1 / 35

Multipulse Positive Displacement Flowmeters

MP Series Multipulse Positive Displacement Flowmeters. Multipulse Positive Displacement Flowmeters. Quality & Simplicity in Flow Measurement. Innovative Technologies, Creative Solutions. Multipulse Positive Displacement Flowmeters. MP. Introduction.

jabari
Download Presentation

Multipulse Positive Displacement Flowmeters

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MP Series Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Quality & Simplicity in Flow Measurement Innovative Technologies, Creative Solutions

  2. Multipulse PositiveDisplacement Flowmeters MP Introduction Multipulse Positive Displacement Flowmeters provide: • Pulse or LCD Display • High levels of accuracy and repeatability. • Wide range of liquids from low viscosity solvents and chemicals to viscous oils, greases and food bases. • Low pressure drop allows for economical pump selection or gravity flow applications.

  3. Multipulse PositiveDisplacement Flowmeters MP Principal of Operation Principal of Operation The MP series uses the oscillating - piston principle where the passage ofliquid causes a piston to oscillate smoothly in a circular motion within the measuring chamber. Each piston cycle passes a known volume of liquid from the inlet to the outlet port, magnets in the piston activate the reed switch and the solid state sensor to provide pulse outputs for remote flow, measurement and process control.

  4. Multipulse PositiveDisplacement Flowmeters MP Principal of Operation The diagram below shows the transition of fluid from the Inlet Port through the Measuring Chamber and then out the Outlet Port.

  5. MP Principal of Operation

  6. MP Principal of Operation

  7. Multipulse PositiveDisplacement Flowmeters MP Features/Benefits Low Number of Parts IP67/ Nema 4x FlameproofTerminal Cover Pulse output board with both hall effect and reed switch (intrinsically safe with approved barrier) Body and manifold have nostagnate chambers Free rotating piston is the only moving part Partition

  8. Multipulse PositiveDisplacement Flowmeters MP Outputs Two Pulse Outputs Reed Switch Output - Provides a voltage free contact closure. The reed switch is classed as a 'simple device' and can be used in hazardous areas when connected via an approved intrinsically safe barrier. Square Wave Output - An open collector pulse output produced by a solid state hall effect device. This 3 wire device requires5-24vdc excitation voltage and producesa high resolution square wave output.

  9. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Features • Multipulse Features • 316L stainless steel, aluminium or UPVC construction ( selected Sizes ) • Accuracy +/- 0.5% of rate • Has no stagnate chambers or cavities • Measures low and high viscosity liquids to 1,000,000 cp • No requirement for flow conditioning • Adaptable to hygienic installations • High Pressure models to 5,150 psi (350 bar) • Flameproof or intrinsically safe electronics (optional) • Insensitive to mounting orientation.

  10. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Stainless Steel Models Sizes: 1/2” (15mm) 1” (25mm) 1 1/2” (40mm) 2” (50mm) Material: 316LST.ST body and Manifold Peek or carbon piston and bearing special materials consult factory Flow Ranges: 0.04 - 2.2 GPM (.17-8.3 LPM) 0.5 - 13.2 GPM (2 - 50 LPM) 1.1 - 35 GPM (4.2 - 133.3 LPM) 3.1 - 88 GPM (11.7-333.3 LPM)

  11. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Stainless Steel Models Process Connections: Threaded BSPP/NPT female thread flanged, ANSI/DIN standards Pressure Rating: 740 - 5,150 psi (50-350 Bar) Temperature Rating: -40ºF to +300ºF (-40ºC to +150ºC) for higher temperaturecontact factory Multipulse Outputs: Reed switch, NPN openCollector output standard

  12. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Stainless Steel Models Options: - Explosion Proof or Intrinsically safe operation - Integral or remote high speed preset batch controller - Integral or remote battery power flow rate totaliser with scaled pulse output, analog and flow alarm outputs. Applications: Chemical and allied products, pharmaceuticals, petroleum, deionised water, container filling machines, fuel additives, asphalt, paint, synthetic rubber, latex, detergent and soap, pigments.

