40 likes | 56 Views
Bluon Energy LLC develops and manufactures energy-focused HVAC refrigerants. It provides TdX 20 for commercial and residential air conditioning and heat pumps. The company was incorporated in 2011 and is based in McClellan, California.
E N D
DATA SHEET Bringing energy efficiency and a lower carbon footprint to HVAC-R. Bluon TdX™ 20 is a new generation of refrigerant delivering substantial energy savings, equal to or better R-22 capacity and easy installation. Bluon TdX 20 is a patent-pending, energy-focused refrigerant replacement for R-22 HVAC equipment. TdX 20 is the only refrigerant purpose built for energy efficiency, equal to or superior cooling capacity and cost savings. When it comes to options for eliminating R-22 to achieve environmental compliance there are essentially two choices: 1) Replace the R-22 units with new R-410A equipment; or 2) Replace the R-22 refrigerant and keep the existing equipment until the end of its lifespan. While R-410A equipment is the industry’s answer for achieving R-22 phase-out compliance, the cost at $2,500 per ton is a drawback. Replacing the R-22 refrigerant only is a more cost effective option, particularly when your equipment has remaining lifespan. But not all R-22 replacement refrigerants are alike. Most consume more energy, provide less capacity or require an oil change. And then there's Bluon TdX 20, created to be the R-22 replacement answer. When you install TdX 20, you attain environmental compliance, maintain capacity and save energy. Bluon TdX 20 Advantages Reduces energy consumption in HVAC equipment an average of 20% through lower amp draw and reduced equipment run time. Complies with R-22 phase-out as a non-ozone depleting refrigerant. Delivers equipment capacity equal to, or greater than, R-22. Extends equipment life through lower operating pressures, reduced compressor temperatures and shorter cycle times. Is the only alternative refrigerant that pays for itself, through lower energy consumption, providing an attractive financial return with a payback of ~24 months of operations. Improves overall system performance through faster more consistent cooling. TdX Data Sheet
TdX 20 Saves Energy, Lowers Your Building’s Carbon Footprint TdX 20 was purposely designed with an energy conservation focus. Third party engineering studies and hundreds of field tests validate TdX’s average energy savings of 20%. The kWh savings is achieved through reduced amp draw at the compressor combined with a shorter compressor cycle time. TdX 20’s composition reduces the time it takes an HVAC unit to reach optimal cooling/heating temperature and thus decreases the amount of time and electricity needed to cool or heat a space. With the reduction in energy consumption using TdX 20, a substantial decrease in CO2 emissions from electricity generation is realized, significantly reducing your building’s carbon footprint. Performance Benefits HVAC equipment running TdX 20 uses 20% less energy on average. Decreases unit amp draw by 5–25% and daily run time from 20–90 minutes. Decreases energy consumption during utility peak load times. Runs in low, medium and high temperature systems. Optimized for medium and high temperature equipment. Preserves or increases the cooling capacity compared to R-22. Installation and Equipment Benefits Extends the life of your current R-22 equipment through lower pressures, lower compressor operating temperatures and less run time. Works with standard metering devices. No expansion device change is required. Works with standard compressor oils including POE, AB and MO. No oil change required. Runs on all R-22 HVAC equipment Avoids a significant capital investment for new R-410A equipment. Environmental Benefits Non-ozone depleting. GWP of 1,650, the lowest GWP for R-22 replacement refrigerants available. Non-flammable and non-toxic. Helps property owners gain points toward LEED certification. A 100,000 sq. ft. building replacing R-22 with Bluon TdX 20 will reduce its carbon footprint by 60 metric tons of CO2 per year as illustrated in a third party engineering study. 2 TdX Data Sheet
