1 / 69

Safety Chapter 9 includes: Electrical safety RF Exposure Antenna Safety

Safety Chapter 9 includes: Electrical safety RF Exposure Antenna Safety. Electrical Safety Section 9.1. Most modern radio equipment is solid state and uses low voltage dc power, but the ac line voltage that powers most equipment is dangerous.

sofia
Download Presentation

Safety Chapter 9 includes: Electrical safety RF Exposure Antenna Safety

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Safety Chapter 9 includes: Electrical safety RF Exposure Antenna Safety

  2. Electrical Safety Section 9.1

  3. Most modern radio equipment is solid state and uses low voltage dc power, but the ac line voltage that powers most equipment is dangerous.

  4. Electrical hazards can result in two types of injury: shocks and burns These occur when current flows through the body.

  5. The burns are caused by the heating of tissue as current passes though the body. Electrical current can also disrupt the normal electrical function of cells The current can cause involuntary muscle contractions (T0A02)

  6. It only takes 30 volts to cause enough current flow to be dangerous. (T0A01) 120 volts

  7. The best way to avoid electrical shock is the never work on “live” equipment; UNPLUG it first!

  8. Remember: capacitors store electrical charge in a circuit, even after the electricity is turned off. This can present a hazardous shock voltage for a long time. (T0A12) Make sure all capacitors are discharged before working on equipment.

  9. The National Electrical Code and local building codes ensure that the wiring and outlets in your home are safe, and that a safety ground is properly installed. You can operate your radio in complete safety when powered from your home’s ac wiring; as long as you follow these simple guidelines: (T0A06)

  10. Use 3 wire power cord • Connect all equipment to a common ground • Use ground fault circuit Interrupter (GFCI) circuit breakers. • Never replace a fuse or circuit breaker with a larger size • Don’t overload single outlets.

  11. If you need new wiring (hire a licensed electrician) and inspect it to make sure it follows the wiring standard as shown: Hot = black neutral = white green/bare = ground (T0A03)

  12. If you build your own equipment; always install a fuse or circuit breaker in series with the ac hot conductor (T0A13)

  13. It is wise to take precautions with your radio equipment to protect it from lightning damage. Lightning protection is intended to provide fire protection for your home.

  14. All antenna towers, masts and antenna mounts should be grounded according to your local building codes. (T0B11) This is done at the base or in if it is a roof mount , through a large-diameter wire to a ground rod.

  15. Ground connections should be as short and direct as possible. (T0A11) It is important to avoid sharp bends in the connecting wire. (T0B10)

  16. When cables and feed lines enter the house, ground all devices to a common plate that is connected to a nearby external ground. (T0A07)

  17. T0A01 Which is a commonly accepted value for the lowest voltage that can cause a dangerous electric shock? A. 12 volts B. 30 volts C. 120 volts D. 300 volts

  18. T0A02 How does current flowing through the body cause a health hazard? A. By heating tissue B. It disrupts the electrical functions of cells C. It causes involuntary muscle contractions D. All of these choices are correct

  19. T0A03 What is connected to the green wire in a three-wire electrical AC plug? A. Neutral B. Hot C. Safety ground D. The white wire

  20. T0A06 What is a good way to guard against electrical shock at your station? A. Use three-wire cords and plugs for all AC powered equipment B. Connect all AC powered station equipment to a common safety ground C. Use a circuit protected by a ground-fault interrupter D. All of these choices are correct

  21. T0A07 Which of these precautions should be taken when installing devices for lightning protection in a coaxial cable feedline? A. Include a parallel bypass switch for each protector B. Include a series switch in the ground line of each protector to prevent RF overload C. Keep the ground wires from each protector separate and connected to station ground D. Ground all of the protectors to a common plate which is in turn connected to an external ground

  22. T0A11 Which of the following is good practice when installing ground wires on a tower for lightning protection? A. Put a loop in the ground connection to prevent water damage to the ground system B. Make sure that all bends in the ground wires are clean, right angle bends C. Ensure that connections are short and direct D. All of these choices are correct

  23. T0A12 What kind of hazard might exist in a power supply when it is turned off and disconnected? A. Static electricity could damage the grounding system B. Circulating currents inside the transformer might cause damage C. The fuse might blow if you remove the cover D. You might receive an electric shock from stored charge in large capacitors

  24. T0A13 What safety equipment should always be included in home-built equipment that is powered from 120V AC power circuits? A. A fuse or circuit breaker in series with the AC “hot” conductor B. An AC voltmeter across the incoming power source C. An inductor in series with the AC power source D. A capacitor across the AC power source

