An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Design Considerations for High Strength Wastewater John R. Blount, P.E. Harris County Public Infrastructure Department Assistant County Engineer Director, Architecture & Engineering Division

  2. Topics • Define high strength wastewater • Discuss hydraulic vs. organic loading • Explore results of Harris County high strength wastewater studies • Review relevant sections of 30 TAC §285 • Develop strategies for moving forward

  3. What is high strength wastewater? • Wastewater that has higher amounts of BOD, TSS, or FOG than residential wastewater Residential wastewater Strength < 300 mg/L BOD* High strength wastewater Photos: http://www.clker.com/clipart-scales-of-justice-3.html, http://www.aediconstruction.com/sustainability/low_flow_water_fixtures.html, http://www.bls.gov/ooh/Production/Food-processing-occupations.htm * Per 30 TAC §285.32(f)2

  4. What is high strength wastewater? • It is often highly variable • For example, a restaurant with a lunch rush http://www.southpaceblog.com/2012/11/06/what-to-expect-in-todays-restaurant-market/

  5. Why should I be concerned? • Conventional systems will not work well with high strength wastewater due to clogging of the soil interface. • High strength wastewater can cause faster decline of onsite systems without adaptations. Photo: http://bbprof.wordpress.com/2012/03/22/a-d-in-rhetoric/

  6. Quantity vs. Quality • Hydraulic loading • Water volume • Organic loading • Water quality • Know what you’re dealing with- do your detective work! Photo: http://www.glogster.com/1jbfan/detective-work/g-6n94f14apu919am1ppmuhdh

  7. How strong is strong? Total Daily Load Wastewater Flow Rates (gal per hour) + Wastewater quality Overall wastewater strength Agnoli, T. 2000. The best wastewater systems consider flow rate and waste strength. Small Flows Quarterly, 1 (2).

  8. Texas Restaurant Wastewater Analysis, 2003 • Pretreatment is necessary to prevent system failure • Highlighted the need for a design manual for restaurants Study funded by the Texas Onsite Wastewater Research Council

  9. Not all restaurants are created equal

  10. Texas Restaurant Wastewater Analysis, 2003 Values shown are averages

  11. Texas Restaurant Wastewater Analysis, 2003

  12. Harris County Low Flow Fixture Study, 2013 • Initiated November 2013 • Compare BOD, TSS, and FOG from an older residential neighborhood to a new neighborhood with low flow fixtures (and therefore, high strength wastewater) http://stockfresh.com/image/1722713/pending-rubber-stamp

  13. What about NSF 40? • Example: • Fast food restaurant with 33 seats, loading factor of 15 gpd/seat • According to TAC, 15 x 33 = 495. It might be assumed a 500 gpd treatment plant would suffice. However…

  14. What about NSF 40? • NSF Standard 40 treatment plants assume BOD= 240 mg/L • Harris County restaurant study average BOD = 1202 mg/L: 5 times greater! • Reality is this scenario would require a 2,500 gpd plant if you look at it on an organic loading basis.

  15. What does the TAC say? • “(1) Tank sizing. Proprietary treatment systems that serve single family residences, combined flows from single family residences, or multi-unit residential developments shall be designed using Table II in §285.91(2) of this title unless there is an equalization tank preceding the aerobic treatment unit. If there is an equalization tank preceding the aerobic treatment unit, the equalization tank shall meet the requirements set forth in §285.34(b)(4) of this title (relating to Other Requirements) and the aerobic treatment units can be sized using the wastewater flows in Table III in §285.91(3) of this title.” 30 TAC §285.32(c)

  16. Table III- Wastewater Usage Rate • Table III ONLY applies to hydraulic loading • “This table shall be used for estimating the hydraulic loading rates only. Sizing formulas are based on residential strength BOD5. Commercial/institutional facilities must pretreat their wastewater to 140 BOD5 prior to disposal unless secondary treatment quality is required. For design purposes, restaurant wastewater will be assumed to have a BOD5 of at least 1,200 mg/l after exiting the grease trap or grease interceptor.” 30 TAC §285.91(3)

  17. What does the TAC say? • “Proprietary units under this section have been approved to treat flows equal to or less than their rated capacity and with an influent wastewater strength ranging from a 30 day average Carbonaceous Biological Oxygen Demand (CBOD) concentration between 100 milligrams per liter (mg/l) and 300 (mg/l) and a 30 day average TSS concentration between 100 mg/l and 350 mg/l.” 30 TAC §285.32(c)5(A)i

  18. What does the TAC say? • “Restaurant/food establishment sewage. When designing for restaurants, food service establishments or similar activities, the minimum design strength value shall be 1,200 mg/L Biochemical Oxygen Demand (BOD) after a properly sized grease trap/interceptor. It is the responsibility of the designer to properly design a system which reduces the wastewater strength to 140 mg/L BOD prior to disposal unless secondary treatment levels are required.” 30 TAC §285.32(f)

  19. What does the TAC say? • Defines residential sewage as sewage that has a strength of <300 mg/L BOD • Designer should consider if flow equalization is necessary for system to work properly 30 TAC §285.32(f)2, 3

  20. Harris County Onsite Sewage Facility Regulations • “Calculations for hydraulic and organic load for both normal and peak flows on all commercial systems shall be provided showing that both organic and hydraulic overloading of the treatment and/or disposal method is prevented.” • Commercial maintenance frequency- 12 visits a year

  21. Conclusion • Systems that are improperly designed for the waste stream may not protect public health and the environment Photo: http://science.kqed.org/quest/2012/04/27/celebrating-earth-day-in-the-age-of-man/hands-on-a-globe/

  22. Ways to manage high strength wastewater 1. Control at the source • Example: scrape plates to reduce FOG 2. Treat to a higher level before discharge • Example: install media filter 3. Adjust loading rates according to strength of wastewater Source: Hammerlund and Glotfelty, Maryland Department of the Environment. 2008. Onsite Sewage Disposal of High Strength Wastewater. 17th Annual Maryland Groundwater Symposium 2008.

  23. Questions and/or Comments