Westlock Control Increased Safety/Encapsulation Rotary Control Monitors ATEX/IEC

"Fully integrated and encapsulated rotary valve control monitors. Simple to install, they offer a wide range of single or dual coil Falcon solenoid valves.<br><br><br>-- Increased Safety/Encapsulation design meeting a wide range of worldwide approvals.<br>-- Cost effective alternative to Exd units in specific applications.<br>-- Quantum enclosures integrate position sensors and low power solenoid valves into a single unit.<br>-- Solenoid coils integrated within Quantum housing.<br>For More Information visit on our website:- www.instronline.com<br>Our E-mail Address:-info@instronline.com <br>

Instronline
Download Presentation

Westlock Control Increased Safety/Encapsulation Rotary Control Monitors ATEX/IEC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. QUANTUM™ ROTARY CONTROL MONITORS INCREASED SAFETY/ENCAPSULATION – ATEX/IEC Fully integrated and encapsulated rotary valve control monitors. Simple to install, they offer a wide range of single or dual coil Falcon solenoid valves FEATURES • Increased Safety/Encapsulation design meeting a wide range of worldwide approvals. • Cost effective alternative to Exd units in specific applications. • Quantum enclosures integrate position sensors and low power solenoid valves into a single unit. • Solenoid coils integrated within Quantum housing. • Choice of factory pre-wired 3/2 and 5/2 way Falcon solenoid valves. • Strong durable BeaconTM offers 360° visual indication in a choice of styles and colors. • Touch set cams are hand adjustable, spring loaded and self-locking providing quick calibration of position switches and sensors. • Terminal strips are pre-wired and numbered for ease of use. • Additional conduit for easy field wiring and mounting accessories as standard. • Wide range of switches and sensors. • Standardized mounting pattern for easy adaptation to common bracketry. • Range of drive shaft options. • Engineered resin enclosure is robust, lightweight and provides exceptional chemical, UV and impact resistance. • Aluminum enclosures with ultra-low copper content (0.2% maximum) suitable for corrosive environments. • Robust stainless steel enclosure option. • IP rated plugs certified where applicable. TECHNICAL DATA Agency approvals Area classification (ATEX/IEC) Ex II 2GD Ex mb e IIC T* Gb Ex tb IIIC T*°C Db IP6X Enclosure standards (IEC) 3700/8700 series Switches 3700/8700 series IP66/67 Magnum SPDT (hermetically sealed proximity type) switches Enclosures 3700/8700 series GENERAL APPLICATION Engineered resin Aluminum Stainless steel Quantum control monitors combine consistent and accurate valve monitoring with the control of automation process valves using integrated position sensors and low power solenoid valves in a single compact unit. Falcon solenoid valves Cv Materials Choice of 1.1, 3.5 Aluminum and stainless steel www.westlockcontrols.com VCTDS-0049-EN 17/10 A business of Crane Co. VCTDS-0049-LAYER.indd 1 10/18/2017 3:38:14 PM

  2. QUANTUM™ ROTARY CONTROL MONITORS INCREASED SAFETY/ENCAPSULATION – ATEX/IEC 3700 SERIES RESIN ENCLOSURE DIMENSIONS 4 holes with metal inserts M8 x 1.25 x 12.5 deep 35 Sq [1,378] 14 Conduit entry (Optional) 17,5 [0,689] [0,551] 6,35 [0,250] 56 [2,205] 6,35 [0,250] 28,5 [1,122] 99 [3,896] 57 Sq [2,244] 133 [5,235] 61,8 [2,434] 169 [6,665] 65 67 [2,559] [2,637] Conduit entry 4 holes with metal inserts M6 x 1.0 x 9.5 deep 130 [5,118] 75,03 [2,954] 64 Ø 129,3 107,3 Inlet port 1 Inlet port 1 94 72 72 61 50 50 8,89 [0,350] 33 75 [1,299] 19 19 [2,945] 38 38 3,98 [0,157] 9,52 Ø [0,375] 3.96 A/F Exhaust port 3 4,85 Ø [0,191] 167 [6,567] [0,156] Exhaust port 3 Exhaust port 5 61 Outlet port 2 83 Outlet port 2 40 NAMUR shaft details Falcon II 3/2 way Falcon II 5/2 way [1,575] 21 Outlet port 4 [0,827] 41 Override (Optional) contact sales office for details [1,614] Dimensions in mm, imperial dimensions (inches) in parenthesis SOLENOID VALVES TECHNICAL SPECIFICATIONS Materials of construction Enclosure Shaft and hardware Bushing Beacon visual indicator Drive shaft Westlock standard NAMUR standard Available switches The Falcon range of solenoid valves allows you to choose the material, voltage, number of ports, number of coils and Cv to best suit your application. See the Falcon II data sheet for more information. Engineered resin Stainless steel Nylon Co-polyester Double-D with ¼” A/F NAMUR standard VDI/VDE 3845 Magnum, SPDT hermetically sealed magnetic proximity switches, with tungsten contacts NOTES 1. See selection guide for standard conduit entries 2. See switches & sensors data sheet for further information 3. Please consult your sales office for any other requirements 2 VCTDS-0049-LAYER.indd 2 10/18/2017 3:38:20 PM

