MP17 All Ss Electric Contact Pressure Gauge - High Version Case

"MIEPL make Electric Contact Gauge use wherever the process pressure has to be indicated locally and, at the same time, limit values must be monitored, contact pressure gauges and their application.<br><br>The switch contacts make or break the circuit dependent upon the pointer position of the indicating measuring instrument. If the reading is signiuf001cantly above or below a set value, they trigger an alarm, hence also the term u201calarm contactu201d. Contact pressure gauges are also suitable for starting, stopping or switching processes."<br>Get more information visit on:-http://www.miepl.com/<br>our mail I.D:-info@miepl.com, sales@miepl.com, mieplinstruments@gmail.com<br>Contact us at:- 91-11-22014325, 22014327<br>

Download Presentation

MP17 All Ss Electric Contact Pressure Gauge - High Version Case

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MP17 ALL SS ELECTRIC CONTACT PRESSUREGAUGE High VersionCase MIEPL make Electric Contact Gauge use wherever theprocesspressurehastobeindicatedlocallyand, at the same time, limit values must be monitored, contact pressure gauges nd their application. The switchcontactsmakeorbreakthecircuitdependent uponthepointerpositionoftheindicatingmeasuring instrument. If the reading is signicantly above or below a set value, they trigger an alarm, hence also the term “alarm contact”. Contact pressure gauges are also suitable for starting, stopping or switching processes. FEATURES All SS measuring system Socket-case, directwelded CE markedcontacts Liquid filledversions APPLICATION Pumps & motorcontrols Water treatmentplants Hydraulic &pneumatics Chemical &petrochemicals Pharmaceuticalindustries Compressors &utilities : AISI 304 SS (Bayonettype) Case & Ringmaterial : AISI 316L SS (Shank welded directly tocase) Bourdon tube &Shank : AISI 304SS Movementmechanism : Aluminum,blackgraduationonwhitebackground Dial Pointer : Fixed, aluminum, black powdercoated Gaskets, Blow off disc & fillingplug : Neoprene /NBR REFERENCE : Shatterproof safetyglass Window EN837-1 NOTE : Gauge accuracy shall be CL 1.0. but switching accuracy shall be CL5.0 MATERIAL OFCONSTRUCTION Window : Shatterproof safetyglass Dampeningliquid : Dielectricoil Gaskets, Blow off disc & fillingplug :Viton TEMPERATUREEFFECT Please refer clause no 9.3 of EN837-1 www.miepl.com ISO 9001 :2015

  2. MP17 ALL SS ELECTRIC CONTACT PRESSUREGAUGE DRAWING DIMENSIONALDRAWING B DIN 4Pin Connector. A ØC ØD E B S1 ØI ØU DIN 4Pin Connector. ØN A 120° M ØC ØD E K F 2" Pipe Mounting Bracket. B DIN 4Pin Connector. A ØD ØC J G 2"Pipe Size 2"U-Bolt and Nut. H E All dimensions are inmm. www.miepl.com ISO 9001 :2015

  3. MP17 ALL SS ELECTRIC CONTACT PRESSUREGAUGE DRAWING DIMENSIONALDRAWING B DIN 4Pin Connector. A ØC ØD DIMENSIONALDRAWING ØI ØU ØN B A DIN 4Pin Connector. 120° ØC ØD E DIMENSIONALDRAWING DIN 4Pin B Mounting Bracket "C"Type. Connector. A ØC ØD K J E V All dimensions are inmm. www.miepl.com ISO 9001 :2015

  4. MP17 ALL SS ELECTRIC CONTACT PRESSUREGAUGE MP17 - D - XXX - 1A - 4NM - IP2 - E1 - PRE-C - ECD1 -XX ORDERINGCODE D 100mm 1. DIALSIZE F 150mm XXX Refer “RangeTable” 2.RANGE 1A Direct Bottomconnection PATTERN PROTECTION 1B Wall/Surface/Projection mounting, Bottomconnection 1C 2" Pipe/Yoke mounting, Bottomconnection 3.MOUNTING PATTERN Lower, Backconnection 2E Panel/Front ange mounting, Lower Backconnection 2F Panel/bracket mounting, Lower Backconnection 2G 2BM ¼" BSP(M) 2NM ¼" NPT(M) 3BM 3/8" BSP(M) 4. PROCESS CONNECTION 4BM ½" BSP(M) 4MM M20 X 1.5 mm(M) 4NM ½" NPT(M) Otherthreadsizeandstandardsavailableonrequest.¹ 5. INGRESS PROCESS IP2 IP65 Dry E1 6.EXECUTION Dry but llable, dielectricoil³ E6 Dampening liquid, dielectricoil³ E7 PRE-C Precisioncontacts 7. SWITCH CATEGORY ATEX/CE Approvedcontact RT ECD1 Break contact(1NC) ECD2 Make contact(1NO) ECD3 2 x Break contact(2NC) 8. ELECTRIC CONTACT2 ECD4 2 x Make contact(2NO) ECD5 1 Break + 1 Make(1NC+1NO) ECD6 1 Make + 1 Break(1NO+1NC) 9. OTHER OPTIONS OrderingExample: MP17- - - - - - - For other connections, please contact factory. Economic contacts & Precision contact are available in Electric contact types ECS1…ECS6 & ECD1…ECD6respectively. Rubber parts shall be inViton. www.miepl.com 04 ISO 9001 :2015 MILLENNIUM INSTRUMENTSLIMITED Tel : +91- 11- 220 143 25 / 27, Email :mil@miepl.com