0 likes | 8 Views
<br>Ozone Meter uses the Beer-Lambert Law for monitoring low concentrations of ozone using UV absorption. With a flow rate of 1.5L/min, they operate continuously, <br>providing real-time data. It uses advanced microprocessor technology and has a very low sampling time of 10 seconds. Offers good stability and reproducibility <br>with fast and accurate results.<br>
E N D
Ozone Meter www.labmate.com | info@labmate.com Overview Ozone Meter uses the Beer-Lambert Law for monitoring low concentrations of ozone using UV absorption. With a
flow rate of 1.5L/min, they operate continuously, providing real-time data. It uses advanced microprocessor technology and has a very low sampling time of 10 seconds. Offers good stability and reproducibility with fast and accurate results. Specifications : Ozone 0 ppm to 5 ppm, 0 ppm to 100 ppm, 0 ppm measureme to 300 ppm, 0 ppm to 600 ppm (Optional) nt range Operating 10 °C to 40 °C temperatur e Accuracy 0.01 ppm or 3 % of reading Operational 10 % to 90 % RH humidity
Flow rate 1.5 L/min Resolution 0.001 ppm Sampling 10 seconds Time Boot time ≥ 30 Gas pipe Ø 4 mm diameter Output 4 to 20 mA, 0 to 5 V DC; Modbus 485 mode Power 24 VDC ± 10 % Dimensions 150 × 90 × 325 mm
Weight 1.9 kgs Features : - Enhanced with good anti-jamming performance - Fitted with a digital display for easy interpretation of the data - Equipped with a built-in printer - Features an automatic measuring mode - Advanced with auto zero calibration for precise results - Designed to be portable and durable making it more reliable Applications : Ozone meters are used for assessing and measuring ozone concentrations in the air. They are employed in various fields like air quality monitoring, water treatment, ozone therapy, and ozone generators in pharmaceutical, chemical, and electronic industries.
Labmate Scientific Email: info@labmate.com | Website: www.labmate.com