  13. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Aluminum Models Sizes: 1/2” (15mm) 1” (25mm) 1 1/2” (40mm) 2” (50mm) Material: Aluminium body and Manifold Peek or carbon piston and bearing special materials consult factory Flow Ranges: 0.04 - 2.2 GPM (.17-8.3 LPM) 0.5 - 13.2 GPM (2 - 50 LPM) 1.1 - 35 GPM (4.2 - 133.3 LPM) 3.1 - 88 GPM (11.7-333.3 LPM)

  14. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Aluminum Models Process Connections: Threaded BSPP/NPT female thread flanged, ANSI/DIN standards(lap joint flanges) Pressure Rating: 300 to 1,200 psi (20-80 Bar) Temperature Rating: -40ºF to +300ºF (-40ºC to +150ºC)for higher temperaturecontact factory Multipulse Outputs: Reed switch, NPN openCollector output standard

  15. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Aluminum Models Options: - Explosion Proof or Intrinsically safe operation - Integral / remote RT rate totalizer. - Integral or remote battery power flow rate totaliser with scaled pulse output, analog and flow alarm outputs. Applications: Metering petroleum products, diesel, fuel oil, hydraulic oil, kerosene, LPG, gasoline, alcohol, solvents, lacquers and selected chemicals.

  16. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP High Pressure Stainless Steel Models Process Connections: Threaded BSPP/NPT female thread flanged, ANSI/DIN standardsspecials consult factory Pressure Rating: Up to 5,150 psi maximum (350 bar) Temperature Rating: -40ºF to +250ºF (-40ºC to +120ºC) for higher temperaturecontact factory Multipulse Outputs: Reed switch, NPN openCollector output standard

  17. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP High Pressure Stainless Steel Models Sizes: 1/2” (15mm) 1” (25mm) 1 1/2” (40mm) 2” (50mm) Material: 316LST.ST and Manifold Peek or carbon piston and bearing Flow Ranges: 0.2-10.0 LPM 2 - 50 LPM 4 - 140 LPM 12-330 LPM Options: - Explosion Proof or Intrinsically safe operation - Integral or remote high speed preset batch controller - Integral or remote battery power flow rate totaliser with scaled pulse output, analog and flow alarm outputs. Applications: Hydraulics, lube oils, mercaptan, petroleum, deionised water, resins, Mek, Ethylene oxide, oil and gas industry, chemical injection.

  18. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP SAP Models Size: 20mm Material: UPVC body and Manifold Carbon filled teflon piston and bearing (uv stabilised PVC) special material consult factory Flow Ranges: 2.0 - 50.0 LPM Process Connections: Threaded BSPP/NPTfemale thread Pressure Rating: 60 psi (4 bar) Temperature Rating: 60 deg C Multipulse Outputs: Reed switch, NPN openCollector output standard Options: - Intrinsically safe operation - Remote high speed preset batch controller - Remote battery power flow rate totaliser with scaled pulse output, analog and flow alarm outputs.

  19. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP SAP Models Applications: MP020P flow meter manufactured from UV stabilized PVC (UPVC) is ideally suited for special applications associated with corrosive fluid such as sodium hypochlorite, acids, photographic solutions or any chemical compatible with UPVC. The MP020P has flow range of 2 – 50 LPM and provides and economical solution for those difficult fluids compared to more expensive magnetic flow meters or Coriollis mass flow meters manufactured from more exotic materials.

  20. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Hygienic Stainless Steel Models Process Connections: Threaded BSPP/NPT female thread Tri-clamp hygienic fittings BS/DIN standards (or equivalent) Pressure Rating: 750 - 1,500 psi (50-100 bar) Temperature Rating: -40ºF to +300ºF (-40ºC to +150ºC) for higher temperaturecontact factory Multipulse Outputs: Reed switch, NPN openCollector output standard

  21. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Hygienic Stainless Steel Models Sizes: 1/2” (15mm) 1” (25mm) 1 1/2” (40mm) 2” (50mm) Material: 316LST.ST body and Manifold Peek or carbon piston and bearing Flow Ranges: 0.2 - 10LPM 2 - 50 LPM 4- 140 LPM 12 – 330 LPM Options: - Explosion Proof or Intrinsically safe operation - Integral or remote high speed preset batch controller - Integral or remote battery power flow rate totaliser with scaled pulse output, analog and flow alarm outputs. Applications: Pharmaceuticals, cosmetics, deionised water, food and beverage, container filing machines, yeast, confectionery, molasses, liquid sugar, mayonnaise, chocolate, dairy products.