  3. QUANTUM™ ROTARY CONTROL MONITORS INCREASED SAFETY/ENCAPSULATION – ATEX/IEC 3700 SERIES ALUMINIUM AND STAINLESS STEEL ENCLOSURE DIMENSIONS 57 Conduit entry [2,250] 8 28,6 [1,125] [0,324] 67 62 [2,646] [2,425] 33 32 [1,299] 28,6 [1,125] [1,270] 123 [4,850] 134 [5,292] 3,98 [0,157] 57 8,89 [0,350] 157 [6,178] [2,250] Ø 9,52 [0,375] 176 [6,945] 3,96 A/F [0,156] Ø 4,85 [0,191] 4 holes tapped M6 x 1.0 x 9.5 deep (UK & US monitor) NAMUR shaft details 4 holes tapped M8 x 1.25 x 12.5 deep 5/16 - 18 UNC x 0.492 deep (US monitor) 18 [0,696] 129,3 Inlet port 1 94 ‘L’ type override 72 20 50 [0,787] 64 [2,516] 19 25 38 [0,984] 75 Exhaust port 5 [2,945] 61 Exhaust port 3 98 83 [3,860] Ooutlet port 4 152 [5,980] 165,9 [6,531] Outlet port 4 Standard profile Beacon 152 [5,980] 126,6 [4,984] Low profile Beacon Falcon II 5/2 way 91,0 [3,582] Flat cover (Thread type customer specified ¼” BSP or ¼” NPT) 24 [0,927] 6.32 A/F [0,249] Dimensions in mm, imperial dimensions (inches) in parenthesis SOLENOID VALVES TECHNICAL SPECIFICATIONS Materials of construction Enclosure The Falcon range of solenoid valves allows you to choose the material, voltage, number of ports, number of coils and Cv to best suit your application. See the Falcon II data sheet for more information. Aluminum with powder coat finish Stainless steel with electropolished finish Stainless steel Oil impregnated bronze (aluminum enclosure) PTFE (stainless steel enclosure) Co-polyester Shaft and hardware Bushing Beacon visual indicator Drive shaft Westlock standard NAMUR standard Available switches Double-D with ¼” A/F NAMUR standard VDI/VDE 3845 Magnum, SPDT hermetically sealed magnetic proximity switches, with tungsten contacts NOTES 1. See selection guide for standard conduit entries 2. See switches & sensors data sheet for further information 3. Please consult your sales office for any other requirements 3 VCTDS-0049-LAYER.indd 3 10/18/2017 3:38:20 PM

  4. QUANTUM™ ROTARY CONTROL MONITORS INCREASED SAFETY/ENCAPSULATION – ATEX/IEC 8700 SERIES RESIN ENCLOSURE DIMENSIONS 167 Standard Beacon xxx Low profile Beacon Conduit entry D Conduit entry B 74 See shaft details below 72 137 174 Valve thread type & size (¼” NPT or BSP) 11 Conduit entry A Conduit entry C Conduit entry E 42 34.7 65 41 93.8 130 Flat cover Typical 57.0 Sq 4 holes fitted with M8 x 1.25P x 7.5 deep moulded inserts 28.5 4 holes fitted with M6 x 1.0P x 7.5 deep moulded inserts 6 [0,236] 33 [1,30] 6.32 A/F [0,249] 14 [0,550] 5 [0,197] 8,9 [0,350] 9,52 Ø [0,375] 4,85 [0,191] 3.98 A/F [0,157] 9,52 [0,375] NAMUR shaft details Standard shaft details 17.5 35.0 Sq Dimensions in mm, imperial dimensions (inches) in parenthesis SOLENOID VALVES TECHNICAL SPECIFICATIONS Materials of construction Enclosure Shaft and hardware Bushing Beacon visual indicator Drive shaft Westlock standard NAMUR standard Available switches The Falcon range of solenoid valves allows you to choose the material, voltage, number of ports, number of coils and Cv to best suit your application. See the Falcon II data sheet for more information. Engineered resin Stainless steel Nylon Co-polyester Double-D with ¼” A/F NAMUR standard VDI/VDE 3845 Magnum, SPDT hermetically sealed magnetic proximity switches NOTES 1. See selection guide for standard conduit entries 2. See switches & sensors data sheet for further information 3. Please consult your sales office for any other requirements 4 VCTDS-0049-LAYER.indd 4 10/18/2017 3:38:23 PM

