高压电工实践

高压电工实践. XGN2-12 ( Z )箱型固定式金属封闭开关设备 的运行与试验. 基本要求 了解 XGN2 - 12 ( Z )箱型固定式金属封闭开关设备的结构、用途和操作;熟悉设备的原理及常见故障处理;掌握例行试验的内容和运行方法;了解工程中常用的标准和图集。. 基本内容 1 系统概论 2. 根据给定系统图、二次原理图和配线图,对照实物分析、描述系统的工作原理,操作、保护和元器件的动作过程。 3. 根据 GB3906 标准对系统进行例行试验 4. 以设备为现场,模拟现场的操作和故障排除。 5. 按工程要求编写相关工程材料:. 第一章 系统概论.

malory
Download Presentation

高压电工实践

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 高压电工实践 XGN2-12(Z)箱型固定式金属封闭开关设备 的运行与试验

  2. 基本要求了解XGN2-12(Z)箱型固定式金属封闭开关设备的结构、用途和操作;熟悉设备的原理及常见故障处理;掌握例行试验的内容和运行方法;了解工程中常用的标准和图集。基本要求了解XGN2-12(Z)箱型固定式金属封闭开关设备的结构、用途和操作;熟悉设备的原理及常见故障处理;掌握例行试验的内容和运行方法;了解工程中常用的标准和图集。 基本内容 1 系统概论 2.根据给定系统图、二次原理图和配线图,对照实物分析、描述系统的工作原理,操作、保护和元器件的动作过程。 3.根据GB3906标准对系统进行例行试验 4.以设备为现场,模拟现场的操作和故障排除。 5.按工程要求编写相关工程材料:

  3. 第一章 系统概论 §1.电力系统 §2.电力系统的形成和发展 §3.电力系统的特点和运行的基本要求 §4.电力网 §5.变电所类型 §6.电力系统基本结线方式 §7. 通用术语

  4. 区域电力系统图

  5. 电源 母线 断路器 负荷 线路 放射式结线

  6. 干线式结线 网格式结线

  7. 第二章 10KV高压成套开关设备 §1-1 户内式高压开关设备 KYN28-12 XGN66-12 XGN-12 KYN1-12 Z HXGN GG-1 A

  8. §1-2 一次方案 07号方案的一次系统组成:隔离开关、真空断路器、电流互感器、避雷器、带电显示器。 44号方案的一次系统组成:电流互感器、电压互感器、熔断器。 07号方案 44号方案

  9. §1-3 断路器 SN10 - 10 型高压少油断路器 ZN28A - 12 型高压真空断路器 CD19B型 弹簧操动机构 主触点 分、合闸线圈 辅助触点 真空断路器结构

  10. §1-3 隔离开关 打开状态 GN30 型户内交流高压旋转式隔离开关 闭合状态 JSXGN 型箱式柜用机械闭锁