  22. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Specifications - 15mm Model Prefix MP015S MP015A MP015H Body Material 316L stainless steel Aluminium 316L stainless steel Nominal Flow Spans* 10 to 100 / 100 to 300 & 300 to 600 lph (2.6 to 160 USgal/hr)*Turndown (flow range) varies in accordance with effective viscosity of metered liquid Accuracy +1% of rate within nominal spansAccuracy over the full flow range is improved to within + /-0.5% when utilisingthe linearisation feature of the optional Trimec RT flow rate totaliser Repeatability Typically +0.1% under steady flow conditions Maximum Pressure 100 Bar (1500 psi) 30 Bar (440 psi) 350 Bar (5150 psi) Temperature Range Three ranges covering operation from -40 to 150o C (-40to 300o F)limited to 80oC (176oF) with integral electronic register Piston Material Carbon filled teflon – option PEEK

  23. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Specifications - 15mm Model Prefix MP015S MP015A MP015H O-ring Material viton, EPR (EPDM), teflon encapsulated viton or nitrile (Buna-N) Reed Switch Output 30vdc maximum voltage, 20mA maximum current Pulse resolution: 200 pulses / litre (760 pulses / US gallon) Open Collector Output 5 to 24vdc (25vdc maximum) 3 wire NPN (sinking current)20mA maximum current - 1000 metres (3300 ft) maximum transmissionPulse resolution: nominally 400 pulses / litre (1520 pulses / US gallon) Electrical Connection M20 x 1.5 or 1/2" NPT female entries Process Connections 1/2" BSPP or NPT1/2" ANSI 150/300RFflangesDN15 PN16 - 40 flangestriclamp hygienic(others on request) 1/2" BSPP or NPT(Lap Joint flanges on request) 1/2" BSPP or NPT(others on request) Environmental Protection IP66 (Nema 4), optionally flameproof to Exd IIB T4 (Class 1, Groups C & D) Recommended Filtering 150 microns (100 mesh)

  24. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Specifications - 25mm Model Prefix MP025S MP025A MP025H Body Material 316L stainless steel Aluminium 316L stainless steel Nominal Flow Range* 120 to 3000 lph (0.5 to 13.2 USGPM)*Turndown (flow range) varies in accordance with effective viscosity of metered liquid Accuracy +0.5% of rate Accuracy and turndown can be improved utilisingthe linearisation feature of the optional Trimec RT flow rate totaliser Repeatability Typically +0.03% under steady flow conditions Maximum Pressure 100 Bar (1500 psi) 80 Bar (1200 psi) 350 Bar (5150 psi) Temperature Range Three ranges covering operation from -40 to 150o C (-40to 300o F)limited to 80oC (176oF) with integral electronic register Piston Material Carbon filled teflon – option PEEKfor special materials - consult factory

  25. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Specifications - 25mm Model Prefix MP025S MP025A MP025H O-ring Material viton, EPR (EPDM), teflon encapsulated viton or nitrile (Buna-N) Reed Switch Output 30vdc maximum voltage, 20mA maximum current Pulse resolution: nominally 20 pulses / litre (76 pulses / US gallon) Open Collector Output 5 to 24vdc (25vdc maximum) 3 wire NPN (sinking current)20mA maximum current - 1000 metres (3300 ft) maximum transmissionPulse resolution: nominally 100 pulses / litre (380 pulses / US gallon) Electrical Connection M20 x 1.5 or 1/2" NPT female entries Process Connections 1" BSPP or NPT 1" ANSI 150/300RFflangesDN25 PN16 - 40 flanges triclamp hygienic(others on request) 1" BSPP or NPT(Lap Joint flanges on request) 1" BSPP or NPT(others on request) Environmental Protection IP66 (Nema 4), optionally flameproof to Exd IIB T4 (Class 1, Groups C & D) Recommended Filtering 250 microns (50 mesh)

  26. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Specifications - 40mm Model Prefix MP040S MP040A MP040H Body Material 316L stainless steel Aluminium 316L stainless steel Nominal Flow Range* 250 to 8000 lph (1.1 to 35 USGPM)*Turndown (flow range) varies in accordance with effective viscosity of metered liquid Accuracy +0.5% of rate Accuracy and turndown can be improved utilisingthe linearisation feature of the optional Trimec RT flow rate totaliser Repeatability Typically +0.03% under steady flow conditions Maximum Pressure 100 Bar (1500 psi) 30 Bar (440 psi) 350 Bar (5150 psi) Temperature Range Three ranges covering operation from -40 to 150o C (-40to 300o F)limited to 80oC (176oF) with integral electronic register Piston Material Carbon filled teflon – option PEEKFor special materials - consult factory

  27. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Specifications - 40mm Model Prefix MP040S MP040A MP040H O-ring Material viton, EPR (EPDM), teflon encapsulated viton or nitrile (Buna-N) Reed Switch Output 30vdc maximum voltage, 20mA maximum current Pulse resolution: nominally 7.3 pulses / litre (28 pulses / US gallon) Open Collector Output 5 to 24vdc (25vdc maximum) 3 wire NPN (sinking current)20mA maximum current - 1000 metres (3300 ft) maximum transmissionPulse resolution: nominally 44 pulses / litre (167 pulses / US gallon) Electrical Connection M20 x 1.5 or 1/2" NPT female entries Process Connections 11/2" BSPP or NPT 11/2" ANSI 150/300RFflangesDN40 PN16 - 40 flangestriclamp hygienic(others on request) 11/2" BSPP or NPT(Lap Joint flanges on request) 11/2" BSPP or NPT(others on request) Environmental Protection IP66 (Nema 4), optionally flameproof to Exd IIB T4 (Class 1, Groups C & D) Recommended Filtering 250 microns (50 mesh)

