Patricia Aguar Bartolomé

Status of the Polarized 3 He Target . Patricia Aguar Bartolomé. Overview. Magnetic Holding Field - Solenoid design - Numerical calculations - Solenoid test Target Cell Preparation Measurement of Polarization

haracha
Download Presentation

Patricia Aguar Bartolomé

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of the Polarized 3He Target Patricia AguarBartolomé

  2. Overview • Magnetic Holding Field • - Solenoid design • - Numerical calculations • - Solenoid test • Target Cell Preparation • Measurement of Polarization • - Mechanical rail system • - External holding field Patricia AguarBartolomé

  3. Magnetic Holding Field Polarized targets require a magnetic holding field, B0, to provide a quantization axis. SOLENOID The strength and uniformity of the field play an important role in obtaining long polarization relaxation times. Depolarization effects due to field gradients should be smaller than the relaxation due to surface effects. • Main constraints • Produce magnetic holding field of 7G with a relative field gradient of 10-3 cm-1for 6 bars in the target cell area. • Appropriate outer radius to fit inside the Crystal Ball detector. • Target cell dimensions determine the inner radius. • The outgoing particles have to pass the coil minimization of the wire thickness. Patricia AguarBartolomé

  4. Magnetic Field Calculation • Numerical calculation of the field and gradients with a finite • element code (FEMM) • Geometric parameters for the solenoid • Coil wound on a CFK-tube with cross section of 82 x 1 mm2 and 120 cm • length. • B magnitude determined using the three axis magnetometer MAG-03 MS • (Bartington Instruments Ltd.) Patricia Aguar Bartolomé

  5. Solenoid Test Patricia AguarBartolomé

  6. Target Cell Design • 20 cm length and 6 cm diameter • Non-magnetic materials in order to avoid depolarization of the gas • - Quartz glass cell coated with Cesium • - Aluminum caps • - 50 mm Mylar windows metalized with Aluminum • 3He gas target (P = 6 bar) • First tests with prototype are in process Patricia AguarBartolomé

  7. First T1 Measurement With Uncoated Cell Patricia AguarBartolomé

  8. Measurement of Polarization Mechanical rail system to transport the target cell from the center of the solenoid to the center of the external holding field 2) 1) 3) 4) Patricia AguarBartolomé

  9. External Holding Field Helmholtz coils needed to measure the polarization Patricia AguarBartolomé

  10. Transporting Solenoid Solenoid to bring the target cell from the center of the CB to the center of the Helmholtz coils. Patricia AguarBartolomé

  11. Summary and outlook • Conclusions • A solenoid produced to provide the holding field for the 3He target was • designed and tested • First homogeneity measurements of the solenoid with the polarized gas • give values of • First measurement of T1 with uncoated cell gives 4h • Future • Fix the leak on the target cell prototype • Measurement of T1 with coated cell • Production of mechanical rail system Patricia AguarBartolomé