1 / 33

化工廠工程控制的原則

化工廠工程控制的原則. 替代 substitution: 用焊接管代替 flanged pipes; 用毒性低的溶劑 ; 用水作為熱媒代替油等 減輕 attenuation: 降低溫度壓力,例如使用觸媒,減壓蒸餾等 隔離 isolation: 控制室與操作現場隔開,危險性設備與化學品放在特別房間內等 減量 intensification: 改用小型反應器,減少庫存等 包圍 enclosure: 將整個設備包起來,用氣體輸送法輸送有害粉塵等 局部換氣 local ventilation: 控制有害物產生區的環境氣氛. 化工廠工程控制的原則 (2).

gloria
Download Presentation

化工廠工程控制的原則

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 化工廠工程控制的原則 • 替代substitution: 用焊接管代替flanged pipes; 用毒性低的溶劑; 用水作為熱媒代替油等 • 減輕 attenuation: 降低溫度壓力,例如使用觸媒,減壓蒸餾等 • 隔離isolation: 控制室與操作現場隔開,危險性設備與化學品放在特別房間內等 • 減量intensification: 改用小型反應器,減少庫存等 • 包圍enclosure: 將整個設備包起來,用氣體輸送法輸送有害粉塵等 • 局部換氣local ventilation: 控制有害物產生區的環境氣氛

  2. 化工廠工程控制的原則(2) 7. 稀釋通風dilution ventilation: 期望降低有害物濃度,配合過濾系統除去有害物 8. 濕法wet methods: 減少粉塵影響,使用 water spray等 9. 好的管理good housekeeping: 設計清洗系統 (用水或蒸汽), 設計良好的排水系統,可供緊急情況下使用 10. 個人保護: 最後一道防線

  3. 工業通風Industrial Ventilation • 簡單的說就是整體換氣(displacement ventilation)與局部排氣(local exhaust)兩種工程,其目的在於控制作業環境中的有害物或危險物的濃度,使在限制數值之下。 • 整體換氣: 是以新鮮的空氣稀釋被污染的空氣,希望改善室內的空氣品質(indoor air quality) [除污染物外,也要考慮溫度及濕度] • 整體換氣比較不適合: 氣味及粉塵的控制,因為二者的擴散能力強,所以需要的新鮮空氣量大,增加成本。

  4. 換氣量計算 • 依室內人數計算: • 每小時換氣量 m3/hr = 人數 x 每個人每小時換氣量 •  例如勞委會的規定: • 工作場所每一勞工所佔m3每一勞工所需新鮮空氣m3/min • < 5.7 0.6以上 • 5.7 < <14.2 0.4以上 • 14.2 < <28.3 0.3以上 • >28.3 0.14以上

  5. 換氣量計算 (2) 2. 依室內容積計算:  每小時換氣量 = 室內容積 (m3) x 每小時換氣次數 (1/hr) 場所種類 換氣次數 工廠 一般作業室 6 塗裝室 20 發電變電室 20 一般建築 事務室 6 會議室 12 有害氣體塵埃發出的地方 20以上

  6. 換氣量計算 (3) • 依據液體蒸發速率,TLV值計算換氣量,適用於毒性物質: •  換氣量 (m3/min) = {1446 x 溶劑比重 x 106 x 蒸發率 (kg/sec) x K}/(溶劑分子量 x TLV); • K 為安全係數,取3-10之間,依TLV值大小建議如下: • TLV (ppm) >500 500 400 300 200 100 <100 • K 3 4 5 6 8 9 10

  7. 換氣量計算(4) 對可燃液體而言,依據其蒸發量以及LEL計算之: 換氣量 (m3/min) CMM = {1446 x 溶液比重 x 100 x 蒸發率 (kg/sec)}/(分子量 x {LEL x C} x B} 其中B=1 當溫度不高於250oF; B=0.75, 當溫度高於250oF C=25% for一般作業; C=1 – 0.5% for 特殊危害控制情況 LEL: lower explosive limit 燃燒或爆炸下限,一般作業控制在該值的25%處,特殊危害物質作業時,則降低到1 – 0.5%。

  8. 依有機溶劑中毒預防規則計算 溶劑種類 換氣量 CMM 第一種溶劑 作業時間一小時內消費量 (g/hr) x 0.3 第二種溶劑 作業時間一小時內消費量 (g/hr) x 0.04 第三種溶劑 作業時間一小時內消費量 (g/hr) x 0.01 * 適用於單純的有機溶劑或其混合物

  9. 計算範例 • 對象: 乙酸異丙酯- 基本數據 TLV 250ppm; MW=102; 作業空間: 9.3m x 9m x 3.3 m; 飽和蒸汽壓 = 47.5 mmHg (作業溫度下); 第二類有機溶劑; LEL = 1.8%; 比重 = 0.87; 蒸汽密度 = 3.52 kg/m3 • 先估計蒸發速率, 得到5.45 x 10-4 kg/sec • 然後使用不同的方法,估算換氣量: 結果得到 TLV法 = 142.8 CMM; LEL 法 = 3.73 CMM 室內容積法 = 138.1; 有機溶劑中毒預防規則 = 78.5 CMM  理論上應該選取最大的數值,也就是142 m3/min, 作為換氣量工程設計使用。

  10. Evaluation of Worker Exposure to Toxic Vapors l Material balance viewpoint: V dC/dt = Qm – k Qv C Where Qm = source term (evaporation rate of toxic vapor) (mass/time) Qv = ventilation rate (volume/time) k = nonideal mixing factor (=1 for ideal mixing) l At steady state, we get Cppm = Qm RT/(k Qv P M) x 106

