1 / 46

PremiSys Setup Review

PremiSys Setup Review The following sequence presents the minimum configuration necessary to obtain an “Access Granted” in a newly installed PremiSys system. Remember, your system settings may differ for reader type, card format, controller address, etc; and not all system settings are covered.

Faraday
Download Presentation

PremiSys Setup Review

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PremiSys Setup Review The following sequence presents the minimum configuration necessary to obtain an “Access Granted” in a newly installed PremiSys system. Remember, your system settings may differ for reader type, card format, controller address, etc; and not all system settings are covered. PremiSys Setup Review ends with trouble-shooting tips for fixing the most common card failure transactions. Our goal is to produce an “Access Granting” transaction. Let’s begin…

  2. Contents First-Time Users: Please press <Enter> to move from start to finish. Press <Backspace> at any point to back up. Returning Users: Click a topic name below to jump ahead Go to Access Settings Create 24/7 Time Zone Activate Card Format Configure Card Database Add Site Add Channel Add Controller Add I/O Board Edit Reader Edit Door Set up Access Group Download Controller Create Card Assign Card Access Rights Test the CardTrouble-shooting Tips

  3. Download

  4. Present card; see “Access Granting”

  5. Host Offline – check settings for: channel (COM), controller, and I/O board No transactions at all – download (also required after system setting changes) Reader beeps, but no transactions appear – check Weigand pulse in reader setup “Invalid Card Format” – check card format setup, confirm format is assigned to door “Invalid Site Code” – check door’s card format(s), update format w/correct site code “Card not in Controller” – assign the card number to a cardholder “Card has no access at anytime” – assign an access group to the card “Access denied: Invalid time” – check time zone and/or access level settings Can’t find cardholder to update card – Go to navigator, click , search by name Card database error – create/modify one and/or assign one to the controller Wrong lock relay, door position input, and/or RTE are associated with the reader – “Generate Door” feature assumes the first reader’s associated points are: first relay is door lock; first input is RTE; second input is door position. (If different, update settings in the “Door” tab in the door setup window.) Trouble-shooting Tips