c/40 ABS103c/50 ABS103c/60 ABS103c/75 ABS103c/100 ABS103c/125 4-pole ABS104c/15 ABS104c/20 ABS104c/30 ABS104c/40 ABS104c/50 ABS104c/60 ABS104c/75 ABS104c/100 ABS104c/125 Electrical auxiliaries AX AL Auxiliary Switch Alarm Switch Combination switch Shunt Trip Undervoltage trip AX+AL SHT UVT R T ABH type (50kA/460V) Rated current, In 15 A 20 A 30 A 40 A 50 A 60 A 75 A 100 A 125 A 2-pole ABH102c/15 ABH102c/20 ABH102c/30 ABH102c/40 ABH102c/50 ABH102c/60 ABH102c/75 ABH102c/100 ABH102c/125 3-pole ABH103c/15 ABH103c/20 ABH103c/30 ABH103c/40 ABH103c/50 ABH103c/60 ABH103c/75 ABH103c/100 ABH103c/125 4-pole ABH104c/15 ABH104c/20 ABH104c/30 ABH104c/40 ABH104c/50 ABH104c/60 ABH104c/75 ABH104c/100 ABH104c/125 Maximum possibilities T-position R-position One of above auxiliaries Option of AX or AL or AX+AL Note) For more detail see 72 page External accessories ABS125c ABH125c Name IB23 TCL23 TCS23 DH125 DHK125 EH125 RTB2 RTR2 PB-C3 PHL125 Insulation barrier Terminal cover (Long) Terminal cover (Short) Rotary handle (Direct) Rotary handle (Direct, Key lock) Rotary handle (Extended) Rear terminal (Bar) Rear terminal (Round) Plug-in kit Pad handle lock Note) For more detail see 80 page 43

  44. 250AF MCCB ABN250c, ABS250c, ABH250c Ratings 250AF Frame size N-Type S-Type H-Type Type and Pole ABN202c ABS202c ABH202c 2-pole ABN203c ABS203c ABH203c 3-pole ABN204c ABS204c ABH204c 4-pole 100-125-150-175-200-225-250A Rated current, In AC: 690V Rated operational voltage, Ue DC: 500V AC: 750V Rated insulation voltage, Ui ABS202c 8kV Rated impulse withstand voltage,Uimp N-Type S-Type H-Type Rated short-circuit breaking 8kA 8kA 10kA capacity, Icu AC 690V 18kA 26kA 35kA 480/500V 26kA 37kA 50kA 460V IEC 60947-2 (lcu) 26kA 37kA 50kA lcs=100%Icu 415V 30kA 42kA 50kA 380V 65kA 85kA 100kA 220/250V 10kA 20kA 30kA DC 500V(3P) 10kA 20kA 30kA 250V(2P) ABS203c Protective function Overload, Short-circuit Type of trip unit Thermal-Magnetic Magnetic trip range 12×In Endurance Mechanical 25000 operations Electrical 10000 operations Connection Standard Front connection Optional Rear connection Plug-in Mounting Standard Screw fixing Dimensions (mm) Pole 2p 3p 4p 2p 3p 4p 2p 3p 4p a 105 105 140 105 105 140 105 105 140 d c2 c1 ABS204c a b 165 165 165 c1 Note) 60 60 60 b c2 Note) 64 64 64 For more information d 87 87 87 �Drawings �Trip curves �Accessories �Connection and mounting ▶110 page ▶95 page ▶89 page ▶72 page Weight, kg Standard 1.1 1.2 1.6 1.1 1.2 1.6 1.1 1.2 1.6 2p 3p 4p 2p 3p 4p 2p 3p 4p Certification Pole CE marking ○ ○ ○ Note) Depth by door cut size : c1 for large cut, c2 for small cut 44

