An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Commercial Building Disclosure Accredited Assessor Training Course - Lighting May 2012

  2. Housekeeping • Duration • Breaks • OH&S • Evacuation • Turn off mobile phones

  3. Course coverage • About CBD Lighting Assessments • Understanding the rules • The assessment form • Example assessments • Assessing your knowledge

  4. Topic 1About CBD Lighting Assessments

  5. What is the CBD program • The CBD program is the initiative of the Australian and State/Territory Governments. • The program was established under the Building Energy Efficiency Disclosure Act 2010. • Designed to improve the energy efficiency of Australia’s larger office buildings.

  6. CBD Administration • National program • Managed by the Australian Government Department of Climate Change and Energy Efficiency

  7. Objective of the CBD program • The aim is to minimise asymmetric information between buyers and sellers about the relative energy efficiency of large office buildings that are for sale or lease. • This information empowers the market with information that will encourage energy efficiency improvements. • Twin impacts – better price for efficient buildings, and lower greenhouse gas impacts.

  8. What is Building Energy Efficiency Certificate • Under the Building Energy Efficiency Disclosure (BEED) Act 2010, • A Building Energy Efficiency Certificate (BEEC) is required for sale, lease or sub-lease office space of 2,000m² or more. • The BEEC is comprised of three parts • Part 1 - A base building NABERS rating • Part 2 - A Tenancy Lighting Energy Efficiency Assessment • Part 3 - Energy efficiency guidance for building owners and tenants

  9. What is a CBD Tenancy Lighting Assessment? • An assessment of the energy efficiency of office lighting systems • Lighting power density • General lighting only and not tenant feature lighting • Nominal – not the same as BCA Part J6 • Control capacity • No judgment on effectiveness • Doesn’t assess actual consumption • What it can do – not how it is currently used

  10. Why have the assessments? • Provide information to prospective tenants or owners about the efficiency of the system • Affects cost to run of different spaces • Affects NABERS Tenancy Energy ratings. • Incentivise owners / tenants to upgrade inefficient lighting systems

  11. Guiding principles • Fair comparison between tenancies • Robust and repeatable • Cost effective and timely

  12. Extract from sample BEECBEEC – Cover page • Building details • Assessor details • NABERS Rating • Lighting Assessment coverage

  13. Extract from sample BEECBEEC – Part 1 • NABERS Rating detail • Assessment of base building energy performance

  14. Extract from sample BEEC BEEC – Part 2 • Assessment of general Tenancy Lighting system efficiency • Power density • Control capacity • Note: Base building lighting efficiency covered by NABERS rating

  15. Extract from sample BEECBEEC – Part 3 • Generic energy efficiency guidance • Same information for all BEECs

  16. Who can do a Tenancy Lighting Assessment • Accredited CBD assessor • Check the CBD website www.cbd.gov.au • Training requirements • Must be a NABERS assessor • Must have completed a supervised NABERS energy for offices rating • Attend this session and pass the accreditation exam • Pass the Commercial Building Disclosure program module

  17. Processes and procedures • Customer • Agree fee • Obtain information • Tenants • Negotiate access • Security and OH&S • Follow all site and tenant induction and OH&S requirements • Have general and site specific safe work methods statements

  18. Lighting Assessment process • Site inspection • Fill out the Tenancy Lighting Assessment (TLA) form • Ensure all required information has been filled • Submit TLA form to CBD team • Auditing of application • Issue of TLA assessment number

  19. Assessment timing • Lodge assessment within 4 months of assessment date (1st day of site inspection) • Up to 28 days to process the Tenancy Lighting Assessment form • Up to 28 days to process the BEEC application • Inform clients of processing timeframes

  20. Record keeping processes • Retain records for seven years • Retain primary data from assessment • Site photos notes and marked up drawings • Leases or contractual agreements used in assessments • Summary data only is not acceptable • Must be sufficient for an assessor / auditor to repeat accurately the assessment from documentation only • All evidence needs to be provided to the CBD administrator upon request

