1 / 15

Oleh Kelompok 3: Andriyansyah Arie Kurnia Budi Santoso Endah Kusuma Rani

ANALISIS SISTEM PROSES Dosen: Ir. Abdul Wahid, MT Ir. Tania Surya Utami, MT. IDEAL BINARY. Oleh Kelompok 3: Andriyansyah Arie Kurnia Budi Santoso Endah Kusuma Rani. Don’t Visite Us at http://www.asp-ideal_binary_distillation.chemeng.ui.ac.id. Sketsa Proses. I T H I N K 5.1.1.

liora
Download Presentation

Oleh Kelompok 3: Andriyansyah Arie Kurnia Budi Santoso Endah Kusuma Rani

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ANALISIS SISTEM PROSESDosen: Ir. Abdul Wahid, MT Ir. Tania Surya Utami, MT IDEAL BINARY Oleh Kelompok 3: Andriyansyah Arie Kurnia Budi Santoso Endah Kusuma Rani Don’t Visite Us athttp://www.asp-ideal_binary_distillation.chemeng.ui.ac.id

  2. Sketsa Proses

  3. I T H I N K 5.1.1 P E N A E N N A T L U I A S N A & S H O A L S U I S L I Kondisi Steady State Steady State dengan Variasi R Kondisi Dynamic Sensitivitas & Kesimpulan FROM IPTEK WITH LUV!!!!

  4. Perumusan Model • Overhead receiver • Rectifying section (dari i=2 sampai NF-1) • Feed

  5. Perumusan Model (cont’d) • Stripping section (i=NF+1 sampai NS-1) • Reboiler

  6. Permasalahan Kasus: Feed masuk ke kolom distilasi dengan kolom distillasi sebanyak 5 stage. Datanya: • α = 1.5 • F = 1 mol/min • ZF = 0.5 fraksi mol komponen ringan • R = 2.706 • D = 0.5 mol/min • QF = 1 (Saturated Liquid) • LS = 3.706 mol/min • VS = 3.206 mol/min • B = 0.5 mol/min • MD = 5 mol • MT = 0.5 mol • MB = 5 mol

  7. Steady State Kondisi steady state yang didapat dari Software IThink adalah • X1 = 0.67 • X2 = 0.57 • X3 = 0.49 • X4 = 0.41 • X5 = 0.33 IThink

  8. Kondisi Dinamik Setelah didapat nilai X1, X2, X3, X4 & X5 dari kondisi steady state maka nilai-nilai tersebut akan dipakai di kondisi dinamik. Kondisi dinamik: Akan dilihat pengaruh perubahan Refluks terhadap XD dan XB

  9. Variasi R Diperoleh hasil: • Pada distilat, semakin besar refluks maka XD mulai naik hingga stabil • Pada bottom, semakin besar refluks maka XB mulai turun hingga stabil IThink

  10. Kondisi Dinamik (cont’d) Pada kondisi dinamik, akan dilihat respon dari nilai XD dan XB terhadap perubahan step pada refluks sebesar +1% dan –1% dan menurut perubahan waktu. IThink

  11. Kondisi Dinamik (cont’d) Dapat dilihat: • Pada perubahan refluks sebesar +1% maka XD akan naik dan XB (seharusnya) akan naik • Pada perubahan refluks sebesar –1% maka XD akan turun dan XB (seharusnya) akan turun

  12. Sensitivitas Sensitivitas terhadap: • F (laju alir feed) • ZF (komposisi fasa cair di feed)

  13. Analisa Sensitivitas • Perubahan F dengan qF>0.5 menyebabkan sensitivitas stage di bawah tray feed lebih besar. • Sensitifitas terhadap perubahan zf di stage feed relatif lebih besar Sensitivitas terhadap F Sensitivitas F IThink Sensitivitas terhadap ZF Sensitivitas ZF

  14. Kesimpulan * Komposisi steady state pada kasus awal: x1=0,67; x2=0,57; x3=0,49; x4=0,41; x5= 0,33 • Gangguan step positif pada R menyebabkan x1 naik dan x5 turun, dan sebaliknya. • Sensitivitas terhadap perubahan 10%: - F di bagian stripping relatif lebih besar - zf di bagian feed tray relatif lebih besar

More Related