  45. Ordering types Breaker types Accessories ABN type (25kA/460V) Rated current, In 100 A 125 A 150 A 175 A 200 A 225 A 250 A 2-pole 3-pole 4-pole ABN202c/100 ABN202c/125 ABN202c/150 ABN202c/175 ABN202c/200 ABN202c/225 ABN202c/250 ABN203c/100 ABN203c/125 ABN203c/150 ABN203c/175 ABN203c/200 ABN203c/225 ABN203c/250 ABN204c/100 ABN204c/125 ABN204c/150 ABN204c/175 ABN204c/200 ABN204c/225 ABN204c/250 Electrical auxiliaries AX AL Auxiliary Switch Alarm Switch Combination switch Shunt Trip Undervoltage trip ABS type (37kA/460V) AX+AL SHT UVT R T Rated current, In 100 A 125 A 150 A 175 A 200 A 225 A 250 A 2-pole 3-pole 4-pole ABS202c/100 ABS202c/125 ABS202c/150 ABS202c/175 ABS202c/200 ABS202c/225 ABS202c/250 ABS203c/100 ABS203c/125 ABS203c/150 ABS203c/175 ABS203c/200 ABS203c/225 ABS203c/250 ABS204c/100 ABS204c/125 ABS204c/150 ABS204c/175 ABS204c/200 ABS204c/225 ABS204c/250 Maximum possibilities T-position R-position One of above auxiliaries Option of AX or AL or AX+AL Note) For more detail see 72 page ABH type (50kA/460V) Rated current, In 100 A 125 A 150 A 175 A 200 A 225 A 250 A 2-pole 3-pole 4-pole ABH202c/100 ABH202c/125 ABH202c/150 ABH202c/175 ABH202c/200 ABH202c/225 ABH202c/250 ABH203c/100 ABH203c/125 ABH203c/150 ABH203c/175 ABH203c/200 ABH203c/225 ABH203c/250 ABH204c/100 ABH204c/125 ABH204c/150 ABH204c/175 ABH204c/200 ABH204c/225 ABH204c/250 External accessories Name ABH250c B33 TCL33 TCS33 DH250 DHK250 EH250 RTB3 RTR3 PBA250C PHL250 Insulation barrier Terminal cover (Long) Terminal cover (Short) Rotary handle (Direct) Rotary handle (Direct, Key lock) Rotary handle (Extended) Rear terminal (Bar) Rear terminal (Round) Plug-in kit Pad handle lock Note) For more detail see 80 page 45

  46. 400AF MCCB ABN400c, ABS400c, ABH400c, ABL400c Ratings 400AF Frame size Type and Pole N-Type S-Type H-Type L-Type ABN402c ABS402c ABH402c ABL402c 2-pole ABN403c ABS403c ABH403c ABL403c 3-pole ABN404c ABS404c ABH404c ABL404c 4-pole Rated current, In 250-300-350-400A Rated operational voltage, Ue AC: 690V DC: 500V Rated insulation voltage, Ui AC: 750V Rated impulse withstand voltage,Uimp 8kV ABS403c Rated short-circuit breaking N-Type S-Type H-Type L-Type capacity, Icu 5kA 8kA 10kA 14kA AC 690V 18kA 35kA 50kA 65kA 480/500V 415/460V 37kA 50kA 65kA 85kA IEC 60947-2 (lcu) 42kA 65kA 70kA 100kA 380V 220/250V 50kA 75kA 85kA 125kA 10kA 20kA 40kA 40kA DC 500V(3P) 10kA 20kA 40kA 40kA 250V(3P) 100% 100% 100% 75% lcs=100%Icu 125V ABL404c Protective function Overload, Short-circuit Type of trip unit Thermal-Magnetic Magnetic trip range 8~12In Endurance Mechanical 4000 operations Electrical 1000 operations Connection Standard Front connection Optional Rear connection Plug-in Mounting Standard Screw fixing Dimensions (mm) Pole 2p 3p 4p 2p 3p 4p 2p 3p 4p 2p 3p 4p d c2 c1 a 140 140 184 140 140 184 140 140 184 140 140 184 a b 257 257 257 257 c1 Note) 109 109 109 109 b c2 Note) 113 113 113 113 For more information d 145 145 145 145 �Drawings �Trip curves �Accessories �Connection and mounting ▶111 page ▶96 page ▶90 page ▶72 page Weight, kg Standard 5.2 6.2 7.8 5.2 6.2 7.8 5.2 6.2 7.8 5.2 6.2 7.8 Certification Pole 2p 3p 4p 2p 3p 4p 2p 3p 4p 2p 3p 4p CE marking ○ ○ ○ ○ Note) Depth by door cut size : c1 for large cut, c2 for small cut 46

  47. Ordering types Breaker types Accessories ABN type (37kA/460V) Rated current, In 250 A 300 A 350 A 400 A 2-pole 3-pole 4-pole ABN402c/250 ABN402c/300 ABN402c/350 ABN402c/400 ABN403c/250 ABN403c/300 ABN403c/350 ABN403c/400 ABN404c/250 ABN404c/300 ABN404c/350 ABN404c/400 ABS type (50kA/460V) Rated current, In 250 A 2-pole ABS402c/250 3-pole ABS403c/250 4-pole ABS404c/250 300 A 350 A 400 A ABS402c/300 ABS402c/350 ABS402c/400 ABS403c/300 ABS403c/350 ABS403c/400 ABS404c/300 ABS404c/350 ABS404c/400 Electrical auxiliaries Auxiliary Switch Alarm Switch Shunt Trip Undervoltage trip AX AL SHT UVT R T ABH type(65kA/460V) Rated current, In 250 A 2-pole 3-pole 4-pole ABH402c/250 ABH403c/250 ABH404c/250 Maximum possibilities 300 A 350 A 400 A ABH402c/300 ABH402c/350 ABH402c/400 ABH403c/300 ABH403c/350 ABH403c/400 ABH404c/300 ABH404c/350 ABH404c/400 T-position R-position Option of 2AX, 2AL and SHT or UVT Option of 2AX, 2AL and SHT or UVT Note) For more detail see 73 page ABL type(85kA/460V) Rated current, In 250 A 2-pole ABL402c/250 3-pole ABL403c/250 4-pole ABL404c/250 300 A 350 A 400 A ABL402c/300 ABL402c/350 ABL402c/400 ABL403c/300 ABL403c/350 ABL403c/400 ABL404c/300 ABL404c/350 ABL404c/400 E-70U N-70 External accessories IBL400 T1-43A T1-44A N-70 E-70U MI-43 MI-44 X-402 X-403 X-404 PB-I3-FR Insulation barrier Terminal cover (Long) - 2, 3pole Terminal cover (Long) - 4pole Rotary handle (Direct) Rotary handle (Extended) Mechanical interlock - 2, 3pole Mechanical interlock - 4pole Rear terminal - 2pole Rear terminal - 3pole Rear terminal - 4pole Plug-in kit Note) For more detail see 80 page 47

