Reaction Engineering. Minibioreactors. -> Volumes below 100 ml Characterized by: -> area of application -> mass transfer -> mixing characteristics. Minibioreactors. Why do we want to scale down ? - Parallelization (optimization, screening) automatization cost reduction

hua
Download Presentation

Reaction Engineering

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Reaction Engineering

  2. Minibioreactors -> Volumes below 100 ml Characterized by: -> area of application -> mass transfer -> mixing characteristics

  3. Minibioreactors • Why do we want to scale down ? • - Parallelization (optimization, screening) • automatization • cost reduction • What can you optimize? • Biocatalyst (organism) design • medium (growth conditions) design • process design

  4. Minibioreactors • shake-flasks • microtiter plates • test tubes • stirred bioreactors • special reactors

  5. Minibioreactors Shaking flasks: -> easy to handle -> low price -> volumne 25 ml – 5 L (filled with medium 20% of volumne) -> available with integrated sensors (O2, pH) -> limitation: O2 limitation (aeration) -> during growth (improved by 1. baffled flasks 2. membranes instead of cotton -> during sampling

  6. Minibioreactors Microtiter plates: -> large number of parallel + miniature reactors -> automation using robots -> 6, 12, 24, 48, 96, 384, 1536 well plates -> volumne from 25 μl – 5 ml -> integrated O2 sensor available Increased throughput rates allow applications: - screening for metabolites, drugs, new biocatalysts (enzymes) - cultivation of clone libraries - expression studies of recombinant clones - media optimization and strain development

  7. Minibioreactors Microtiter plates: -> Problems: - O2 limitation (aeration) -> faster shaking -> contamination - cross-contamination - evaporation -> close with membranes - sampling (small volumne -> only micro analytical methods + stop shaking disturbs the respiration)

  8. Minibioreactors Test tubes: -> useful for developing inoculums -> screening -> volumne 2 -25 ml (20% filled with medium) -> simple and low costs -> O2 transfer rate low -> usually no online monitoring (pH and O2) -> interruption of shaking during sampling

  9. Minibioreactors Stirred Systems: -> homogeneous environment -> sampling, online monitoring, control possible without disturbance of culture -> increased mixing (stirring) + mass transfer (gassing rate)

  10. Minibioreactors Stirred Systems – Stirred Minibioreactor -> T, pH, dissolved O2 can be controlled -> Volumne from 50 ml – 300 ml -> small medium requirenments -> low costs (isotope labeling) -> good for research -> good for continous cultivation -> Limitation: - system expensive due to minimization (control elements) - not good for high-throughput applications

  11. Minibioreactors Stirred Systems – Spinner flask -> designed to grow animal cells -> high price instrument -> shaft containing a magnet for stirring -> shearing forces can be too big -> side arms for inoculation, sampling, medium inlet, outlet, ph probe, air (O2) inlet, air outlet -> continous reading of pH and O2 possible

  12. Minibioreactors Special Devices – Cuvette based microreactor -> optical sensors (measuring online: pH, OD, O2) -> disposable -> volumne 4 ml -> air inlet/outlet -> magnet bead -> stirring -> similar performance as a 1 L batch reactor

  13. Minibioreactors Special Devices – Miniature bioreactor with integrated membrane for MS measurement: -> custom made -> expensive -> a few ml -> online analysis of H2, CH4, O2, N2, CO2, and many other products, substrate,... -> used to follow respiratory dynamics of culture (isotope labeling) -> stirred vessel with control of T, O2, pH -> MS measurements within a few seconds to minutes -> continous detection -> fast kinetic measurements, metabolic studies

  14. Minibioreactors Special Devices – Microbioreactor: -> Vessel 5 mm diameter round chamber -> Really small working volumne -> 5 μl -> integrated optical sensors for OD, O2, pH -> made out of polydimethylsiloxane (PDMS) -> transparent (optical measurements), permeable for gases (aeration) -> E. coli sucessfully grown -> batch and continous cultures possible -> similar profile as 500 ml batch reactors -> limitation: sampling (small volumne -> analytical methods !!!)

  15. Minibioreactors NanoLiterBioReactor (NLBR): -> used for growing up to several 100 mammalien cells -> culture volumne around 20 μl -> online control of O2, pH, T -> culture chamber with inlet/outlet ports (microfluidic systems) -> manufactured by soft-lithography techniques -> made out of polydimethylsiloxane (PDMS) -> transparent (optical measurements), permeable for gases (aeration) -> direct monitoring of culture condition -> PDMS is transparent -> flourescence microscope -> limitation: batch culture very difficult-> too small volumne -> suffers from nutrient limitation -> But in principle system allows -> batch, fed-batch, continous

  16. Minibioreactors NanoLiterBioReactor (NLBR): Circular with central post (CP-NBR) Chamber: 825 μm in diameter Volumne: 20 μl Perfusion Grid (PG-NBR) Similar Volumne Incorporated sieve With openings 3-8 μm -> small traps for cells Multi trap (MT-NBR) larger Volumne Incorporated sieve Opening similar -> multi trap system -> Seeding was necessary (Introduction of cells into chamber) -> 30 μm filtration necessary -> to prevent clogging in the chamber (aggregated cells) -> Flow rate of medium: 5-50 nl/min

  17. Minibioreactors NanoLiterBioReactor (NLBR):

  18. Minibioreactors NanoLiterBioReactor (NLBR):

  19. Minibioreactors • Why do we want micro-and nano reactors? • Applications in: • Molecular biology • Biochemistry • Cell biology • Medical devices • Biosensors • > with the aim to look at single cells !!!

  20. Minibioreactors Micro/Nanofluidic Device for Single cell based assay: -> used a microfluidic chip to capture passively a single cell and have nanoliter injection of a drug

  21. Minibioreactors Micro/Nanofluidic Device for Single cell based assay: -> used a microfluidic chip to capture passively a single cell and have nanoliter injection of a drug Microchannel height: 20 μm (animal cells are smaller than 15 μm in diameter) -> If channel larger than 5 μm in diameter -> hydrophilic -> if channel smalles than 5 μm in diameter -> hydrophobic Gray area is hydrophobic -> air exchange possible -> no liquide (medium) can leak out