  21. Record keeping processes • Logical filing of evidence is essential • Poor documentation is the primary cause for failing audits • Lighting assessments can be audited even seven years after the BEEC has been issued

  22. Administrative processes • Submission requirement • 4 months from date of first inspection to submission • Validity of assessment • Valid for 12 months from certification date • Interpretation of rules – CBD administrator • Dispute resolution • With client • With CBD administrator

  23. Topic 2Understanding the rules

  24. Functional spaces • Break areas to assess into separate functional spaces • Separate assessment per functional space • Acceptable names for a functional space:- Level 1, West Tenancy- Level 2, Whole Floor- Level 10, East • Not acceptable functional space names:- 10 or 12.03- Open office- Suite 103

  25. Functional space area • Maximum size is the smaller of: • Whole tenancy; or • Whole floor • Can define functional spaces to be the same as used for the NABERS rating • NLA required for the whole functional space • NLA to give perspective but not critical • Areas already required for NABERS rating so should be available

  26. Naming functional spaces - example • This is on level 2 of the building • Use names of: • Level 2 Suite 1 • Level 2 Suite 2

  27. General lighting system • In place when tenant moves in • Remains when tenant leaves and makes good • Not desk-top task lighting • Not feature lighting • Conference rooms • Reception

  28. General lighting system • Do not assess the quality of luminaires • Poor optics • Dirty / old • Failed lamps • Do not assess the quantity of light • Low lux levels • Dark areas

  29. General lighting system - example • Included • Troffers • Excluded • Exit lights • Up lights

  30. General lighting system identification

  31. Group exercise – identify the general lighting system • Work in a group, identify the general lighting system from the photos and plans provided • You have 15 minutes

  32. General lighting system exercise 1

  33. General lighting system exercise 2

  34. General lighting system exercise 3

  35. General lighting system exercise 3a

  36. General lighting system exercise 4 1200x600 grid

  37. General lighting exercise 5 1200x600 grid

  38. Nominal Lighting Power Density

  39. Nominal Lighting Power Density • Four categories: • “Poor” >15W/m² • “Median” 10.1-15W/m² • “Good” 7-10.0W/m² • “Excellent” <7W/m²

  40. Identifying luminaires • Definition of terms • Luminaire naming conventions • Counting lamps • Determining nominal lamp power

  41. Luminaire naming conventions • Suggested option • XXabb • XX is a luminaire body code (2 or more letters) • a is the number of lamps (single digit number) • bb is the nominal power of each lamp - typically 2 digits but may be 3 or more • If you need more information, precede with a plus sign • RT236 is a 2x36W recessed troffer • RT236 + LVR for louvred diffuser

  42. Luminaire naming conventions • Suggested option • XXabb • XX is a luminaire body code (2 or more letters) • a is the number of lamps (single digit number) • bb is the nominal power of each lamp - typically 2 digits but may be 3 or more • If you need more information, precede with a plus sign • RT236 is a 2x36W recessed troffer • RT236 + LVR for louvred diffuser

  43. Counting lamps • Must physically sight the lamps • Diffusers and reflectors can give misleading lamp images • Luminaire on the right has a single T8 lamp

  44. Determining lamp power • Use the nominal lamp power • Written on the lamp’s tube or base • Where unsafe to inspect use nominal 50W lamp power for halogen downlights

  45. Luminaire control gear fundamentals • Identifying ballast types • Identifying transformer types • Determining luminaire power

  46. Identifying Ballast Types • Using the ballast discriminator • T5 – electronic only • Looking up lamp model • Inspecting lamp connection

  47. Identifying Transformer Types • Visual inspection • Magnetic – larger, heavier • Smaller – details written on transformer • Ballast discriminator with care • If pointed at transformer (not lamp) • Provided ceiling/obstructions aren’t too strong

  48. Total luminaire power • Standardized figures only – NLP may differ from actual power NLP = nominal lamp power

  49. Other luminaires • For luminaire types not scheduled eg • LED • T5 adapters • Directly measure luminaire power or take from nameplate • Ensure safe work methods are followed • Engage specialist trades person if required

  50. T5 adapters