1 / 23

Shaobin Guo 11/20/2012

Shaobin Guo 11/20/2012. various types of Single-molecule force spectroscopy. Optical tweezers Magnetic tweezers Atomic force microscopy (AFM) Micro-needle manipulation Biomembrane force probe Flow-induced stretching. Single-molecule manipulation capacity.

ishana
Download Presentation

Shaobin Guo 11/20/2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Shaobin Guo • 11/20/2012

  2. various types of Single-molecule force spectroscopy • Optical tweezers • Magnetic tweezers • Atomic force microscopy (AFM) • Micro-needle manipulation • Biomembrane force probe • Flow-induced stretching

  3. Single-molecule manipulation capacity • Length: 10-10 - 10-4 m / measurement of RNA polymerase advancing a single base pair to manipulation of cells • Force: 10-14 - 10-8 Newton / assaying nucleic acid folding kinetics to mechanical disruption of covalent bonds

  4. Optical tweezers (Trap) • Lasers: near-infrared wavelengths (800-1100 nm) • High numerical aperture (NA) microscope objective (at least 1.2) • An approximate linear spring for small displacements (~150 nm) • Position detection: back-focal plane (BFP) interferometry • Calibration: position detector and trap stiffness

  5. Infrared laser silica bead kinesin molecule microtubule Infrared laser RNA polymerase molecule Infrared laser applications Interaction assay Tethered assay Dumbbell assay

  6. Limitations and Drawbacks • Require optically homogeneous preparations and highly purified samples for high resolution trapping. • Lack selectivity and exclusivity • Local heating • Optical damage • Limited range of applied force (0.1-100 pN) and range of displacement (~150 nm or less)

  7. magnetic tweezers • A pair of permanent magnets • Inverted microscope with a charge-coupled device (CCD) • Able to rotate super-paramagnetic beads ranging from 0.5 to 5 um • Force-clamp property: an effective stiffness on the order of 10-6 pN/nm • Free from sample heating, photodamage and other problems related to optical tweezers • Drawbacks: not versatile, unable to directly measure rotational torque generation, limited to slow and large displacements

  8. Electromagnetic tweezers • Sharp electromagnetic tips • Able to exert forces in excess of 1 nN • Easy to control force and rotation by changing current • Three-dimensional position control • Drawbacks: cumbersome feedback control, sophisticated pole pieces, lack of sensitivity and heating.

  9. Atomic Force microscopy (AFM) • A very high-resolution type of scanning probe microscopy, with demonstrated sub-nm resolution • Able to measure inter- and intramolecular interaction forces with pN resolution • Simple and rapid sample preparation, and the ability to conduct measurements under near-physiological conditions

  10. applications • Study of molecular bond’s rupture: covalent bonds to protein unfolding • Force-clamp spectroscopy by AFM • Investigation of supramolecular assemblies • Combination of AFM imaging with force mapping and spectroscopy to image the surface topology at high resolution and measure the unbinding or unfolding forces at well-defined locations. • High-speed AFM which makes it possible to follow molecular events in real time.

  11. Limitations and Drawbacks • Narrow useful force range resulting from large size and relative high stiffness of the cantilevers • Lack of specificity

  12. Background • Regiospecific thiol-disulfide exchange reactions: electrons are reshuffled between a thiolate and a disulfide bond via an SN2 mechanism that produces a different disulfide and a new thiolate

  13. problems with bulk techniques • Inability to differentiate disulfide isomers • Variations among different techniques used to analyze reactions and subsequent divergent interpretations • Interference from the reverse reaction

  14. Cantilever Tip Piezoelectric scanner experiment set-up Force: 250 pN

  15. 14.5 nm 10 nm Reduction events from polypeptides containing single disulfide bond (I2732–75)8 (I2724–55)8 Predicted extension after the reduction of a disulfide bond

  16. Reduction events from polypeptides containing two disulfide bonds (I272S-S)4

  17. Cleavage of disulfide 32-75 in I272S-S

  18. Pathways available for the reduction of disulfide 24–55 after the reduction of disulfide 32–75

  19. At high concentrations of L-Cys the frequency of the 10 nm steps increases at the expense of the 3 and 8nm steps

  20. Thanks!Questions?

More Related