1 / 9

PROGETTO DI IMPIANTO FOTOVOLTAICO PER UN IPOTETICO SUPERMERCATO SITO IN LOCALITA’ CAORSO

PROGETTO DI IMPIANTO FOTOVOLTAICO PER UN IPOTETICO SUPERMERCATO SITO IN LOCALITA’ CAORSO. ITIS – IPSIA PIACENZA Anno scolastico 2009-2010. STUDI E VALUTAZIONI PRELIMINARI.

lindsay
Download Presentation

PROGETTO DI IMPIANTO FOTOVOLTAICO PER UN IPOTETICO SUPERMERCATO SITO IN LOCALITA’ CAORSO

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PROGETTO DI IMPIANTO FOTOVOLTAICO PER UN IPOTETICO SUPERMERCATO SITO IN LOCALITA’ CAORSO ITIS – IPSIA PIACENZAAnno scolastico 2009-2010

  2. STUDI E VALUTAZIONI PRELIMINARI • In funzione degli spazi disponibili e dei consumi stimati si è dimensionata la taglia dell’impianto (potenza finale 40,32 kWp) • PARTENDO DAI DATI GEOGRAFICI DELLA LOCALITA’ E CON L’AIUTO DI PROGRAMMI DEDICATI SI E’ VALUTATA LA DISPONIBILITA’ DELLA FONTE SOLARE (IRRAGGIAMENTO DISPONIBILE SUL SITO)

  3. PARAMETRI GENERALI D’IMPIANTO • SCELTA DELL’INCLINAZIONE PER I PANNELLI (30°) • IPOTESI E VERIFICA PER LA STRUTTURA PORTANTE (telai in alluminio ancorati al tetto piano) • VERIFICA DELLE OMBRE DATE DAL POSIZIONAMENTO DEI PANNELLI E DAGLI OSTACOLI PRESENTI • SCELTA TAGLIA PANNELLI (MODULI POLICRISTALLINI DA 210 Wp) • SCELTA TAGLIA INVERTER

  4. LAYOUT DI IMPIANTO

  5. SCHEMA UNIFILARE DI IMPIANTO

  6. VERIFICHE ELETTRICHE • SI E’ PROVVEDUTO AL CALCOLO DEI PARAMETRI ELETTRICI CARATTERISTICI PER L’IMPIANTO VERIFICANDO L’ORGANIZZAZIONE DELLO STESSO (NUMERO DI PANNELLI PER STRINGA, CORRENTI DEI BOX DI CONNESSIONE, TENSIONI MINIME E MASSIME DI LAVORO) PER IL NORMALE ESERCIZIO E NELLE CONDIZIONI ESTREME DI FUNZIONAMENTO (PER LE TEMPERATURE MASSIME E MINIME PREVISTE)

  7. PREVISIONI PER PRODUZIONE • UN SIMULATORE SPECIALISTICO HA CONSENTITO DI VALUTARE LA PRODUZIONE ELETTRICA MEDIA ANNUALE ATTESA PER L’IMPIANTO PARI A 47.861,5 kWh

  8. DOCUMENTAZIONE FINALE DI PROGETTO • RELAZIONE TECNICA • LAYOUT DI IMPIANTO • SCHEMA ELETTRICO UNIFILARE • DISPONIBILE PER OGNI CONSULTAZIONE

  9. GRAZIE PER L’ATTENZIONE (E LA PAZIENZA)

More Related