Benchtop Water Hardness Meter

Benchtop Water Hardness Meter meter comes with a UK electrode. Stability indicator automatically shows present working status. It measures salts of calcium and<br> other elements at mg/L, mml/ scale which causes hardness water. Automatic electrode diagnosis indicates the slope of sensor. It is equipped with large backlit <br>LCD display, 2 to 5 points calibration with low to high concentration range. Stored data can be transferred into computer by using USB communication interphase.

Kimber4
Download Presentation

Benchtop Water Hardness Meter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Benchtop Water Hardness Meter www.labmate.com | info@labmate.com Overview

  2. Benchtop comes with a UK electrode. Stability indicator automatically shows present working status. It measures salts of calcium and other elements at mg/L, mml/ scale which causes hardness water. Automatic electrode diagnosis indicates the slope of sensor. It is equipped with large display, 2 to 5 points calibration with low to high concentration range. Stored data can be transferred into computer by using USB interphase. Water Hardness Meter backlit LCD communication Specifications : Range (Concentration) 0.05 to 200 mmol/L Range (German 0 to 1122°dH Degree)

  3. Range (English Degree) 0 to 1404°e Range (French Degree) 0 to 2000°fH Range (CaCO3) 0 to 19999 mg/L Range (CaO) 0 to 11220 mg/L Range (Boiler) 0 to 400mmol/L Range (Ca2+) 0 to 8020 mg/L Resolution 0.001, 0.01, 0.1, 1 Accuracy ±1% F.S. Calibration Points 2 to 5 points Calibration Solutions 0.01, 0.1, 1, 10, 100mmol/L Temperature Range 0 to 105°C Temperature Resolution 0.1°C

  4. Temperature Accuracy ±0.5°C Offset Calibration 1 point Calibration Range Reading ±10°C Temperature 0 to 50°C, manual or automatic Compensation Stability Criteria Low or high Calibration Due Alarm 1 to 31 days or off Memory Stores up to 500 data sets Output USB communication interface Connector BNC, 3.5 mm jack socket Display Custom LCD (125×100 mm) Power DC5V, using AC adapter, 220 V/50 Hz

  5. Dimensions(L×W×H) 210×188×60 mm Weight 1.5 Kg Features : - Presence of stability indicator to robotically display current status - Calibration due reminder alerts user for calibration of the meter on regular basis - System menu provided with seven parameters - Equipped with stability indicator to robotically display current measurement status - Calibration due remainder prompts user to calibrate the meter consistently - Reset feature instinctively resumes parameters back to factory default options

  6. Applications : It is widely used in testing the hardness level of tap water, drinking water, filtered water, water used for different experiments and testing across food, textile, painting and other industries Labmate Scientific Email: info@labmate.com | Website: www.labmate.com