An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Operating & MaintainingDental EquipmentPositioning a Patient in a Dental ChairUnit 18.6 -18.8 Medical Technologies Jr. Program Dr. Hale

  2. Introduction 1. Care of dental equipment may be a dental assistant’s responsibility 2. Check manufacturer’s recommendations prior to using or caring for equipment 3. Following information provides basic facts on equipment

  3. Infection Control 1. Essential while operating and maintaining any dental equipment 2. Equipment can be contaminated with blood, saliva, and body fluids 3. Standard precautions must be observed at all times 4. Personal protective equipment (PPE) must be worn at all times while performing dental procedures and operating dental equipment

  4. a. PPE includes gloves, gown, mask, and protective eyewear b. Gloves and mask discarded after each patient c. Masks must be changed anytime they become wet or are worn for longer than 30 minutes d. Protective eyewear must be disinfected, rinsed, and dried before being used for another patient

  5. Dental PPE

  6. 5. After any dental procedure, contaminated equipment must be disinfected or sterilized before it is used for another patient 6. Gloves must be worn while cleaning contaminated areas 7. Protective barriers must be placed on many parts of the equipment prior to use

  7. a. Special covers can be purchased for dental chair, handles and switches on dental light, and to cover X-ray head b. Plastic wrap or aluminum foil can also be used to cover surfaces such as handles and switches on dental light c. Clear plastic wrap can be used on X-ray tube head

  8. d. Plastic backed paper or plastic wrap can be used on the headrest, armrest, and other parts of dental chair, and to cover tops of dental carts

  9. 8. When procedure is complete, contaminated barriers must be removed a. Assistant must wear gloves to remove barriers b. Areas must then be disinfected or sterilized if possible

  10. 1) All surfaces are sprayed with a disinfectant 2) Wiped to remove any particles or debris 3) Areas are then sprayed a second time 4) Solution is left in place for the period of time recommended by the manufacturer, usually 10 minutes 5) All surfaces are then wiped again

  11. c. Gloves must then be removed and hands washed thoroughly d. Clean protective barriers are put in place before next dental procedure

  12. 9. Transmission of disease by dental equipment can be prevented by observing standard precautions and proper disinfection and/or sterilization procedures

  13. Dental Light 1. Most lights are mounted on ceiling or to the dental unit 2. Used to illuminate the oral cavity or mouth 3. Light is positioned 30 to 50 inches from oral cavity a. Put in place after patient positioned in dental chair b. Should be positioned so light illuminates oral cavity but does not shine in patient’s eyes

  14. Dental Lights Position light 30 – 50 inches from patient

  15. 4. Lights contain dimmer switches to adjust the intensity of the light 5. Prior to a procedure, protective barriers are placed on handles and switches of the light a. Plastic wrap, aluminum foil, or commercial covers are used b. Barriers must be removed and replaced with clean covers after each patient

  16. 6. Frequent cleaning of the light is important a. All parts that are touched must be disinfected after each patient b. Mild detergent and soft cloth should be used to clean light shield 7. All moving parts on light should be lubricated with general all-purpose oil at least once a week

  17. Dental Chair 1. Designed to position patient comfortably while providing doctor and assistant easy access to oral cavity 2. Most chairs have thin, narrow headrests a. Allows doctor and assistant to position them- selves close to patient b. Patient’s head must be resting on upper narrow headrest c. Position short adults and children in chair starting with correct placement of the head

  18. 3. Patient placed in supine or lying down position in four handed dentistry 4. Chair controls a. Most chairs contain controls on both sides and/or on the floor so they can be operated by doctor or assistant b. Control to raise or lower height of chair usually located on chair base and operated by foot

  19. Four-handed area

  20. c. Control to recline or raise chair usually located on side of chair by headrest and operated by hand d. Chair lock control on base usually operated by foot 1) Prevents movement of the chair 2) Must be locked when patient getting in or out of chair

  21. 5. Cleaning chair a. Chair must be cleaned between patients b. Headrest, armrest, and any other contaminated area should be wiped clean with a disinfectant, then re-sprayed, left in place for the required time, and wiped again

  22. c. Headrest usually covered with plastic disposable cover that is discarded after each use and replaced with clean cover d. Most manufacturers recommend frequent thorough cleaning with special upholstery cleaners or mild soap solutions

  23. 6. Principles for seating patient in dental chair a. Chair must be locked in upright position before patient gets in or out of chair 1) Patient could be injured if chair moves 2) Always check chair lock before seating patient or assisting patient out of chair b. Elevate chair to height that will allow doctor to be seated comfortably by chair with patient’s head above doctor’s lap

