1 / 4

Gas-chromatography-mass-spectrometry-GC-MS-879.

<br>Labtron Gas chromatography mass spectrometry is designed a mass analyzer with a pre-filter and controlled electron flow, analyzing up to 1000 compounds in a single run. It operates at 100u2013350u00b0C with a flow rate of 1u20131.5 ml/min and includes seven-stage temperature programming. An auto sampler allows for simultaneous identification and analysis of different compounds rapidly.

LabtronUS
Download Presentation

Gas-chromatography-mass-spectrometry-GC-MS-879.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gas chromatography mass spectrometry GC-MS-879 www.labtron.us |info@labtron.us

  2. Overview Gas chromatography mass spectrometry GC-MS is a high precision Gas chromatograph mass spectrometer with pre-filter mass analyzer and electron multiplier ensuring high sensitivity. Desorption of solids is performed at controlled temperature between 100 ~350 °C with a flow rate of 1 to 1.5 ml / min. With seven stage temperature programming and an interface temperature of 450 °C the analysis is sensitive and specific. Specifications: Model No GC-87 Gas Chromatography Specifications Flow rate 1 ~ 1.5 ml / min Maximum flow rate 10 ml / min Inlet 450 °C temperature Pressure range 0 ~ 100 psi Heating rate Upto 120 °C / min Room 4 °C ~ 450 °C temperature Pressure control mode Electronic pressure control ( Supports CV and CC ) Split mode Split/splitless Split ratio 1000 : 1 Temperature programming 7 stages / 8 platforms Auto sampler Optional

  3. Mass Spectrometry Specifications Model No MS-89 Mass range 1.5 ~ 1000 amu 100 °C ~ 350 °C Ion – source temperature GC-MS interface temperature 450 °C Scan rate Upto 10000 amu/s Stability ± 0.10 amu / 48 hrs. 0 ~ 350 µA Filament emission current 5 eV ~ 250 eV EI source ionization energy Resolution Unit resolution Detector High energy dynode electron multiplier Sensitivity Full scan ( S / N is ≥ 30 : 1 ) Vacuum Turbo molecular pump ( 67 L/s )

  4. Features Column flow rate is 1 ~ 1.5 ml / min Maximum flow rate is 10 ml / min Simultaneous analysis with different components increasing productivity Electronic flow control system Mass analyzer with pre-filter reducing quadruple filtration Turbo molecular pump vacuum system for stability and reliability Software controlled auto sampler, gas chromatograph and mass spectrometer Screens and quantifies more than 1000 compounds in a single run Applications : Used in identifying and quantifying volatile organic compounds in mixtures, testing residual solvents, identification of trace impurities in liquids or gases, evaluating extracts from plastics, contaminants on semiconductor wafers or other technology products Labtron Equipment Ltd.Quatro House,Lyon Way,Camberley,SurreyGU16 7ER, United Kingdom Email: info@labtron.us |Website: www.labtron.us Phone: +44 2080 043 608