Achieve a 24-Month Payback Using Bluon TdX 20 Bluon TdX 20 delivers a return on investment in approximately 24 months of operations. This payback was calculated based on average amp and run time savings, average installation costs and average electricity kW rates. ROI and payback gures are calculated based on average energy savings and installation costs. About Bluon Energy Bluon Energy is an energy-focused refrigerant developer and manufacturer with fresh ideas for products that deliver superior energy performance in an environmentally friendly way. Our current innovations go beyond being just another R-22 replacement refrigerant. We’ve created TdX to be the R-22 answer. The challenge facing the HVAC-R industry is to provide an e for the environment, energy e researching solutions for systems over a decade ago. This research led to Bluon’s next-generation R-22 refrigerant replacement, Bluon TdX 20. Bluon Energy refrigerants deliver equal to or greater cooling capacity, consume less energy and result in an ROI of approximately 50% with a payback in 24 months of operations. Contact Bluon Energy at 1-855-425-8686 or info@bluonenergy.com. Visit us at www.bluonenergy.com. ective cooling solution that is positive ective. The Bluon Energy innovation team began cient and cost e 3 TdX Data Sheet
TdX 20 Temperature/Pressure Data PSIG Temp Pressure (psig) Temp Pressure (psig) Temp Pressure (psig) ºC 10.6 11.1 11.7 12.2 12.8 13.3 13.9 14.4 15.0 15.6 16.1 16.7 17.2 17.8 18.3 18.9 19.4 20.0 20.6 21.1 21.7 22.2 22.8 23.3 23.9 24.4 25.0 25.6 26.1 26.7 27.2 27.8 28.3 28.9 29.4 30.0 30.6 31.1 31.7 32.2 32.8 33.3 33.9 34.4 35.0 35.6 36.1 36.7 37.2 37.8 ºC 38.3 38.9 39.4 40.0 40.6 41.1 41.7 42.2 42.8 43.3 43.9 44.4 45.0 45.6 46.1 46.7 47.2 47.8 48.3 48.9 49.4 50.0 50.6 51.1 51.7 52.2 52.8 53.3 53.9 54.4 55.0 55.6 56.1 56.7 57.2 57.8 58.3 58.9 59.4 60.0 60.6 61.1 61.7 62.2 62.8 63.3 63.9 64.4 65.0 65.6 ºC Liquid 22.6 23.4 24.2 25.1 25.9 26.8 27.6 28.5 29.4 30.3 31.2 32.2 33.1 34.1 35.1 36.1 37.1 38.1 39.2 40.2 41.3 42.4 43.5 44.6 45.8 46.9 48.1 49.3 50.5 51.7 53.0 54.2 55.5 56.8 58.1 59.5 60.8 62.2 63.6 65.0 66.4 67.8 69.3 70.8 72.3 73.8 75.4 76.9 78.5 80.1 81.7 Vapor 13.5 14.1 14.8 15.5 16.1 16.9 17.6 18.3 19.0 19.8 20.6 21.3 22.1 22.9 23.8 24.6 25.5 26.3 27.2 28.1 29.0 29.9 30.9 31.8 32.8 33.8 34.8 35.8 36.8 37.8 38.9 40.0 41.1 42.2 43.3 44.5 45.6 46.8 48.0 49.2 50.5 51.7 53.0 54.3 55.6 56.9 58.3 59.6 61.0 62.4 63.8 ºF 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Liquid 83.4 85.0 86.7 88.4 90.2 91.9 93.7 95.5 97.3 99.2 101.0 102.9 104.8 106.8 108.7 110.7 112.7 114.7 116.8 118.8 120.9 123.1 125.2 127.4 129.6 131.8 134.1 136.3 138.6 141.0 143.3 145.7 148.1 150.5 153.0 155.5 158.0 160.5 163.1 165.7 168.3 170.9 173.6 176.3 179.1 181.8 184.6 187.5 190.3 193.2 Vapor 65.3 66.7 68.2 69.7 71.3 72.8 74.4 76.0 77.6 79.2 80.9 82.5 84.2 86.0 87.7 89.5 91.3 93.1 94.9 96.8 98.6 100.6 102.5 104.4 106.4 108.4 110.5 112.5 114.6 116.7 118.9 121.0 123.2 125.4 127.7 129.9 132.2 134.5 136.9 139.3 141.7 144.1 146.6 149.1 151.6 154.1 156.7 159.3 162.0 164.7 Liquid 196.1 199.0 202.0 205.0 208.1 211.1 214.2 217.3 220.5 223.7 226.9 230.2 233.4 236.8 240.1 243.5 246.9 250.4 253.8 257.4 260.9 264.5 268.1 271.8 275.5 279.2 282.9 286.7 290.6 294.4 298.3 302.3 306.2 310.3 314.3 318.4 322.5 326.7 330.9 335.1 339.4 343.7 348.0 352.4 356.9 361.3 365.8 370.4 375.0 379.6 Vapor 167.4 170.1 172.9 175.6 178.5 181.3 184.2 187.2 190.1 193.1 196.1 199.2 202.3 205.4 208.6 211.7 215.0 218.2 221.5 224.9 228.2 231.7 235.1 238.6 242.1 245.7 249.2 252.9 256.6 260.3 264.0 267.8 271.6 275.5 279.4 283.4 287.4 291.4 295.5 299.6 303.8 308.0 312.2 316.5 320.8 325.2 329.7 334.1 338.7 343.2 ºF ºF 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 -17.8 -17.2 -16.7 -16.1 -15.6 -15.0 -14.4 -13.9 -13.3 -12.8 -12.2 -11.7 -11.1 -10.6 -10.0 -9.4 -8.9 -8.3 -7.8 -7.2 -6.7 -6.1 -5.6 -5.0 -4.4 -3.9 -3.3 -2.8 -2.2 -1.7 -1.1 -0.6 0.0 0.6 1.1 1.7 2.2 2.8 3.3 3.9 4.4 5.0 5.6 6.1 6.7 7.2 7.8 8.3 8.9 9.4 10.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 The information provided herein is based on technical data that Bluon Energy believes to be reliable. Conditions of product use are outside our control; therefor we make no warranties, expressed or implied, and assume no liability in connection with any use of this information. Bluon Energy and Bluon TdX are trademarks of Bluon Energy LLC. All other trademarks are the property of their respective owners. All rights reserved. © 2015 Bluon Energy 4 TdX Data Sheet