  25. T0B10 Which of the following is true concerning grounding conductors used for lightning protection? A. Only non-insulated wire must be used B. Wires must be carefully routed with precise right-angle bends C. Sharp bends must be avoided D. Common grounds must be avoided

  26. T0B11 Which of the following establishes grounding requirements for an amateur radio tower or antenna? A. FCC Part 97 Rules B. Local electrical codes C. FAA tower lighting regulations D. Underwriters Laboratories’ recommended practices

  27. RF exposure Section 9.2

  28. High energy (high frequency) EM waves carry enough energy to detach electrons from their atoms. Examples of this type of EM wave are X-rays and gamma rays. EM waves at Radio Frequencies (RF) are non-ionizing radiation (T0C01)

  29. Safe levels of exposure have been established by the FCC. These are the Maximum Permissible Exposure levels (MPE).

  30. RF energy can only cause injury to the human body if the combination of frequency and power causes excessive energy to be absorbed. A type of heating of human tissue can occur as a result of absorption of RF energy. (Like a microwave works)

  31. Absorption varies with frequency because the body absorbs more RF energy at some frequencies than others. (T0C05) The total amount of RF absorption depends on the intensity of the RF field and the frequency of the wave.

  32. The absorption rate depends on the size or the body or the body part affected. The absorption rate is highest where the body (parts) are naturally resonant. Full Body 35 MHz if grounded 70 MHz is not grounded Head only 400MHz

  33. Above and below the ranges of highest absorption the body responds less. The MPE is lowest at 50MHz (T0C02)

  34. Duty cycle is another factor that determines safe RF radiation exposure levels. It is determined by averaging time transmitter is keyed. (T0C10)

  35. Duty cycle refers to the ratio of on-air time to total operating time of a transmitted signal. (T0C11)

  36. Therefore the factors that affect the RF exposure of people near an amateur station antenna are: • Frequency and power level of the RF field • Distance from the antenna to a person • Radiation pattern of the antenna (T0C04)

  37. FCC rules requires all fixed stations to perform an exposure evaluation. Three ways to do this: (T0C06) by calculations based on FCC OET bulletin 65 by calculations based on computer modeling by measurements using calibrated equipment

  38. VHF station operating with a power level over 50 watts PEP at the antenna are required to perform an RF exposure evaluation.

  39. The best way to make sure your station stay in compliance with RF safety regulations is to re-evaluate your station whenever an item of equipment is changed.

  40. RF burns have occurred by touching conducting surfaces (antenna) with high RF voltage present (during transmissions) (T0C07) This type of burn can be eliminated by proper grounding of the antenna or preventing (accidental) access to the antenna.

  41. The best way amateur operators can prevent exposure to RF radiation in excess of FCC limits is to relocate antennas.

  42. T0C01 What type of radiation are VHF and UHF radio signals? A. Gamma radiation B. Ionizing radiation C. Alpha radiation D. Non-ionizing radiation

  43. T0C02 Which of the following frequencies has the lowest Maximum Permissible Exposure limit? A. 3.5 MHz B. 50 MHz C. 440 MHz D. 1296 MHz

  44. T0C03 What is the maximum power level that an amateur radio station may use at VHF frequencies before an RF exposure evaluation is required? A. 1500 watts PEP transmitter output B. 1 watt forward power C. 50 watts PEP at the antenna D. 50 watts PEP reflected power

  45. T0C04 What factors affect the RF exposure of people near an amateur station antenna? A. Frequency and power level of the RF field B. Distance from the antenna to a person C. Radiation pattern of the antenna D. All of these choices are correct

  46. T0C05 Why do exposure limits vary with frequency? A. Lower frequency RF fields have more energy than higher frequency fields B. Lower frequency RF fields do not penetrate the human body C. Higher frequency RF fields are transient in nature D. The human body absorbs more RF energy at some frequencies than at others

  47. T0C06 Which of the following is an acceptable method to determine that your station complies with FCC RF exposure regulations? A. By calculation based on FCC OET Bulletin 65 B. By calculation based on computer modeling C. By measurement of field strength using calibrated equipment D. All of these choices are correct

  48. T0C07 What could happen if a person accidentally touched your antenna while you were transmitting? A. Touching the antenna could cause television interference B. They might receive a painful RF burn C. They might develop radiation poisoning D. All of these choices are correct

  49. T0C08 Which of the following actions might amateur operators take to prevent exposure to RF radiation in excess of FCC-supplied limits? A. Relocate antennas B. Relocate the transmitter C. Increase the duty cycle D. All of these choices are correct

  50. T0C09 How can you make sure your station stays in compliance with RF safety regulations? A. By informing the FCC of any changes made in your station B. By re-evaluating the station whenever an item of equipment is changed C. By making sure your antennas have low SWR D. All of these choices are correct

More Related