二、共发射极单管放大电路

二、共发射极单管放大电路. 一、实验目的: 1 、熟悉本实验所用的仪器设备的使用方法及实验电路的原理和接线。 2 、学会放大电路静态工作点的调试方法,了解并分析静态工作点对放大电路性能的影响。 3 、掌握放大器电压放大倍数的测试方法。 4 、巩固和加深单管放大电路的基本知识。. 二、实验设备和器材 1 、电子学综合实验装置 DZX-3 型 一台 2 、双踪示波器 CA9020 型( COS620 型) 一台 3 、万用表 一台 4 、单管 / 负反馈两级放大器实验板 一块

ksena
Download Presentation

二、共发射极单管放大电路

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 二、共发射极单管放大电路 一、实验目的: 1、熟悉本实验所用的仪器设备的使用方法及实验电路的原理和接线。 2、学会放大电路静态工作点的调试方法,了解并分析静态工作点对放大电路性能的影响。 3、掌握放大器电压放大倍数的测试方法。 4、巩固和加深单管放大电路的基本知识。

  2. 二、实验设备和器材 1、电子学综合实验装置DZX-3型 一台 2、双踪示波器CA9020型(COS620型) 一台 3、万用表 一台 4、单管/负反馈两级放大器实验板 一块 5、连接导线 若干

  3. 三、实验电路图:

  4. 四、实验内容、步骤及方法 1、静态工作点的调试与测量 1)先将Rp调到最大; 2)选0~18V稳压源任意一组,使用数字直流电压表测试 (用20V档位),将其调至12V;

  5. 3)在放大器集电极直接串入直流数字毫安表。3)在放大器集电极直接串入直流数字毫安表。

  6. 4)将调好的12V电压正极接Ucc,负极接地,调整Rp,使Ic=2mA。4)将调好的12V电压正极接Ucc,负极接地,调整Rp,使Ic=2mA。

  7. 5)用数字电压表分别测UB、UE、UC的值; 断开开关K1后,用万用表10K欧姆挡测RB2值,并计算UCE、UBE、IC值。

  8. 6)所测值填入下表:

  9. 2、电压放大倍数的测量 1)保持原静态工作点,将数字直流毫安表换为导线;

  10. 2)开启频率计,测量调到内测,开启函数信号发生器,2)开启频率计,测量调到内测,开启函数信号发生器, 将输出信号调为1000Hz,10mV(使用40dB衰减); 3)将1000Hz,10mV信号接入放大器ui处;

  11. 4)用示波器观察Uo波形,在不失真的情况下,用交流数字毫伏表测量4)用示波器观察Uo波形,在不失真的情况下,用交流数字毫伏表测量 下述两种情况下的Uo值,并用双踪示波器观察Ui与Uo的相位关系, 记入下表;

  12. 四、实验结束注意事项 • 1、把直流电源调零(调到最小值); • 2、把示波器耦合调到GND; • 3、关闭实验台所有电源,把线放整齐,摆放好座椅; • 4、值日生留下做卫生。