RAPID TEST, DESIGNED FOR THE DETECTION OF MALARIA ( 4 plasmodium)

RAPID TEST, DESIGNED FOR THE DETECTION OF MALARIA ( 4 plasmodium). Toda Malariadiag 4+®. PROVIDED MATERIAL. 10 Cassettes individually packed in aluminium pouch containing dessicant bag 1 dropper vial containing the lysis buffer Notice d’utilisation 1 instruction for use.

neviah
Download Presentation

RAPID TEST, DESIGNED FOR THE DETECTION OF MALARIA ( 4 plasmodium)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RAPID TEST, DESIGNED FOR THE DETECTION OF MALARIA( 4 plasmodium) Toda Malariadiag 4+®

  2. PROVIDED MATERIAL • 10 Cassettes individually packed in aluminium pouch containing dessicant bag • 1 dropper vial containing the lysis bufferNotice d’utilisation • 1 instruction for use

  3. Avantages du Toda Malariadiag4+® • Use: simple, direct levy on the test • Fast: Result in 20 minutes • Ambient temperature storage • Reliability: • Specificity : P. falsiparum: 100,0% • Sensitivity P. falsiparum: 95,9% • Long expiration life: until 18 months

  4. Test Procedure Fig.1: Clean the sampling area (side of the third or the fourth finger) with an antiseptic solution.

  5. Test Procedure Fig.2: Remove the protective cover by turning and twisting in one movement.

  6. Test Procedure Fig.3: Position it against puncture site. Hold it between fingers and press colored button firmly with thumb to activate. Do not pull away from site until after activation. Collect specimen.

  7. Test Procedure Fig.4: Massage the finger in order to make come out a drop of blood. Put the edge of the strip in contact with the drop of blood. The drop should be placed in the center of the open zone on the absorbent pad.

  8. Test Procedure Fig.5 : Place the cassette on a flat surface and then add four drops of lysis bu er in the well. Read the result after 20 minutes from the time the buffer is dropped.

  9. Wait 20 minutes

  10. Positive résult POSITIVE: 3 purple stripes appears POSITIVE FOR OTHER SPECIES : 2 purple stripes appears

  11. Négative and not significant résults NEGATIVE : Only one stripe appears in the area C. NOT SIGNIFICANT : Absence of purple stripe in the control area C. The procedure was not correctly followed or the test was damaged. run the procedure again with a new device.

  12. Santé-Voyage 83 avenue d’Italie 75013 PARIS Tél 01 45 86 41 91 Mail: info@astrium.com