An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2011 Data Gap Investigation DNAPL Investigation in FWDA Outside the Barrier Wall Oregon DEQ, Hart Crowser, Inc., and GSI Water Solutions

  2. Wells with NAPL Outside Barrier Wall MW-Ds MW-Gs MW-20i MW-10s Inside Barrier Wall EW-1s EW-18s EW-8s MW-22i EW-23s MW-10r EW-15s MW-56s NAPL Thicknesses posted are from June 15, 2010

  3. 2011 DNAPL Investigation • Purpose – To assess the nature, extent, source(s), and potential pathway(s) of DNAPL to MW-20i • Conclusion – The source of DNAPL to MW-20i is small and localized. No evidence of a threat to the Willamette River. • DEQ and EPA Recommendation – Terminate NAPL recovery in late April 2011, and conduct four subsequent gauging efforts to assess whether NAPL thicknesses increase

  4. 2011 NAPL Investigation Objectives • Determine whether there is potentially mobile DNAPL within the backfill of two City of Portland (COP) high pressure sewer lines in the vicinity of MW-20i; • Determine whether there is a pool of mobile DNAPL overlying the silt that migrates to MW-20i (or elsewhere); and • Investigate the relationship between the DNAPL observed in monitoring wells MW-20i, MW-Gs, and MW-Ds.

  5. DNAPL Investigation Area

  6. DNAPL Investigation Locations

  7. 2011 NAPL Investigation Results • Pot holing did not reveal NAPL within the backfill surrounding the high pressure sewer lines near MW-20i. • While limited sheen and staining were observed, exploratory drilling did not reveal a pool of mobile DNAPL in the vicinity of MW-20i. There is no evidence of a source of mobile NAPL with a continuous pathway to the River.

  8. Fence Diagram showing conceptual NAPL extent before the investigation

  9. Fence Diagram showing refined conceptual NAPL extent

  10. Fence Diagram showing refined conceptual NAPL extent

  11. MW-Ds (outside, FWDA)

  12. NAPL Monitoring:MW-Ds (outside, FWDA)

  13. NAPL Monitoring:MW-Gs (outside, FWDA)

  14. NAPL Monitoring:MW-Gs (outside, FWDA)

  15. NAPL Monitoring:MW-20i (outside, FWDA)

  16. NAPL Monitoring:MW-20i (outside, FWDA)

  17. NAPL Monitoring: EW-1s (inside, TFA)

  18. NAPL Monitoring: EW-1s (inside, TFA)

  19. DNAPL Investigation Conclusions • Thin layers of sheen and staining were observed primarily within the smear zone, overlying finer-grained units and few stringers within the sand with depth • No evidence of mobile NAPL in borings • Source of NAPL to MW-20i was not identified; however, given the numerous investigation boring conducted in the vicinity in 2004-2006, there is clearly no significant pool of NAPL that could threaten the Willamette River There is no compelling evidence of NAPL migration to the Willamette River, and therefore, no reason to continue to recover NAPL from wells outside the barrier wall