1 / 1

μ track

d. L-d m. (x,y,z). θ c. d γ. Comparators’ output. Track Parameters θ : zenith angle φ: azimuth angle (Vx,Vy,Vz): pseudo-vertex coordinates. d m. t 1. t 2. t 3. t 4. t 5. t 6. HPTDC output.

les
Download Presentation

μ track

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. d L-dm (x,y,z) θc dγ Comparators’ output Track Parameters θ : zenith angle φ: azimuth angle (Vx,Vy,Vz): pseudo-vertex coordinates dm t1 t2 t3 t4 t5 t6 HPTDC output (Vx,Vy,Vz) pseudo-vertex Synchronous Detection of Extensive Air Showers with a Deep Sea ν-Telescope and a Floating Scintillator Array G. Bourlis, A. Leisos, A.G.Tsirigotis, S.E.Tzamarias Physics Laboratory, School of Science and Technology, Hellenic Open University, Greece φ array Θ array 5m Shower Reconstruction Synchronous detection and Calibration Charge & Arrival Time Estimation Simple Estimation: An Improved Method φ telescope Each HELYCON autonomous array can be used to select EAS passing close to the center of the floating platform (i.e. by requiring at least 5 active counters and by setting a threshold value (i.e. 20 mips) for the total collected charge). Then a simple estimation of the muon track direction can be made. That is the straight line (simple estimation) connecting the position of the center of the platform with the weighted mean (weighted by the observed charge) of the active1 optical modules positions. In this method, the resolution in estimating the shower axis zenith angle is less than one degree. In first order approximation the particle front is a plane moving with the speed of light. Actually the particle front is curved with a thickness that depends on the distance from the shower axis. By Monte Carlo integration we have calculated the time distribution of the signals (full detector simulation) with respect to the distance from the showers axis. The typical zenith angle resolution of a HELYCON station (3 scintillator counters at a distance of about 20 m) is 4.5 degrees. A floating array of Extensive Air Shower (EAS) detectors can be used as a sea-top calibration infrastructure, on top of the KM3NeT neutrino telescope. Such an array can detect the copiously produced, low energy and small zenith angle, atmospheric showers and the collected data can be used for the reconstruction of the direction and of the impact parameter of the shower axis. A large percent (35%) of the cosmic showers in the energy range of 1014 – 5 1015 eV contain energetic muons able to penetrate the sea water and reach the ν-detector. These muons are detectable by the deep-sea telescope and the muon track parameters can be estimated with high accuracy. For the charge estimation, a Multi Time Over Threshold Technique is applied. The measured charge is parameterized as a polynomial function of the sum of the times over threshold. The typical resolution is better than 10% while the arrival time resolution was estimated to be 2ns. GPS 3 stations for 10 days (XN,YN) Top of the atmosphere Analogue signal ~20 m 19m Θ w d Scintillator array Sea level (Xw,Yw) μ track Thickness Shower axis • Online Monitor of a HELYCON Station 3500 m depth Curved Particle Front ν-Telescope Number of showers The calibration method is based on the comparison between the reconstructed shower axis and the reconstructed muon track parameters. For example, the difference between the reconstructed zenith angles should follow a normal distribution with mean value equal to zero. Any statistical significant deviation of this mean value from zero, indicates that the estimations of the neutrino telescope suffer from a systematic angular offset. Collected Charge (mip) Muon Track Reconstruction di Scintillator Array dt3 dt=0 • Combination of Χ2fit and Kalman Filter (novel application in this area) using the arrival time information of the hits. • Charge – Direction Likelihood using the charge (number of photons) of the hits. Radial Distance (m) dt1 Number of counters>5 dt2 Shower Axis θw-θshower Number of counters>1 The simple estimation of the muon direction is compared, on an event by event basis, to the fully reconstructed muon track by the neutrino telescope. The distribution of the difference between the simple estimation of the muon parameter and the corresponding parameter of the reconstructed muon track, consists of a central Gaussian structure which is used for the evaluation of the calibration accuracy. di: distance from the shower axis Radial Distance (m) ν-Telescope μ track Angular resolution (median degrees) 1 station for ~40 hours of operation Θ telescope μ=0.15±0.3 The Scintillator array μ=0.010±0.045 Data Acquisition The floating array consists of 16 HELYCON detectors, arranged on a two-dimensional grid (5mx5m cell size) covering an area of about 360m2. The HELYCON charged particle detector is a scintillation counter of 1m2 active area. It is made of plastic scintillator tiles wrapped in Tyvek reflective paper, while the light is collected by wave shifting fibers embedded inside the grooves of the scintillating tiles and it is detected by a fast photomultiplier tube Energy (log(E/GeV)) The HELYCON Readout electronics offers up to five analog inputs, each one for a scintillation detector. The input signals are compared to six predefined (remotely adjustable) thresholds and the corresponding times of the PMT waveform-threshold crossings are digitized with an accuracy of 100 ps by the HPTDC. Single Shower and Full Data Set Calibration Accuracy 19m Summary & Results Sea Top station The single shower calibration accuracy is about 6.7 degrees but the accuracy on the mean value (full data set calibration accuracy) scales down inversely with the square root of the recorded events. By accumulating events using 3 indepedent floating stations in a 10-day operation, the resolution of estimating a possible angular offset is 0.04 degrees (km3 ν-Telescope at 3500m depth) σc =6.70 We have studied a new strategy of using floating detector arrays in order to investigate for possible systematic errors in track reconstruction by an underwater neutrino telescope. Assuming that three floating arrays collect, independently of each other, data for a period of ten days, we found that a possible offset in zenith angle estimation can be evaluated with an accuracy of 0.01o, whilst a similar offset in the azimuth angle can be found with an accuracy of 0.07o. Furthermore the coordinates of the center of the neutrino telescope, can be estimated with an accuracy better than 1 m. In this study we did not take into account correlations of the above systematic errors. Photonis XP-1912 Standard, 10-stage, 19 mm (3/4") round tube θshower-θmuon The trigger is realized in the Field Programmable Gate Array (FPGA) of the Readout card which is also responsible for formatting the data and for communicating with the station (local) PC. The data are saved on the hard disk of the local computer and transmitted on request, via the Internet, to a central server 160 Scintillation Tiles Improved method Standard method SeaWiet SeaWiet 96 WLS fibers νOne νOne Single PMT read out WLS fibers: Bicron (BCF-91A) Light attenuation length: 330cm

More Related