Lumio - Confidential

Crystal Touch Panel Assembly Training Course. 1.14 Trouble shooting. Each PCB controller contains a Serial number label. Each glass panel contains a serial number label.

henrykarl
Download Presentation

Lumio - Confidential

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Crystal Touch Panel Assembly Training Course 1.14 Trouble shooting Each PCB controller contains a Serial number label. Each glass panel contains a serial number label. Ensure that the serial numbers on the PCB and on the glass panel match. Mismatch causes touch event error, boundaries will need to be readjusted and the system will need to be re- calibrated. Boundaries errors can lead to calibration error or to the first few points not being calibrated. It is your responsibility is to inform integrators, verbally and in writing (when delivering the system) about the above issues. Lumio - Confidential

  2. Crystal Touch Panel Assembly Training Course 1.14 Trouble shooting • Check the flat cable connection to the sensor and the PCB Controller. • Check that the Rod Holder does not cover the sensor lens.

  3. Crystal Touch Panel Assembly Training Course 1.14 Trouble shooting No Touch? For Win7: • Check that pen and touch is available. • Check the Human Interface Devices in Device Manager .

  4. Crystal Touch Panel Assembly Training Course 1.14 Trouble shooting • No Touch? • Open CTM and check the CTM and Firmware versions. • Open Scope and check that the boundaries are o.k. • Check properties and perform calibration.

  5. Crystal Touch Panel Assembly Training Course 1.14 Trouble shooting TN 001 – WIN 7 Calibration error message • Some security settings (permissions) changes are required when using • WIN 7 O.S. as a platform for the Crystal Touch Manager application. • 1. Select the C.T.M. icon on the Desktop. • 2. Right Click on the Crystal Touch Manager icon and choose properties. • 3. The properties window appears. • 4. Select the Compatibility tab. • 5. Click the Change settings for all users tab. • 6. The Change settings for all users opens. • 7. Enable the Run this program as an Administrator in the Privilege Level. • 8. Click on Apply. • 9. Click on OK.