  5. QUANTUM™ ROTARY CONTROL MONITORS INCREASED SAFETY/ENCAPSULATION – ATEX/IEC 8700 SERIES ALUMINIUM AND STAINLESS STEEL ENCLOSURE DIMENSIONS Conduit A (Standard) Conduit B (Option) 57.15 Sq M8 x 1.25 threaded x 8 mm min deep 4 places 179 28.58 Conduit E (Option) M6 x 10 threaded x 9 mm min deep 4 places 17.53 35.15 Sq 179 183 162 14 Ø 9.525 Ø 9.513 6.35 8.89 Ø 9.525 Ø 9.513 3.9 33 6.3 A/F 3.98 A/F Ø 4.85 Standard shaft details Ø 9.52 Dimensions in mm, imperial dimensions (inches) in parenthesis SOLENOID VALVES TECHNICAL SPECIFICATIONS Materials of construction Enclosure The Falcon range of solenoid valves allows you to choose the material, voltage, number of ports, number of coils and Cv to best suit your application. See the Falcon II data sheet for more information. Aluminum with powder coat finish Stainless steel with electropolished finish Stainless steel Oil impregnated bronze (aluminum enclosure) PTFE (stainless steel enclosure) Co-polyester Shaft and hardware Bushing Beacon visual indicator Drive shaft Westlock standard NAMUR standard Available switches Double-D with ¼” A/F NAMUR standard VDI/VDE 3845 Magnum, SPDT hermetically sealed magnetic proximity switches NOTES 1. See selection guide for standard conduit entries 2. See switches & sensors data sheet for further information 3. Please consult your sales office for any other requirements 5 VCTDS-0049-LAYER.indd 5 10/18/2017 3:38:23 PM

  6. QUANTUM™ INCREASED SAFETY ROTARY CONTROL MONITORS 3700/8700 SERIES SELECTION GUIDE Housing 37 87 3700 with flanged lid (single coil) 8700 with flanged lid (single and dual coil) Cover style 4 6 Flat cover Switch type 9 0 No switches fitted With Beacon Magnum proximity switch Material A R S Aluminum Engineered resin Stainless steel Beacon type and color BY LY AR GR 00 No Beacon fitted Drive shaft type S N * Black/Yellow Black/Yellow (low profile) ANSI Red/White Green/Red B1 B3 B5 B7 B9 BM3-1 pattern 90° BM3-3 pattern 90° BM3-5 pattern 90° BM3-7 pattern 180° BM3-9 pattern 180 Westlock standard – ¼” A/F (6.32 mm) NAMUR standard shaft – VDI/VDE 3845 Non-standard (consult sales office) Solenoid body material A E Stainless steel Solenoid coil voltage C D 24 V AC Anodized aluminium 24 V DC H J 90-120 V AC 220-240 V AC Solenoid valve specification (¼” BSP entry; 1.1 Cv) 3/2 way - fail closed 3/2 way - fail open 5/2 way - fail closed 5/2 way – dual coil fail last Switch/sensor quantity 0 1 2 3 4 Four switches/sensors (consult sales office) Conduit entries supplied 1 2 3 4 Four entries (consult sales office) Unit specification AAA ADZ DAV FAN * * * (¼” NPT entry; 1.1 Cv) 3/2 way - fail closed 3/2 way - fail open 5/2 way - fail closed 5/2 way - dual coil fail last U V 1 3 K L Q S No switch/sensor fitted One switch/sensor Two switches/sensors Three switches/sensors (consult sales office) One entry (consult sales office) Two entries (consult sales office) Three entries (consult sales office) Standard build- M25 conduit entries ¾” NPT conduit entries M25 conduit entries ½” NPT conduit entries Non-standard material – (consult sales office) Certification A * Other options (consult sales office) Revision ATEX & IECEx R* Internal revision # R1 = Model number 8749ABYNACK22AAA-AR1 87 4 9 A BY N A C K 2 2 AAA A NOTES 1. Please contact your sales office for guidance on selecting the best possible combination for your control and monitoring requirements. 2. See Hazardous area classification technical bulletin for further information on global standards. 6 VCTDS-0049-LAYER.indd 6 10/18/2017 3:38:24 PM

  7. QUANTUM™ INCREASED SAFETY ROTARY CONTROL MONITORS 7 VCTDS-0049-LAYER.indd 7 10/18/2017 3:38:24 PM

  8. WESTLOCK CONTROLS 280 N. Midland Avenue,Ste 258 Saddle Brook, NJ 07663 United States Crane Co., and its subsidiaries cannot accept responsibility for possible errors in catalogues, brochures,other printed materials, and website information. Crane Co. reserves the right to alter its products without notice, including products already on order provided that such alteration can be made without changes being necessary in specifications already agreed. All trademarks in this material are the property of the Crane Co. or its subsidiaries. The Crane and Crane brands logotype (WESTLOCK CONTROLS®) are registered trademarks of Crane Co. All rights reserved. 8 VCTDS-0049-LAYER.indd 8 10/18/2017 3:38:24 PM