For Dosimetry: Re-analyze Apollo dosimetry data using modern techniques

Recommendations from GROUP E (Dosimetry). For Dosimetry: Re-analyze Apollo dosimetry data using modern techniques (nuclear emulsions and PNTDs). Provide re-evaluated dose and dose equivalent, and neutron spectra measurements for Apollo missions.

jlevitt
Download Presentation

For Dosimetry: Re-analyze Apollo dosimetry data using modern techniques

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recommendations from GROUP E (Dosimetry) • For Dosimetry: • Re-analyze Apollo dosimetry data using modern techniques • (nuclear emulsions and PNTDs). Provide re-evaluated dose and • dose equivalent, and neutron spectra measurements for Apollo missions. • (2) Dosimetric measurements on Lunar (Martian) surface using Tissue • Equivalent Detectors that include both charged particle and neutron • contributions to dose and dose equivalent.

  2. Recommendations from GROUP E (Dosimetry) For SPE predictions (predictive tools for operational decisions) (3) Prediction of the next most likely SPE temporal evolution profile TH (at the selected energies), with associated probabilities. Real-time data from the actual event EXP (at the selected energies). Refine predictions in real time as the real-time data arrives. Quiet-time (all clear) forecast.

  3. Recommendations from GROUP E (Dosimetry) • Differential flux Prediction: • We need particles/time/cm2/MeV, at various times () before the event • i.e. (E, t, ) • (a) at 1 A.U. in free space, • at Mars and along the Mars trajectory • Protons (H) • Parameter Ranges we would like: • E: 30, 60, 100, 500, 1000 MeV • t: 5 mins, from t = 0 (onset) to return to background • : 0 (now), 3 hrs lead time, 6, 12 , 24 hrs. • Helium (He): • Parameter ranges same as above (except MeV/n, and cut off at 500MeV/n) • Electrons (e): • Parameters as above, except: • E: 0.5 – 5.0 MeV

  4. Recommendations from GROUP E (Dosimetry) FOR GCR and SPE (4) Determine the limits of the long-term variability in the space radiation environment including GCR, SPE, and Earth’s trapped radiation belts through continued research, e.g. the long-term secular changes in the GCR spectrum using 10Be from ice cores, Voyager measurements beyond the termination shock, nitrate measurements from ice cores, and historical data, with a view to prediction. (5) Endorse the support of missions that allow US access to the necessary data to enable the above. Monitoring at L1 is preferred because it is outside the magnetosphere, is at approximately 1 AU, and permits continuous coverage

  5. Recommendations from GROUP E (Dosimetry) For all of the above: (6) We also need a “Technology Transfer” mechanism - i.e. how to transfer research into operational tools.