問題描述

客訴報告. 根本原因. 問題描述. 一電 H07 投訴機种 1AD41-000-1 D10 反向 200 臺 , 經確認為 S16 線夜班 8/2 生產. D10 位置 PCB 板變更方向 , 貼片時 , 未確認 , 造成反向. 不良原因分析 :. 錯誤規格 :. 料號 : R90269-9799I-FA 規格 : RLS4148TE-11 反向. 1. 品管員 沈操 (21304142) 確認尾件時 , 未按流程 作業 , 導致 D10 位置反向 , 未能及時發現 , 流入下 一制程段 . 2.AOI 程式員韓子華未對變更內容進行修改程

Download Presentation

問題描述

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 客訴報告 根本原因 問題描述 一電H07投訴機种1AD41-000-1 D10反向200臺 , 經確認為S16線夜班8/2生產. D10位置 PCB板變更方向, 貼片時, 未確認, 造成反向 不良原因分析: 錯誤規格: 料號: R90269-9799I-FA 規格:RLS4148TE-11 反向 1.品管員沈操(21304142)確認尾件時,未按流程 作業,導致D10位置反向,未能及時發現,流入下 一制程段. 2.AOI程式員韓子華未對變更內容進行修改程 式,造成AOI檢測未報異常. 3.生產領班黎會子只核對材料,未確認貼片后第 一片板極性 4.技朮員黃興樂(21208952)未按照換線首 件確認流程執行,確認所有極性元件方向,未發 現程序D10反向 5.機种RD廖練斌傳送資料 PDIF標示与PCB板 絲印標示相反 發生時間: 2013/08/09 機种名稱: 1AD41-000-1 不良現象: 反向 不 良 比: 200/200 PCS Q C: 王先平 鄭均會 龐佑淑 工 程: 鄒 云 范春亮 樊瑞華 生 產: 李小蘭 潘其林 李 鵬 黎會子 責任部門: SMT品管/生產/工程

  2. 客訴報告 改善對策 有效性驗證&預防再發生 圍堵計劃: 跟蹤H07線重工無異常 1.SMT已出貨,無庫存. 2.H07线立即安排重工處理. 改善對策 1.E/C變更內容由領班(代理人)負責每天跟 蹤,並與在線品管進行確認. 2.AOI程式員制作新程式時,需核對二、三极 体及IC等有极性元件方向与PCB板絲印方 向一致 3.換線時, 領班需核對首件極性. 4.技術員換線時核對极性元件方向與PCB板 絲印方向一致. 若反向,現場修改程序;由程 序員回存新程序. 5.E/C變更(PCB Layout),附帶E/C變更內容, 離線程式製作人員,核對無誤后上線. 狀態: Close

More Related