1 / 11

NetApp NCDA ONTAP NS0-162 Real Questions

PassQuestion provides high quality NetApp NCDA ONTAP NS0-162 Real Questions which cover all the questions that you will face in the Exam Center. It covers the latest pattern and topics that are used in Real Test.

Download Presentation

NetApp NCDA ONTAP NS0-162 Real Questions

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NS0-162 Free Questions NS0-162 Free Questions NetApp Certified Data Administrator, NetApp Certified Data Administrator, ONTAP ONTAP https://www.passquestion.com/ https://www.passquestion.com/NS0-162 NS0-162.html .html

  2. Question 1 Question 1 You currently have an 8-node cluster and want to perform a rolling upgrade to a newer You currently have an 8-node cluster and want to perform a rolling upgrade to a newer version of ONTAP to solve security issues reported in the Active IQ Web site. version of ONTAP to solve security issues reported in the Active IQ Web site. In this scenario, which two steps should you validate before you perform the upgrade? In this scenario, which two steps should you validate before you perform the upgrade? (Choose two.) (Choose two.) A. Run Active IQ Config Advisor. A. Run Active IQ Config Advisor. B. Validate Nodes with Hardware Universe. B. Validate Nodes with Hardware Universe. C. Validate Nodes with Active IQ Unified Manager. C. Validate Nodes with Active IQ Unified Manager. D. Run Upgrade Advisor Report. D. Run Upgrade Advisor Report. Answer: AD Answer: AD

  3. Question 2 Question 2 When performing a manual MetroCluster switchover, which two statements are true? When performing a manual MetroCluster switchover, which two statements are true? (Choose two.) (Choose two.) A. Only the user specified DR groups are switched over. A. Only the user specified DR groups are switched over. B. All SVMs in the disaster site are switched over. B. All SVMs in the disaster site are switched over. C. All DR groups in the disaster site are switched over. C. All DR groups in the disaster site are switched over. D. Only the user specified SVMs are switched over. D. Only the user specified SVMs are switched over. Answer: CD Answer: CD

  4. Question 3 Question 3 Which two statements about replicating FlexGroup volumes are true? (Choose two.) Which two statements about replicating FlexGroup volumes are true? (Choose two.) A. You can increase the capacity of a FlexGroup volume that is being replicated. A. You can increase the capacity of a FlexGroup volume that is being replicated. B. The SnapMirror relationship type must be XDP. B. The SnapMirror relationship type must be XDP. C. You cannot perform a resync on a FlexGroup SnapMirror relationship after it has been broken. C. You cannot perform a resync on a FlexGroup SnapMirror relationship after it has been broken. D. The SnapMirror relationship type must be DP. D. The SnapMirror relationship type must be DP. Answer: AC Answer: AC

  5. Question 4 Question 4 What are two advantages of creating small RAID groups inside an aggregate? (Choose two.) What are two advantages of creating small RAID groups inside an aggregate? (Choose two.) A. maximized storage space A. maximized storage space B. decreased risk of multiple disk failure B. decreased risk of multiple disk failure C. shorter reconstruction time C. shorter reconstruction time D. additional available spare drives D. additional available spare drives Answer: BD Answer: BD

  6. Question 5 Question 5 When a write from a SAN host is received, the information is stored within the controller before it is When a write from a SAN host is received, the information is stored within the controller before it is written to the underlying RAID. written to the underlying RAID. In this scenario, which component stores the data? In this scenario, which component stores the data? A. NVRAM A. NVRAM B. Flash Pool B. Flash Pool C. HBA C. HBA D. FlashCache D. FlashCache Answer: A Answer: A

  7. Question 6 Question 6 Which two features are supported on NetApp ONTAP? (Choose two.) Which two features are supported on NetApp ONTAP? (Choose two.) A. SnapMirror A. SnapMirror B. FlexCache B. FlexCache C. Fibre Channel C. Fibre Channel D. Storage Pool D. Storage Pool Answer: AB Answer: AB

  8. Question 7 Question 7 You created a new SVM with two NFS data volumes. You have a Linux host on You created a new SVM with two NFS data volumes. You have a Linux host on the same subnet as the SVM that is able to NFS mount, however a Linux host on the same subnet as the SVM that is able to NFS mount, however a Linux host on a different subnet is not able to NFS mount. a different subnet is not able to NFS mount. You confirmed that the export policy rules are correct. You confirmed that the export policy rules are correct. In this scenario, which configuration will solve the mount failure? (Choose the In this scenario, which configuration will solve the mount failure? (Choose the best answer.) best answer.) A. The NFS server is not configured on the SVM. A. The NFS server is not configured on the SVM. B. NTP is not configured on the SVM. B. NTP is not configured on the SVM. C. NFS auditing is not enabled on the SVM. C. NFS auditing is not enabled on the SVM. D. The SVM default network route is missing. D. The SVM default network route is missing. Answer: D Answer: D

  9. Question 8 Question 8 Which ONTAP feature uses the Service Processor to speed up takeover times between HA pairs? Which ONTAP feature uses the Service Processor to speed up takeover times between HA pairs? A. hardware-assisted takeover A. hardware-assisted takeover B. automatic takeover and giveback B. automatic takeover and giveback C. epsilon C. epsilon D. cluster HA D. cluster HA Answer: A Answer: A

  10. Question 9 Question 9 Node A has taken over Node B. You solved the issue that caused the takeover and are now ready to Node A has taken over Node B. You solved the issue that caused the takeover and are now ready to resume normal operation. resume normal operation. After initiating the storage failover giveback command, how are the aggregates given back? (Choose After initiating the storage failover giveback command, how are the aggregates given back? (Choose the best answer.) the best answer.) A. CFO aggregates are automatically given back, SFO aggregates must be manually given back. A. CFO aggregates are automatically given back, SFO aggregates must be manually given back. B. CFO aggregates and SFO aggregates are automatically given back. B. CFO aggregates and SFO aggregates are automatically given back. C. The root aggregate is automatically given back, CFO and SFO aggregates must be manually given C. The root aggregate is automatically given back, CFO and SFO aggregates must be manually given back. back. D. SFO aggregates are automatically given back, CFO aggregates must be manually given back. D. SFO aggregates are automatically given back, CFO aggregates must be manually given back. Answer: B Answer: B

  11. Question 10 Question 10 You need to move a FlexVol volume from one SVM to another. You need to move a FlexVol volume from one SVM to another. In this situation, which command would accomplish this task? In this situation, which command would accomplish this task? A. volume create A. volume create B. volume rehost B. volume rehost C. volume modify C. volume modify D. volume move D. volume move Answer: B Answer: B

More Related