蓋革計數器說明 --- 基本度量. 蓋革計數器 (Geiger counter)又叫 蓋革-米勒計數器 (Geiger-Müller counter) ,如圖 1. ,是一種用於探測電離輻射的粒子探測器,通常用於探測α粒子和β粒子,也有些型號蓋革計數器可以探測γ射線及X射線。. 圖 1. 實驗前請確認 :. 儀器主機與探測頭的連接線是否已經接上。 將輻射源 Co 60 放置於白色置放片中心的凹槽,如圖 2. 。 將白色置放片於最接近探測頭的最上一層處,如圖 3. 。. 圖 2. 圖 3. 使用步驟. 按壓 ”POWER 開關 ” ,使 power 鈕的燈源亮起。

Download Presentation

蓋革計數器說明 --- 基本度量

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 蓋革計數器說明---基本度量 • 蓋革計數器(Geiger counter)又叫蓋革-米勒計數器(Geiger-Müller counter),如圖1.,是一種用於探測電離輻射的粒子探測器,通常用於探測α粒子和β粒子,也有些型號蓋革計數器可以探測γ射線及X射線。 圖1.

  2. 實驗前請確認: 儀器主機與探測頭的連接線是否已經接上。 將輻射源Co60放置於白色置放片中心的凹槽,如圖2.。 將白色置放片於最接近探測頭的最上一層處,如圖3.。 圖2. 圖3.

  3. 使用步驟 按壓”POWER開關”,使power鈕的燈源亮起。 檢查”STOP開關”的燈源是否亮著,若沒亮起請按壓開關使燈亮起。 檢查High Voltage的COARSE是否設定在600,另一個FINE旋鈕設定在0。 按下”RESET開關”,並設定count interval minutes為0.5 按下“COUNT開關”,當“STOP開關的燈亮起時”記錄下儀器數值。 重複步驟5,共取50組數據。 注意事項: 此儀器需要熱機30分鐘