An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Wellcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎 UFM610

  2. The Transit Time Clamp-on Flow Metering Technique

  3. Introduction • Principle of operation. • Modes of operation. • Installation guidelines.

  4. Principle of operation Sensor Block Sensor Block B A Liquid Flow • The general principle of time of flight flow measurement. • The phase measurement system. • Modes of operation

  5. The general principle of time of flight flow measurement. Approximate relationship between fluid velocity and measured time. Does not include clamp on transducer delays. Vf = Flow velocity l = Distance between transducers Cf = Path length between transducer faces t = Transit-time downstream Kn = Profile correction factor  = Propagation angle

  6. Typical sound path for a clamp on ultrasonic meter Pipe cut through side view Transducers Steel Plastic Line represents path of sound wave Water

  7. The direct time measurement system  

  8. Modes of operation Sensor Block A Pipe wall Liquid Flow B Sensor Block Sensor Block Sensor Block B A Liquid Flow Pipe wall • Reflex mounting • ease of setup • good results over a • broad range of • applications • Diagonal mounting • extends the readable • pipe diameter for given • sensors • better for high flows • betterwith turbulent • applications

  9. Modes of operation Sensor Block Sensor Block B A Sensor Block Sensor Block B A Liquid Flow Pipe wall Liquid Flow Pipe wall • Double reflex mounting • ease of setup • useful forsmaller pipe • diameters • good on low flow rates • Triple reflex mounting • ease of setup • useful forsmaller pipe • diameters • good on low flow rates

  10. Installation guidelines • Transducer positioning. • Flow profiles

  11. Ultrasonic flow meter axial and radial sensor location

  12. Summary • Principle of operation. • Modes of operation. • Installation guidelines.