1 / 14

5 MeV Mott Measurement

5 MeV Mott Measurement. Overview: polarized electrons Mott scattering injector polarimeter training & qualification. for CEBAF Operations group Joe Grames, Marcy Stutzman February 14 th , 2007. Sir Nevill F. Mott at the ceremony with his Nobel Prize for Physics, 1977. ( N + - N - ).

maia
Download Presentation

5 MeV Mott Measurement

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 5 MeV Mott Measurement • Overview: • polarized electrons • Mott scattering • injector polarimeter • training & qualification for CEBAF Operations group Joe Grames, Marcy Stutzman February 14th, 2007 Sir Nevill F. Mott at the ceremony with his Nobel Prize for Physics, 1977

  2. (N+ - N-) Polarization = (N+ + N-) What is a polarized beam? A beam is polarized in a specific direction if the average value of all the spins along that direction is not zero. (9 - 1) = 80% (9 + 1)

  3. Polarized electron beam • Circularly polarized laser light on GaAs • Polarized electrons generated • Polarization is longitudinal • Parallel or anti-parallel to direction of beam motion (this is called the helicity) • Wien filter used to change direction of polarization • Polarization direction changes, but beam orbit unchanged (use injector steer script)

  4. (R1 – R2) = Aexp Analyzer • Pbeam= (R1 + R2) What is a polarimeter? A polarimeter is a tool which analyzes the polarized beam in a way that an observer (you) may physically detect and measure. R1 Beam R2

  5. Mott scattering • “Low” energy electrons (20 kV- 10 MeV) • Heavy nucleus atoms (e.g., gold Z=79) • “Spin-orbit” interaction • Interaction of orbital angular momentum of electron (L) and its magnetic moment (µs) • VSO~ L· µs • Sensitive to electron polarization direction transverse to beam motion

  6. Sherman function • Scattering asymmetry • Sherman function • Depends on electron energy, target material, scattering angle

  7. Polarimeter targets • Targets • Ideal target: single heavy nucleus, e.g., Au, Ag or Cu • Real target: thick foils (nm or mm), diluted Sherman function, extrapolation to zero thickness

  8. Target Corrector Detector Hut Dump Dipole Target/ Viewer Ladder Vacuum Valve Target Chamber Setup Viewer Start with beam to FC2. A script reliably steps you through Mott setup. Perform measurement of beam polarization. The script restores conditions when finished.

  9. (R1+ - R1-) AR1exp = (R1+ + R1-) Why flip the helicity? We reverse the sign (+ or -) of the beam polarization at ~30 Hz to cancel differences between the two detectors (R1 or R2). For each detector we measure an asymmetry: (R2+ - R2-) AR2exp = (R2+ + R2-) We combine asymmetries for the two detectors (AR1exp AR2exp) to arrive at a “super asymmetry” Aexp is proportional to the polarization. Aexp = S • Pbeam Analyzer (known) measured unknown

  10. Detector Spectra • Detector package • E (energy) • DE (discriminates photons) • Mott data analysis automated • Looks for asymmetry between up and down counts

  11. Detector Asymmetry electronic threshold inelastic elastic

  12. Mott operation • Spin must be rotated transverse to get a Mott asymmetry (Wien filter ~70° or more) • Target • We routinely use our 1 mm gold foil • Extrapolated Sherman function well known • Beam current 0.5 to 1 mA sufficient for 5 min run • Use FC1 to ensure <1uA • FC2 is downstream of the Mott dipole – won’t help during measurement • Backgrounds • Field emission from 0L03/0L04 cryomodules • “Auto-Joan” disabled so that we can turn off injector cryomodules

  13. Training • Qualification – means sitting w/ expert to watch & learn, then you do w/ expert present & finally “signed off”: • Preparing for Mott • Delivering beam to polarimeter • Changing the Wien angle • Beam setup troubleshooting • Adjusting detector HV • Making a measurement • Logging the data • Backing out of Mott

  14. Okay, Sir Nevill Mott says, “ let’s measure the beam polarization!”