1 / 2

Fiber Optic Chlorophyll Analyzer

The Fiber-Optic Chlorophyll Analyzer adopts the principle of the fluorescence method. According to the spectral absorption characteristics of chlorophyll, the water body is irradiated by a high-energy LED light source, and the chlorophyll a in the water body is excited to generate fluorescence of a specific wavelength, and the concentration of chlorophyll a in the water is measured. The sensor's fiber-optic structure provides excellent repeatability and stability and is less susceptible to ambient light.

Vasthi2
Download Presentation

Fiber Optic Chlorophyll Analyzer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fiber Optic Chlorophyll Analyzer Fiber Optic Chlorophyll Analyzer MODEL NO VEFOC1008 The Fiber-optic Chlorophyll Analyzer adopts the principle of fluorescence method. According to the spectral absorption characteristics of chlorophyll a, the water body is irradiated by a high-energy LED light source, and the chlorophyll a in the water body is excited to generate fluorescence of a specific wavelength, and the concentration of chlorophyll a in the water is measured. The sensor's fiber-optic structure provides excellent repeatability and stability and is less susceptible to ambient light. With an automatic cleaning brush to eliminate air bubbles, reduce the impact of contamination on the measurement, make the maintenance cycle longer, and maintain excellent stability for long-term online use.

  2. Feature  Digital sensor, RS-485 output, support MODBUS.  Automatic cleaning brush to prevent contamination and eliminate air bubbles  Direct measurement is easier than traditional analysis methods  Continuous online monitoring and real-time control of water quality Technical Specifcations Product name Fiber Optic Chlorophyll Analyzer VEFOC1008A Self-cleaning Chlorophyll Analyzer VEFOC1008B Model Principle Fluorescence method Range 0~400 ug/L or 0 ~100 RFU Resolution 0.1μg/L or 0.1% RFU Linearity R2>0.99 temperature range 0~ 50°C Protection level Ip68 Depth 60m Max 10m Max Sensor interface Support RS-485, MODBUS protocol assembly Power information Input type DC 5~12V, I<50mA DC 5~12V, I<50mA (Without wiping) Probe cable length 10 meters (default), can be customized Dimension Φ22*120 mm SS316 (customizable titanium alloy) Φ33*156mm Housing material Optical window Self-cleaning system optical fiber no Yes VASTHI INSTRUMENTS Plot no:21&22, Block no:24, Phase-IV Auto Nagar, Guntur-522001. Andhra Pradesh, India. Tel:+91 863 22 53 667, +91 738 2708 685, +91 958 1678 685 web: www. vasthi. com, E:info@vasthi.com.

More Related