An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. What is DEER? • Database for Energy Efficient Resources -A listing of residential and non-residential energy efficiency measures located at: http://eega.cpuc.ca.gov/deer/ • DEER provides measure and building specific: • Ex ante savings values: kW, kWh, kBtu; • Measure costs; and • Effective measure life (EUL)

  2. Non-Weather Sensitive Residential Measures Include: • CFL Lighting • Refrigerators • Clothes Washers & Dryers • Dishwashers • Water Heating • Swimming Pool Pumps

  3. Non-Weather Sensitive Res. MeasuresResidential CFL Savings CFL savings impact = (delta watts/unit * hours/day * days/year * In Service Rate) / 1000 watts/kWh CFL demand impact =delta watts/unit * In Service Rate * Peak Hour Load Share The “In Service Factor” is an estimate of the percentage of lamps that are actually used. “Hours of Operation/Day” and “Peak Hour Load Share” from KEMA CFL Metering Study. For example (14W CFL replace 60W Inc): CFL savings impact = 35.4 kWh (46W * 2.34 hours/day * 365 days/year * 0.9) / 1000 watts/kWhCFL demand impact =3.35 W46W * 0.9 * 0.081

  4. Non-Weather Sensitive Res. MeasuresResidential Water Heating Measures High efficiency water heater (electric EF=0.93, gas EF=0.63)Heat pump water heater (EF=2.9)Point of use water heaterLow flow showerhead (from 2.5 to 2.0 gallons per minute)Pipe wrapFaucet aerators Savings expressed as % of base useBase use varied by utility service area (same method as 2001)

  5. Non-Weather Sensitive Non-Res. Measure Groups • Interior Lighting • Exterior Lighting • Cooking • Copy Machine • Water Heating • Vending Machine Controls • High Efficiency Motors • Agriculture

  6. Non-Weather Sensitive Non-Res. Measures • Interior Lighting Group:CFL screw-in lamps CFL hardwire fixtures High intensity discharge (HID) lamps Premium T8 lamps Dimming Ballasts De-lamping fluorescent 4 ft and 8 ft fixtures

  7. Non-Weather Sensitive Non-Res. Measures • Exterior Lighting & Exit Signs MethodsHID lamps: delta watts saved * hours of use (4,100 hours) no peak impactsExit Signs: delta watts saved * 8760 hours * Interactive Effects peak = delta watts * Interactive effects * 1.0 (coincidence factor)Timeclocks & Photocells: watts controlled * hours of control no peak impacts

  8. Weather Sensitive MeasuresMethods Used • Employed DOE-2/eQUEST heat load simulation model • Hourly simulation of all elements • Includes details of configurations • Measures include high efficiency AC, furnaces, controls, shell measures, and maintenance (for single family, multi family, mobile homes and 22 non-res. building types, in each of 5 building vintages, for 16 climate zones).

  9. Weather Sensitive MeasuresCalibration • Residential • Residential Appliance Saturation Survey (RASS) used to calibrate end-use values • Non-residential • Adjustments both at “activity area” and whole building level using preliminary Commercial Energy Use Survey (CEUS) values and values from EM&V studies

  10. Weather Sensitive MeasuresSimulation cases • Base case • Vintage typical base on survey data • Code base Case • Minimally compliant or standard practice • Measure Case • Most common program tier's

  11. Overview of 2001-2005 Data Changes • The scope of some measures has been expanded • CFL size categories expanded • More evaporative cooler options • Windows expanded to include non-res. high performance glazing • Several measures eliminated or reduced in scope • Most T8 systems eliminated with the exception of premium efficiency and dimming T8 ballasts • Eliminated coin-operated high efficiency clothes washers and hot water heater tank wrap • Major changes in savings for some measures • Programmable thermostats • CFLs • Low flow showerheads • AC units

  12. Measure costs specifications encompass the sizes and technical specs of measures used in the energy analysis, but reflect availability of products on the market Cost data is first cost only -- life cycle or O&M costs/cost savings not included Some price observations (outliers) excluded; rational purchasing policy assumed (“who would pay THAT?”) Equipment and labor prices are specific to California to extent possible (average across state) Cost units ($ / ton, $ / HP, $ / square foot, etc.) Mostly the same although different for some measures Distinct field in detailed cost data; appended to Cost Basis designator in measure detail Defining Measure Cost Parameters

  13. How to find the most applicable cost information? Measure detail pages for each run ID - the per unit equipment measure cost of $13.65 for all 90% residential furnaces This provides an average cost based on a 100,000 Btu furnace The ‘Cost Data’ file under ‘Supporting Documents’ provides prices on a range of furnace sizes This provides a range of costs for 90% AFUE furnaces from 60,000 Btu to 140,000 Btu. Per unit costs ($/KBtu) ranges from $21.53 to $12.13, respectively The cost workbook section – Can use either statistical summary or individual price observations For example, the per unit equipment measure cost for 90% AFUE 100,000 furnaces ranges from to $12.31 to $16.52 based on 9 observations Cost Data Defining Cost Parameters

  14. Website Considerations • Two Levels of Savings • Customer savings - for system savings and early replacement savings. • “Above Code” Savings - for all measures affected by an energy code or standard (reportable savings for replace on burnout.) • Common Units • The energy and cost common units are distinct • Over 90% of cases, they are the same • When different, distinctly identified

  15. Website Considerations • Application – indicates if the cost is for: • Retrofit (RET) - replacing a working system with a new technology or adding a technology. • Replace-on-burnout (ROB) - replacing a technology at the end of its useful life • New construction or major renovation (NEW) - installing a technology in a new construction or major renovation • Cost Basis – indicates if the cost is: • Incremental (INCR) - the differential cost between a base technology and an energy efficient technology • Installed (FULL) - the full or installed cost of the measure including equipment, labor, overhead & profit (OH&P)

  16. Website Navigation – Opening Screen

  17. Website Navigation – Browse Measures

  18. Website Navigation – Select Subcategory

  19. Website Navigation – Review Summary Page - Top

  20. Website Navigation –Summary Page Information • Area #1 - Summary Identification of 13 variables • Area #2 – Further Filtering Options • Climate Zone, Building Type, Vintage, Savings Unit • Area #3 – Sorting Order • Area #4 – Download Measure Detail in Excel

  21. Website Navigation – Review Summary Page - Bottom

  22. Website Navigation – Detailed Measure Information

  23. Website Navigation – Detailed Measure information - Top

  24. Website Navigation – Detailed Measure information - Bottom

  25. Supporting Documents Section • Website Users Guide • Net-to-Gross Ratios Table (if in doubt use .8) • Access Tables • Glossary • Cost Data • Cost Data User’s Guide • New EUL Estimates (7-14-05 SERA Report) • Consolidated Measure Data