Firefighter III

Firefighter III. Module A Fire Hose And Appliances (4-12). 3-6.1. Identify the adapters and appliances to be used in three specific fire ground situations: (4-12.2). I. Selecting adapters: a)  To reduce the size of a hose: i ) Determine the size of the current hose line.

ellwood
Download Presentation

Firefighter III

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Firefighter III Module A Fire Hose And Appliances (4-12)

  2. 3-6.1. Identify the adapters and appliances to be used in three specific fire ground situations: (4-12.2) • I. Selecting adapters: • a) To reduce the size of a hose: • i) Determine the size of the current hose line. • ii) Determine the size of hose line needed. • iii) Connect appropriate reducer to current hose line. • iv) Connect desired hose line to reducer.

  3. 3-6.1. Identify the adapters and appliances to be used in three specific fire ground situations: (4-12.2) • b) Divide one line into two lines of the same size: • i) Determine the size of current hose line. • ii) Determine the size of hose line needed. • iii) Connect proper size wye to the current hose line. • iv) Connect desired hose lines to wye. v) Station a firefighter at the wye to control the valves

  4. -6.1. Identify the adapters and appliances to be used in three specific fire ground situations: (4-12.2) • c) Divide one line into several lines of different sizes: • i) Determine size of current hose line. • ii) Determine size of hose lines needed. • iii) Connect proper size water thief to current hose line. • iv) Connect desired hose lines to water thief. • v) Station firefighter at wye to control valves.

  5. -6.1. Identify the adapters and appliances to be used in three specific fire ground situations: (4-12.2) • d) Supply a single hose line with two or more hose lines: • i) Determine size of supply hose lines. • ii) Determine size of hose line to be supplied. • iii) Connect supply hose line to Siamese. • iv) Connect supplied hose line to Siamese.

  6. -6.1. Identify the adapters and appliances to be used in three specific fire ground situations: (4-12.2) • e) Connect two couplings of same sex together: • i) Determine sex of couplings. • ii) Select a double male if the sex is female, or a double female if the sex is male. • iii) Connect the couplings to the appropriate fitting.