  28. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Specifications - 50mm Model Prefix MP050S MP050A MP050H Body Material 316L stainless steel Aluminium 316L stainless steel Nominal Flow Range* 700 to 20,000 lph (3 to 88 USGPM)*Turndown (flow range) varies in accordance with effective viscosity of metered liquid Accuracy +0.5% of rate Accuracy and turndown can be improved utilising the linearisation feature of the Trimec RT flow rate totaliser Repeatability Typically +0.03% under steady flow conditions Maximum Pressure 38 Bar (560 psi) 20 Bar (300 psi) 100 Bar (1500 psi) Temperature Range Three ranges covering operations from -40 to 150o C (-40to 300o F)limited to 80oC (176oF) with integral electronic register Piston Material carbon filled teflon – option PEEKFor special materials - consult factory

  29. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Specifications - 50mm Model Prefix MP050S MP050A MP050H O-ring Material viton, EPR (EPDM), teflon encapsulated viton or nitrile (Buna-N) Reed Switch Output 30vdc maximum voltage, 20mA maximum current Pulse resolution: nominally 2.5 pulses / litre (9.5 pulses / US gallon) Open Collector Output 5 to 24vdc (25vdc maximum) 3 wire NPN (sinking current)20mA maximum current - 1000 metres (3300 ft) maximum transmissionPulse resolution: nominally 20 pulses / litre (76 pulses / US gallon) Electrical Connection M20 x 1.5 or 1/2" NPT female entries Process Connections 2" BSPP or NPT2" ANSI 150/300RFflangesDN50 PN16 - 40 flanges triclamp hygienic(others on request) 2" BSPP or NPT(Lap Joint flanges on request) 2" BSPP or NPT(others on request) Environmental Protection IP66 (Nema 4), optionally flameproof to Exd IIB T4 (Class 1, Groups C & D) Recommended Filtering 500 microns (25 mesh)

  30. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Key Selling Highlights • The product concept has advantages over conventional positive displacement flow meters. • Up to 70% cost saving for an installation requiring a stainless steel flow meter. • Has only one moving part giving extended trouble-free working life. • Installation flexibility in vertical or horizontal pipes, no need for straight pipes runs or conditioned flow. • Has no stagnate chambers to accumulate contaminants or stale product.

  31. MP Key Selling Highlights • No modifications are needed when measuring high viscosity liquids. • Can be cleaned in place using chemicals or controlled steam pressure/temperature. • Quick and easy to clean in place without the need for special tools. • Extremely compact and comparatively light weight. • Limited number of spare parts needed to support the product.

  32. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Key Market Sales Areas • Key Market Sales Areas • The features of the Multipulse have broad appeal in all areas of industry and provide low cost of ownership and maintenance. • Chemical manufacturers or handling - acids or solvents. • Pharmaceutical's - medical and cosmetic liquids. • Pet food manufacturers, stock feed and poultry plants injecting food supplements and colourings. • Container filling machines and bottling equipment manufacturers. • Industries requiring 'in-line cleaning' confectionery, food and drink manufacturing. • Petroleum refineries, petroleum distribution, fuel additive injection systems, lube oil and grease dispensing. • Hydraulics and hydraulic driven epoxy injection systems. • Foam rubber manufacturers for injecting chemicals. • Paper manufacturing and related printing ink applications.

  33. Applications MP Adhesives Emulsions Insecticides Paints Inks Oils Fuels Grease Solvents Lubricants Chemicals Additives Resins Acids Alcohols Essences Edible Oils Flavourings Food Bases Perfumes

  34. Multipulse PositiveDisplacement Flowmeters Application MP Multi Head Filling Machine

  35. Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters Multipulse PositiveDisplacement Flowmeters MP Summary Trimec has achieved universal acceptance of its MP Series Positive Displacement Flowmeters, in a diversity of industrial flow measurement applications, as a result of innovative design concepts featured in its range of flow products. The meter capability has gained acceptance in the International Markets of the World, with established sales in Europe, Asia and now with entry into the United States market, Trimec is assured of being recognized as a leading manufacturer of quality flow measurement products.

More Related