LIMIT ERROR Batas kekeliruan yang di izinkan

LIMIT ERROR Batas kekeliruan yang di izinkan. BILA : q 1 = kuantitas sesungguhnya q = kuantitas terukur q e = limit error MAKA : 1). q = q 1 ± q e (satuan besaran) 2). q = q 1 ( 1 ± % q e / 100 ) -=> % 3). q = q 1 ( 1 ± e ) dimana e = q e / q 1

yahto
Download Presentation

LIMIT ERROR Batas kekeliruan yang di izinkan

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. LIMIT ERRORBatas kekeliruan yang di izinkan BILA : q1 = kuantitas sesungguhnya q = kuantitas terukur qe = limit error MAKA : 1). q = q1 ± qe(satuan besaran) 2). q = q1 ( 1 ± %qe/100 )-=> % 3). q = q1 ( 1 ± e ) dimana e = qe / q1 q = q1 ( 1 ± qe / q1 ) q = q1 ± qe

  2. SATUAN LIMIT ERROR: • Besaran yang digunakanmisalnyategangandlm Volt  V = 220V ± 22V. • Persentase %  V = 220V ± 10% • Frictional (pecahan) e = qe / q1 = 22/220 = 0,10 V = 220V(1 ±0,10 ) • V = 220V ± 22V. • V = 220V ± 10%. • V = 220V(1 ±0,10 )

  3. Sebuah voltmeter 0–150 V membaca tegangan suatu sumber 100 V. Meter yang digunakan adalah meter kelas 1.0 (kesalahaan digaransi ± 1 %. dari skala penuh). Berapa % eror meter pada pembacaan 100 V, 50 V, 25 V dan 10 V ? Penyelesaian: Limit error = 1% x150 V = 1,5 V. Fracional limit error pada 100V: e = 1,5 /100 = 0,015. Dapat ditulis V = 100 ( 1 ± 0,015 ) atau V= 100 ± 1,5 V . Limit error dalam %  % qe = 1,5/100 x 100% Jadi pada pembacaan 100V , % error = 1,5 %

  4. Pada pembacaan 50 V , % limit error adalah % qe = 1,5 / 50 x 100% = 3 % • Pada pemb 25 V, %qe= 1,5/25 x100% = 6 %. • Pada pembacaan 10 V, % qe = 1,5 / 10 x100% = 15 % Kesimpulan : Makin dekat pembacaan alat ukur dengan batas ukurnya makin kecil kesalahannya.

  5. Tulis satuan errornya dalam bentuk lain ! • I = 3A ± 5% 6. P = 5 W ± 0,01W I = 3A ± 0,15A 2. V= 220V(1± 0,1) 7. R =15Ω ± 2 % 3. I = 10A ± 0,05A 8. V = 100V ± 1 V 4. R= 250 Ω ± 2,5 Ω 9. P = 75 W ± 7 % 5. F = 50Hz ± 1,5 % 10. R= 500 Ω (1±0,01)

  6. OPERASI HITUNG LIMIT ERROR • PENJUMLAHAN: bila: qa = q1a± qea qa = q1a ( 1 ± ea ) qb = q1b± qeb qb = q1b ( 1 ± eb ) --------------------------+ qa + qb = (q1a + q1b)( 1 ± ea + b ) qa + b = (q1a + q1b){ 1 ± (qea + qeb) / (q1a + q1b)} Atau qa + b = (q1a + q1b) ± (qea + qeb) Ia = 20 A ± 1,5 A Ib = 25 A ± 0,5 A jadi: Ia + Ib = 45 A ± 2 A

  7. 2. PENGURANGAN. qa – qb = (q1a – q 1b)( 1 ± ea – b ) atau qa – b = (q1a – q1b ) ± (qea + qeb) Va = 240 V ± 2,4 V Vb = 100V ± 2 V Jadi : Va – Vb = 140 V ± 4,4 V

  8. 3. PERKALIAN. qa.b = (q1a . q1b ) ± (%qea + %qeb) V = 500 V ± 1% I = 5 A ± 0,5 % Vx I = P = 2500 W ± 1,5 %

  9. 4. BAGI qa/b = (q1a/q1b ) ± {%(qea) – %(qeb)} V = 400 V ± 2,5 % I = 10 A ± 1 % V / I = R  R = 40 Ω± 1,5 %

  10. Latihan: 1. Hitung tahanan pengganti bila R1 = 750Ω ± 75Ω dan R2= 500 Ω ±10% terhubung: a.seri b.paralel. 2.Tentukan nilai limit error Rx dari rangkaian Jembatan Wheatston yg mempunyai lengan pembanding R1= 250 Ω± 10%; dan R2 = 500Ω ± 25Ω ; R3= 1500 Ω ± 30Ω . 3.Tentukan rugi daya dan efisiensi trafo yang memp. input 5000W ± 1% dan output 4800W ± 20W.(0,42%) 4.Motor listrik berkekuatan P=1HP ± 15 % memp.data sbb:V= 220 V ± 22 V , F=50 Hz. Tentukan arus I yang dibutuhkan bila Cos φ = 0,8 ± 4% agar dpt memikul beban sebesar kemampuanmaksimumnya. 1 HP = 746 WATT ± 15 % P=V X I X COSØ

  11. Hitung tahanan pengganti bila R1 = 750Ω ± 75Ω dan R2= 500 Ω ±10% terhubung: a.seri b.paralel. Kamis jam 1.30 Jumat jam 8.50