  24. c. Recline the chair slowly 1) Lowering to supine position quickly can cause dizziness, discomfort, and fear in some patients 2) Best to lower chair part way, pause, and then complete lowering the chair

  25. d. Recline chair until patient lying basically flat 1) Imaginary line from patient’s chin to ankles should be parallel with the floor 2) Patient’s legs and head should be at same level e. Explain all movements of the chair to patients – unexpected movements could frighten patient

  26. Dental Chairs

  27. Dental Chairs…

  28. f. Before dental procedures performed, place protective drape over patient’s chest 1) Protects clothing during procedure 2) Plastic side placed against clothing and paper side faces up aa. Paper absorbs any moisture bb. Plastic prevents moisture from soaking through to patient’s clothing

  29. Dental Drapes

  30. g. Maintain friendly, pleasant attitude toward patient 1) Make patient feel welcome 2) Allow patient to talk about their interests 3) Knowledge about patient allows you to ask questions aa. “How was your vacation?” bb. “How did your team do in the last game?” cc. “I hope you enjoy your first year at college.”

  31. Air Compressor 1. Provides air pressure to operate handpieces and air syringes 2. Usually located in storage area or basement, and air lines carry air pressure to dental unit 3. Units usually set to provide 100 pounds of pressure 4. Maintenance of unit

  32. a. Read and follow manufacturer’s instructions b. Some are sealed units and require no lubrication c. Other units require oil to operate 1) Check oil level frequently, usually weekly 2) If unit contains oil reservoir, remove cap or plug and check oil level 3) Report low oil levels immediately

  33. d. Drain water that accumulates in main tank from compression of moist air 1) Water should be drained daily 2) Make sure pressure of tank is at zero 3) Open drain faucet or valve to release accumulated water

  34. Oral Evacuation Systemor Central Vacuum System 1. Uses water for forming a suction or vacuum system to dental unit a. Aids in removing particles, debris, and liquids from oral cavity b. Similar to action of vacuum cleaner 2. System consists of main pump with vacuum lines to dental unit and is usually located in a storage area or utility closet

  35. 3. Electrical control switches usually located on or near dental unit to turn pump on and off 4. Wastes and liquids drawn into system are discharged into a sanitary sewer line 5. Solids collector trap is located on oral evacuation unit or in the dental unit

  36. a. Trap catches large particles and must be cleaned daily b. Particles should be emptied into paper towel and placed in correct waste container c. Trap should be washed with mild detergent, rinsed thoroughly, and dried d. Some manufacturers recommend using germicide spray or liquid daily to prevent growth of organisms and development of unpleasant odors

  37. 6. Read and follow manufacturer’s instructions on specific care and maintenance or oral evacuation system

  38. Assistant’s Cart 1. Vary from office to office 2. Most carts contain same basic equipment 3. Drawers or areas for instrument storage found on most carts 4. Many carts have sliding top with storage area under top 5. Hand-pieces such as tri-flow syringe, saliva ejector, and high velocity oral evacuator frequently located on cart

  39. Tri-Flow or Air-Water Syringe 1. Provides air, water, or combination of air and water for various dental procedures 2. After each use, air-water syringe should be run for at least 30 seconds to flush out the unit 3. Plastic disposable tips are discarded 4. Metal tip is removed for sterilization in an autoclave

  40. 5. Tip must be changed and replaced with sterile tip after each patient 6. Syringe and tubing must be wiped with disinfectant after each patient

  41. Saliva Ejector 1. Provides a constant low volume suction to remove saliva from mouth 2. Most units contain screw-type know to turn suction on and off 3. Tips are disposable and must be changed between patients Saliva Ejectors

  42. 4. Tip holder is covered with a protective barrier during use a. Barrier is removed after each patient b. Holder and tubing are disinfected c. New barrier is put in place 5. At least once daily, inside of tip holder should be cleaned thoroughly with a brush

  43. 6. Germicide solution or spray can also be used for the inside of the tip holder 7. The tubing can be sanitized by turning the saliva ejector on and drawing a disinfecting and deodorizing solution into it

  44. High Velocity Oral Evacuator 1. Also called high volume or high vacuum evacuator 2. Used to remove particles, debris, and large amounts of liquid from the oral cavity 3. Various tips are used in evacuator a. Plastic disposable tips are discarded after each patient b. Metal tips and non-disposable heavy plastic tips are cleaned and sterilized in an autoclave after each patient

  45. Oral Evacuator Tips

  46. 4. Evacuator holder is covered with a protective barrier during the procedure a. Barrier is removed after each patient b. Holder and tubing are disinfected c. New barrier is put in place 5. Disinfecting and deodorizing solution can be suctioned into the tubing to sanitize the interior of the unit

More Related