Toxicity Test Chamber By KDM Global Fire Testing Equipment

The NCD 1409 Toxicity Chamber is a cage of around 1 m3. Polypropylene is used to line the inside wall to both make cleaning easier and prevent the gaseous mixture from clinging. The chamber is equipped with forced air extraction, which may be opened or shut as needed using the control panel. The chamber has an airtight sampling port attached. An axial mixing fan is incorporated to ensure adequate mixing of the gaseous product inside the test chamber. The equipment's control panel can be used to modify this fan.<br>Features <br>u2022 The burner must be able to generate a flame with a height of about 100

KDM1
Download Presentation

Toxicity Test Chamber By KDM Global Fire Testing Equipment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The NCD 1409 Toxicity Chamber is a cage of around 1 m3. Polypropylene is used to line the inside wall to both make cleaning easier and prevent the gaseous mixture from clinging. The chamber is equipped with forced air extraction, which may be opened or shut as needed using the control panel. The chamber has an airtight sampling port attached. An axial mixing fan is incorporated to ensure adequate mixing of the gaseous product inside the test chamber. The equipment's control panel can be used to modify this fan. Features • The burner must be able to generate a flame with a height of about 100 mm. The burner can be started and stopped remotely from outside the chamber. The NCD 1409 Toxicity Chamber is a cage of around 1 m3. Polypropylene is used to line the inside wall to both make cleaning easier and prevent the gaseous mixture from clinging. The chamber is equipped with forced air extraction, which may be opened or shut as needed using the control panel. The chamber has an airtight sampling port attached. An axial mixing fan is incorporated to ensure adequate mixing of the gaseous product inside the test chamber. The equipment's control panel can be used to modify this fan. Product Information The volume of the chamber is 1 m3. Flow Meter: 20 LPM for air and 15 LPM for natural gas K-type digital thermocouple used as a temperature gauge. 4 digit digital timer

More Related