1 / 4

DialysisMachine/ Weight-88kg

Dialysis Machine is indicated for acute and chronic hemodialysis therapy. Consists of an access device, blood tubing, blood pump and dialyzer. To prevent the chemical deposits machines are rinsed with acetic acid or citric acid. Reliability and safety provided through dual control system along with multiple pressure, air conductivity and blood leakage detectors. It is a premium quality dialysis machine. Our machines are compact sized and extensively acclaimed for durability and uninterrupted performance.

evieabimed
Download Presentation

DialysisMachine/ Weight-88kg

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Dialysis Machine AM-DM41 www.abimed.com | info@abimed.com

  2. Dialysis Machine AM-DM41 Dialysis Machine AM-DM41 is indicated for acute and chronic hemodialysis therapy. Consists of an access device, blood tubing, blood pump and dialyzer. To prevent the chemical deposits machines are rinsed with ace�c acid or citric acid. Reliability and safety provided through dual control system along with mul�ple pressure, air conduc�vity and blood leakage detectors. It is a premium quality dialysis machine. Our machines are compact sized and extensively acclaimed for durability and uninterrupted performance. Features  Self-checking func�on  Temperature and electric conduc�vity monitoring  Automa�c disinfec�on cleaning program  Arterial pressure, trans-membrane pressure and venous pressure monitoring  Blood leakage detector  Double system of conduc�vity to provide safety of pa�ents  8 kinds of UF profiling to meet different clinical applica�ons requirement  Easy maintenance due to separate electric and a hydraulic part Technical Parameter Model AM-DM41 Power Supply AC220V±10%, 47 to 63HZ Water Supply Water inlet Pressure 1.5 to 6.0 bar Water Inlet Temperature 50C to 320C Maximum Drain Height 1m Supply Pressure 0 to 2 m suc�on height Current Consump�on Maximum 10 A Extracorporeal Circuit Arterial Pressure Monitoring Display Range -380 mm Hg to+400 mm Hg Accuracy ±10 mm Hg Resolu�on 1 mm Hg Venous Pressure Monitoring Display range -180 mmHg to+600 mmHg Accuracy ±10 mmHg Resolu�on 1 mmHg

  3. Dialysis Machine AM-DM41 Trans-Membrane Pressure Monitoring Display Range -180 mmHg to+600 mmHg Accuracy ±20 mm Hg Resolu�on 1 mm Hg Arterial Blood Pump Blood Flow Range 30 to 600ml/min in 8 mm bloodline systems Accuracy ±10% Air Bubble Pump By ultrasound transmission, addi�onal op�cal monitoring in venous clamp Heparin Pump Delivery Range 0ml/h to 10ml/h Bolus Func�on Maximum 20 mL per bolus Syringe Size 10, 20, 30, 50 ml Dialysis Fluid Circuit Dialysis Fluid Flow Range 100 to 800 mL/min Dialysis Fluid Temperature Dialysis Fluid 34.00C to 40.00C 12 to 16 mS/cm (250C) Range Conduc�vity Accuracy ±0.1 mS/cm Acid concentra�on Default mixing ra�o dialysis fluid Range 1+34 (others possible) 125 to 150 mmol/L Bicarbonate concentra�on dialysis fluid Default mixing ra�o Range 1+27.6 (others possible) -8 to +8 mmol/L bicarbonate Ultrafiltra�on UF rate Accuracy 0ml/h to 4000ml/h ±1% Parameter Displayed UF goal, UF �me, UF rate, UF volume Blood Leak Detector Sensi�vity ≤0.35 mL blood/min (HCT=32) Temperature/flow 30 to 600C / 300 to 800ml/min Hot Rinse (recircula�on 30 to 850C / 300 to 800ml/min Hot disinfec�on with chemical 30 to 850C/ 300 to 800ml/min Various program combina�on selectable

  4. Dialysis Machine AM-DM41 Parameter Displayed UF goal, UF �me, UF rate, UF volume Blood Leak Detector Sensi�vity ≤0.35 mL blood/min (HCT=32) Applica�ons  These are widely used in hospitals, clinics and nursing homes