  11.  Qm = M K A (Psat – P)/(RT) * K = mass transfer coefficient To estimate K roughly  K = a D2/3 * D is the diffusion coefficient; a = proportional constant For gases: D/Do = (M/Mo)1/2; Do a reference diffusion coefficient  or K = Ko (M/Mo)1/2; Ko is a reference mass transfer coefficient

  12. 其他注意事項 • 排氣管內,要避免有機蒸汽的累積,避免引起火災 (方法之一為增設活性碳的設備,但必須注意活性碳吸附床的保養維修) • 科學園區的半導體廠,曾經因為廢氣的排氣管中,通入不相容的氣體,最後導致火災 • 抽氣量大,可能造成作業環境的溫度下降,也許對製程並不好的效果  需要折中處理 (在製程,環保,安全中,選擇最適化的作業條件)

  13. 人的呼吸 • 進入大型儲槽維修(or 類似情況),其內的氧氣夠不夠? 基本資料: 正常人的肺部體積5 L, 每次約呼吸500 ml, 其中僅350 ml與肺部交換,呼吸速度約30 L/min (I.e. 每秒一次),肺部內氧氣濃度約16%; • 人類吸入16%氧的空氣,就會發生不適應現象; 當氧氣濃度降到11-12%, 就會昏迷,6%呼吸停止 • 如果進入純氮容器內工作,又未攜帶空氣鋼瓶,吸幾口氣後就會昏迷? 多久會死亡? • V dy/dt = - m’ y (m’ = 30 L/min; V = 5 L; t =0, y = 0.16) • 解之,當y = 11%時,t = 6.9 sec 會昏迷 • 當 y = 6%, t = 17.9 sec 會死亡

  14. 缺氧狀態的症兆 氧氣含量 症 兆 12-14% 呼吸深沈,脈搏加速,手腳不協調 10-12% Cheyne-Stokes 呼吸(?),昏眩,poor judgement, 嘴唇變藍 8 – 10% 昏睡感,嘔吐,昏迷,臉泛紅 6 –8% 8 min 100%的生物都會死亡; 6 min 可以救回一半; 4-5 mn 大部分都能救回 4 % 40 sec就昏迷,抽慉,呼吸停止,死亡

  15. 利用電腦模擬計算換氣量 • 以上諸公式,明顯的僅為依據經驗得到,所以不會太精確。若能利用我們對流體力學的知識,模擬作業環境內的流場,物質分佈,乃至於溫度,濕度分佈都可以得到,如此將更有助於精確的設計換氣量,不至於過大或不足。 • 工研院經驗: 可用於噴漆作業,造漆作業,或噴砂作業等所需要的氣流亭設計。

  16. 氣流亭模組單元設計的流程圖

  17. 污染物隨著這氣流穿過右下方百葉槽縫進入過濾區,而被濾除。氣流亭的概念污染物隨著這氣流穿過右下方百葉槽縫進入過濾區,而被濾除。氣流亭的概念

  18. 模組化氣流亭為有效的控制手段。取自工安環保報導第四期模組化氣流亭為有效的控制手段。取自工安環保報導第四期

  19. 氣流亭模組實體及其面速測試

  20. 局部排氣 • 其設計步驟包括: • 氣罩設計: 如上吸,下吸,側吸,吹吸等不同的方式,在最恰當高度,以最經濟風量捕集有害物質 • 管路設計: 計算各段的風管壓損,及壓力平衡 • 尾氣處理設計: 適合排氣成分的處理設備,例如集塵,濕式洗滌塔,活性碳塔等 • 風車: 計算排氣量以及系統的靜壓損

  21. 輸送速度的範圍 有害物 輸送風速 (m/min) 蒸汽,氣體,煙 305 - 370 燻煙fume 427 - 610 非常輕細粉塵 610 - 762 乾粉塵 762 - 1070 重粉塵 1220 - 1370 重或潮濕粉塵 >1370

  22. 9m 活性碳 吹吸式局部排氣設計示意圖。使用理由: 該廢水槽區,污染源面積廣,且風車換氣量有限,因此改為吹吸式,可以不必大幅增加換氣量,節省一些成本。

  23. 打粉機的示意圖。作業期間會造成粉塵溢出的幾個地方:打粉機的示意圖。作業期間會造成粉塵溢出的幾個地方: • A處,儲槽下料的地方 • B處,抽風口 • C處,打完粉後,下料到另一個儲槽 • 個別設計小型的局部抽氣罩,解決粉塵問題。

  24. 排風機,進氣口位置之良莠探討

  25. 理想的設計,都是希望避免污染的空氣接觸到操作人員理想的設計,都是希望避免污染的空氣接觸到操作人員

  26. 氣罩分類 • 包圍型: 一般排氣量較低,效果高,例如覆蓋型,套箱型(glove box), 崗亭式,建築崗亭型等, • 外裝式氣罩: 例如側邊型氣罩,懸吊型全面開口氣罩,懸吊型三面開口氣罩,底邊型氣罩; 側向吸引型,下向吸引型,上向吸引型等

  27. 實驗室則多使用抽風櫃,以控制作業場所有害物或危險物的濃度實驗室則多使用抽風櫃,以控制作業場所有害物或危險物的濃度 圖片取自Labsafety series

  28. 普通的抽風櫃,內部氣體流量與速度分佈,會受開關的大小影響普通的抽風櫃,內部氣體流量與速度分佈,會受開關的大小影響

  29. 可採取by-pass設計。理想狀況是所有的危險物及有害物都會被立即帶走,處理後排放。不宜有eddy current, 將可能造成殘留有害物在氣櫃內。

  30. Glove Box * 取自chemical engineering, p.66, April, 2002;