1 / 10

Residential New Construction (NC): Slab Insulation UES Measure Update

Residential New Construction (NC): Slab Insulation UES Measure Update. Regional Technical Forum December 17, 2013. Residential NC Slab Insulation : Measure Overview. Current Category: Proven Current Status: Under Review Current Sunset Date: December 31, 2013

xanti
Download Presentation

Residential New Construction (NC): Slab Insulation UES Measure Update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Residential New Construction (NC):Slab InsulationUES Measure Update Regional Technical Forum December 17, 2013

  2. Residential NC Slab Insulation: Measure Overview • Current Category: Proven • Current Status: Under Review • Current Sunset Date: December 31, 2013 • Reason for Update/Review: Response to recommendation memo; sunset date • Baseline Type: Current Practice

  3. Staff Highlighted Areas • None

  4. Summary of Updates • Recommendation memo updates made • Updated workbook to use latest ProCosttemplate • Updated workbook to include complete SEEM model inputs and outputs for each scenario investigated • Clarified measure definition as only applicable to Montana and Heating Zone 3 • Recalculated savings using the updated and calibrated SEEM Version 0.94 • Updated baseline inputs to reflect the latest Montana Energy Code • Removed extraneous SEEM runs from workbook

  5. Summary of Updates (continued) • Recommendation memo updates not made directly in measure workbook • Documentation of SEEM calibration • This documentation is captured separately on RTF website • Documentation of all new construction SEEM inputs • Staff has created a centralized workbook with New Construction baseline assumptions • Slab insulation measure workbook contains detailed documentation of SEEM inputs relevant to the measure

  6. Current Montana Code for Slab Insulation • If foundation is slab-on-grade, and slab is less than 12 inches below grade: • Code requires R-10 slab insulation on perimeter • Insulation needs to extend 4 ft by any combination of vertical and horizontal placement (see next slide for illustration)1 • If slab is greater than 12 inches below grade (e.g. full basement), no slab insulation is required 1 Applies to slabs without in-floor heat. Heated slabs required R-15 slab insulation by MT code.

  7. Current Montana Code for Slab Insulation (continued) Slab-On-Grade Code Options Combination horizontal and vertical case Vertical case Horizontal case

  8. Current Montana Code for Slab Insulation (continued) Baseline and Efficient Cases Modeled

  9. Summary of Changes • Savings decreased by 28 to 37% depending on HVAC type: • Zonal electric: 33% • Forced air furnace: 37% • Heat pump: 28% • No change in incremental costs other than adjustment from 2008$ to 2006$ • All measures remain cost-effective

  10. Decision “I _______________ move that the RTF: • approve the Residential New Construction: Slab Insulation measure as a Proven UES; • Set the measure status to ‘Active;’ and • Set the sunset date to December 31, 2016.”