  48. 800AF MCCB ABN800c, ABS800c, ABL800c Ratings 800AF Frame size Type and Pole N-Type S-Type L-Type 2-pole ABN802c ABS802c ABL802c 3-pole ABN803c ABS803c ABL803c 4-pole ABN804c ABS804c ABL804c Rated current, In 500-630-700-800A Rated operational voltage, Ue AC: 690V DC: 500V Rated insulation voltage, Ui AC: 750V Rated impulse withstand voltage,Uimp 8kV ABS803c Rated short-circuit breaking N-Type S-Type L-Type capacity, Icu 8kA 10kA 14kA AC 690V 25kA 45kA 65kA 480/500V 37kA 65kA 85kA 415/460V IEC 60947-2 (lcu) 45kA 75kA 100kA 380V 50kA 85kA 125kA 220/250V 10kA 20kA 40kA DC 500V(3P) 10kA 20kA 40kA 250V(3P) 100% 100% 75% lcs=100%Icu 125V Protective function Overload, Short-circuit ABL804c Type of trip unit Thermal-Magnetic Magnetic trip range 8~12In Endurance Mechanical 2500 operations Electrical 500 operations Connection Standard Front connection Optional Rear connection Plug-in Mounting Standard Screw fixing Dimensions (mm) Pole 2p 3p 4p 2p 3p 4p 2p 3p 4p d c2 c1 a 210 210 280 210 210 280 210 210 280 a b 280 280 280 c1 Note) 109 109 109 b c2 Note) 113 113 113 For more information d 145 145 145 �Drawings �Trip curves �Accessories �Connection and mounting ▶111 page ▶97 page ▶90 page ▶72 page Weight, kg Standard 11 11.5 18.2 11 11.5 18.2 11 11.5 18.2 Certification Pole 2p 3p 4p 2p 3p 4p 2p 3p 4p CE marking ○ ○ ○ Note) Depth by door cut size : c1 for large cut, c2 for small cut 48

  49. Ordering types Breaker types Accessories ABN type (37kA/460V) Rated current, In 500 A 630 A 700 A 800 A 2-pole 3-pole 4-pole ABN802c/500 ABN802c/630 ABN802c/700 ABN802c/800 ABN803c/500 ABN803c/630 ABN803c/700 ABN803c/800 ABN804c/500 ABN804c/630 ABN804c/700 ABN804c/800 ABS type (65kA/460V) Rated current, In 500 A 630 A 700 A 800 A 2-pole ABS802c/500 ABS802c/630 ABS802c/700 ABS802c/800 3-pole ABS803c/500 ABS803c/630 ABS803c/700 ABS803c/800 4-pole ABS804c/500 ABS804c/630 ABS804c/700 ABS804c/800 Electrical auxiliaries Auxiliary Switch Alarm Switch Shunt Trip Undervoltage trip AX AL SHT UVT R T ABL type(85kA/460V) Rated current, In 500 A 630 A 700 A 800 A 2-pole ABL802c/500 ABL802c/630 ABL802c/700 ABL802c/800 3-pole ABL803c/500 ABL803c/630 ABL803c/700 ABL803c/800 4-pole Maximum possibilities ABL804c/500 ABL804c/630 ABL804c/700 ABL804c/800 T-position R-position Option of 2AX, 2AL and SHT or UVT Option of 2AX, 2AL and SHT or UVT Note) For more detail see 73 page E-80U N-80 External accessories IBL800 T1-63A T1-64A N-80 E-80U MI-83S MI-84S X-802 X-803 X-804 PB-J3-FR Insulation barrier Terminal cover (Long) - 2, 3pole Terminal cover (Long) - 4pole Rotary handle (Direct) Rotary handle (Extended) Mechanical interlock - 2, 3pole Mechanical interlock - 4pole Rear terminal - 2pole Rear terminal - 3pole Rear terminal - 4pole Plug-in kit Note) For more detail see 80 page 49