1 / 18

Comparison of MC and data

Comparison of MC and data. Abelardo Moralejo Padova. Outline. We have compared the data from a few Off Crab data runs from January 27 th with MC protons. 18 data runs: 12544 - 12550 and 12640 - 12650

amanda
Download Presentation

Comparison of MC and data

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Comparison of MC and data Abelardo Moralejo Padova

  2. Outline • We have compared the data from a few Off Crab data runs from January 27th with MC protons. • 18 data runs: 12544 - 12550 and 12640 - 12650 • Total time (not live-time) 231 seconds, zenith angle about 10 deg. Average raw rate ~ 130 Hz • Used MC from 0 to 30 degrees (for better statistics) • Approximate normalizations of MC and data to obtain rates which can be compared; drawbacks: only protons considered in MC, proton flux uncertainty, no dead time correction in data…

  3. Reconstruction of data • Calibration: used F-factor method (as it was in cvs around mid March). Pedestal run 12543, calibration runs 12526 - 12529 • Signal extraction with MExtractSignal3: Integration window 6 slices, the same for all pixels, determined event by event from the position of highest non-saturated HG peak. • 41 pixels with no valid calibration interpolated using MBlindPixelsCalc2.

  4. Treatment of MC • Used preliminary version of camera simulation v 0.7 • Several new features implemented: realistic pulse shape from pulpo setup, gaussian blurring of spot PSF (RMS in x and y ~ 3cm), new calculation of pedestal RMS. • Tried to set both the gain (ADC counts/photoelectron) and pedestal fluctuations of pixels close to those observed in the data. RMS of pedestal was tuned to be the same in ADC counts (~7.3 and 4.9 for inner and outer pixels resp.) • Gains were set to 5 and 1.25 ADC cts / phe, but in the data they have turned out to be more like 8, 1.7 

  5. Treatment of MC (II) • The most relevant consequence is that noise in MC, in photons, is larger than in data. For 6-slice integration, approximate RMS in photons is: MC : 18 (inner) 48 (outer) Data: 11 32 Patch: we will correct for this by applying higher tail-cuts in data with respect to MC: MC : 4 , 2  Data : 6 , 3  Another (less important) consequence is that saturation will occur at a different light level. BOTTOM LINE: all this has to be redone in any case

  6. MC calibration(mccalibrate.C) • Used MC gammas with no added noise as calibration events • First loop: relative “calibration” (values simply read from MC headers): inner/outer pixels and hi/lo gain. • Calculate Size and correlate with (known # of photons) • Second loop: apply obtained conversion factor MCerPhotEvt

  7. Treatment of MC (III) • For all the rest, MC events were reconstructed in the same way as real data (used MExtractSignal3), and the same 41 pixels were treated as faulty and therefore interpolated. • Note that the results presented heresupersede those in the Padua web page, where for instance different signal extraction methods had been used for data and MC. This is the case even if the agreement between data and MC seems to be worse now in some aspects.

  8. Odd events excluded from data

  9. Core pixels: those surviving first cleaning level Spectrum of # of “core pixels”

  10. Size spectrum (same plot in log Y) Beware: absolute Size scale not more accurate than ~20% (differences in mirror, QE… etc). Y-axis normalization: uncertainty of the same order

  11. “Corrected” Size spectrum Applied a factor 0.77 to MC light values, to account for incomplete mirror dish in data (~10%?) and higher QE in MC (0.21 vs estimated 0.18)

  12. Adding cuts in # core pixels

  13. ??? BIG mismatch: DIST

  14. > 60 core pixels LENGTH

  15. WIDTH

  16. 250 - 300 GeV ? Energy threshold, MC gammas

  17. Size (corrected *0.77) > 3000 photons > 6 core pixels Effective area, MC gammas Rate estimate for Crab: ~ 6.6 events /min (before cuts). Seems low compared to excesses observed in data (see i.e. Munich analysis) ? Likely explanation: harder cleaning in our analysis. This implies threshold is also overestimated (don’t take these two slides too seriously)

  18. Conclusion To be done in the boot camp • Up to now the MC does not seem to reproduce well the data. • A certain agreement in LENGTH and WIDTH distributions for large events might be just a coincidence, given the large mismatch of DIST. Also large discrepancy in Size for small events. • One problem has been identified: different noise level (in terms of photons), but seems unlikely it can account for the discrepancies. • Get these 18 data runs checked and analyzed by experts to exclude the possibility of having made some mistake in the calibration… etc. Use latest Mars from cvs. • Investigate the reason for the differences, using recently produced camera files with a (hopefully) more realistic noise and QE. New image parameters may be helpful.

More Related