An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Automatic Balancing Register Product Introduction Automatic Airflow Balancing ABR-4X4 ABR-6X4 ABR-6X6 ABR-8X8 ABR-10X10 (custom sizes available)

  2. Airflow Controlled by Physics, not electricity Contributing Inventors Aristotle Sir Isaac Newton Daniel Bernoulli Giovanni Venturi Concepts of continuum, flow and pressure Theory of air resistance and laws of motion Formula for calculating aerodynamic lift Relationship between pressure and flow

  3. HVAC “V” Ventilation accounts for 40 percent of the energy consumption in most buildings Every cubic foot of air taken out of a building has to be replaced by fresh outside air that has to be heated/cooled/dehumidified Ventilation costs approx. $10/CFM/YEAR Typical Example (very common): A hotel with 300 rooms averaging 70 CFM each when code only requires 35 CFM is wasting $105,000/yr. (cost to hotel for 300 ABR-6X6 units $12,600, ROI 43 days)

  4. Traditional Balancing vs. Auto-Balancing

  5. Stack Effect As heat rises in buildings during winter months the ventilation rates can more than double from “Stack Effect” The excess air forces the fans to freewheel Stale air from lower floors contaminates upper floors Result: Bad Air Quality & Wasted Energy

  6. Set It & Forget It! ABV Auto Balance Valves Each unit comes with a side label that enables field selection of desired airflow from 11 positions

  7. The Future of Airflow Balancing ABR Auto Balance Registers AdaptabilityPatented quick connect adapter ring for easy use with field plates and boxes Anti-microbial agent to prevent mold and bacteria Sealed TightOur grilles have a patented rubber gasket to get an airtight connection to walls 100% Proudly made in the USA Heavy Metal Fully enclosed in galvanized steel with aluminum grille Total Control11 Set-points that can be viewed and easily adjusted through the grille Bi-DirectionalEvery valve goes both ways (supply and exhaust)

  8. Automatic Balancing Registers ABR Auto Balance Registers All ABR units are fully enclosed in metal All units come complete with metal grille All units function as exhaust or supply All units have 11 airflow set-points All units proudly

  9. How To Get Precise and Automatic Airflow • Remove Existing Grille (2 screws) • Choose desired airflow using the set-point adjustment arm • Install the ABR Auto Balance Register (2 screws) Done!

  10. Advanced Materials ABV Auto Balance Valves Every unit contains our anti-microbial agent that prevents organic growth Prevents mold, algae, and bacteria for better air quality Valves stay cleaner without organic growth that grabs onto dust and dirt Less maintenance & better performance

  11. Automatic Balancing vs Traditional Test & Balance