1 / 11

Kirloskar Gensets - Reliable and Efficient Power Solutions for Every Need

Explore reliable power solutions with Myspan Power's Kirloskar gensets. Designed for maximum efficiency and durability, these gensets are perfect for fulfilling the power needs of industrial, commercial, and residential settings.<br>

Myspanpower
Download Presentation

Kirloskar Gensets - Reliable and Efficient Power Solutions for Every Need

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 50Hz GENSET SERIES

  2. A RICH HERITAGE OF OVER A CENTURY OF ENGINEERING EXCELLENCE. Kirloskar power generating sets prioritize user experience, delivering exceptional features and benefits. Streamlined installation and enhanced dependability to expedited service, A RICH HERITAGE OF OVER A CENTURY OF reduced maintenance costs, and optimized performance. ENGINEERING EXCELLENCE. Kirloskar Powergen sets itself apart with groundbreaking engineering that establishes new industry benchmarks. Kirloskar power generating sets prioritize user experience, delivering exceptional features and benefits. Streamlined installation and enhanced dependability to expedited service, POTENTIAL, SUSTAINABLE PRACTICES reduced maintenance costs, and optimized performance. Kirloskar Powergen sets itself apart with groundbreaking engineering that establishes new industry benchmarks. POTENTIAL, SUSTAINABLE PRACTICES Our state-of-the-art manufacturing facility embodies our commitment to sustainable practices. We partner with nature to power the facility itself, transforming waste into valuable resources. This focus on sustainability inspires both our workforce and surrounding communities. It's here, where cutting-edge technology meets exceptional skills, that we engineer solutions to empower limitless possibilities. Discover our Plant with a QR Code Scan.

  3. 5 0 H z 50 HERTZ D I E S E L G E N E R A T O R THE VERSATILE POWER GENERATOR SOLUTION AGRICULTURE CONSTRUCTION HEALTHCARE HOSPITALITY MANUFACTURING DATA CENTRES MINING REAL ESTATE

  4. F E A T U R E S Unmatched Features Reduced Emissions Low Fuel Consumption Low Maintenance Cost Extended Service Intervals 500 Hours Service Interval* Easy Installation Subject to usage of 15W40-CI4 grade oil *Basis the applicable model and geography

  5. GENERATING SETS Open 17W50 22W50 33W50 44W50-3 44W50-4 69W50 91W50 110W50 138W50 176W50 220W50 275W50 352W50 440W50 550W50 660W50 825W50 1111W50 Model 17WS50 22WS50 33WS50 44SW50-3 44SW50-4 69WS50 91WS50 110WS50 138WS50 176WS50 220WS50 275WS50 352WS50 440WS50 550WS50 660WS50 825WS50 1111WS50 SAE 415 415 415 415 415 415 415 415 415 415 415 415 415 415 415 415 415 415 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 380 400 L-L V Voltage 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 220 230 240 L-N V 16.5 33 44 44 69 91 110 138 176 220 275 352 440 550 660 825 1111 kVA 22 Standby ESP 55 13.2 17.6 26.4 35.2 35.2 72.6 88 110 140.8 176 220 281.6 352 440 528 660 888.8 kW Power Output 15 20 30 40 40 62.5 82.5 100 125 160 200 250 320 400 500 600 750 1010 kVA Prime Power PRP 16 2.6 3.6 4.7 62 32 5.1 6.9 9.1 95 32 5.1 6.9 9.1 95 50 7.6 10.8 14.4 158 66 9.7 13.8 18.3 158 80 10.7 17.7 22.5 225 100 15.5 20.7 26.8 230 128 19.1 25.0 34.0 275 160 24 31.9 42.3 340 200 29.8 41.9 55.1 350 256 40.5 55.3 70.8 552 320 46.4 61.6 80.4 552 400 61.2 75.6 97 680 480 70.7 92.7 123.7 900 600 83 115 152 880 808 120.6 161 208 410 kW L/Hr L/Hr L/Hr L 12 2.0 2.7 3.4 65 24 3.7 5.1 6.7 80 Output 50% 75% 100% Open Fuel Consumption (at % of PRP) Fuel Tank 40 40 70 99 97 150 150 195 195 270 325 325 560 560 870 930 1350 900 SAE L Capacity Sound Level at 7m 75 75 70 70 70 70 70 70 70 70 70 70 70 70 70 70 80 80 SAE dB (A) cm 141 x 104 x 133 141 x 104 x 133 150 x 109 x 134 175 x 100 x 118 175 x 100 x 118 211 x 106 x 146 211 x 106 x 146 220 x 107 x 169 220 x 107 x 169 260 x 102 x 184 311 x 154 x 170 311 x 157 x 207 339 x 166 x 220 340 x 166 x 222 365 x 184 x 235 379 x 200 x 234 398 x 230 x 240 454 x 210 x 251 Open Dimensions (LxWxH) cm 218 x 101 x 145 198 x 97 x 123 218 x 101 x 145 262 x 111 x 158 262x 111 x 158 297 x 116 x 166 297 x 116 x 166 327 x 116 x 193 327 x 116 x 193 372 x 116 x 203 437 x 162 x 198 436 x 167 x 223 498 x 211 x 228 498 x 211 x 228 525 x 212 x 257 566 x 211 x 257 580 x 230 x 253 687 x 230 x 250 SAE (as per GA Drawing) kg 650 700 790 840 840 1100 1200 1450 1510 1910 2320 2620 4250 4550 4750 5200 5880 8650 Open Dry Weight (net) kg 920 970 1100 1310 1310 1630 1950 2120 2180 2720 3440 3670 6000 6300 7100 7830 7850 13200 SAE Approx. KIRLOSKAR ENGINE (LIQUID COOLED, 4 STROKE, DIESEL ENGINE) Model 2R1040 2R1040 3R1040 3R1040TA 4R1040 4R1040TA 4K1080TA 4K1080TA 6K1080TA DV8 DV8 DV10 DV12 4R1040TC 6SL1500TA 6SL8800TA DV12ETAG12 DV16ETAG1 hp Engine Output 56 56 83 105 156 156 200 248 310 400 490 608 750 900 1210 PRP 27 27 42 8 - V 8 - V 10 - V 12 - V 12 - V 16 - V 4 - Inline 4 - Inline 4 - Inline 4 - Inline 4 - Inline 6 - Inline 6 - Inline 6 - Inline 2 - Inline 2 - Inline 3 - Inline 3 - Inline Cycles and Configuration mm 105 x 120 105 x 120 105 x 120 105 x 120 105 x 120 105 x 120 105 x 120 105 x 125 105 x 125 105 x 125 118 x 135 118 x 135 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150 130 x 150 Bore x Stoke 15.5:1 15.5:1 15.5:1 17.5:1 17.5:1 18:1 18:1 18:1 18:1 18:1 18:1 18:1 16.5:1 16.5:1 16.5:1 16.5:1 16.5:1 16.5:1 Compression Ratio L 2.08 2.08 3.12 3.12 3.12 4.16 4.16 4.32 4.32 6.48 8.86 8.86 15.91 15.91 19.9 23.88 23.88 31.88 Displacement Natural Natural Natural Natural TA TC TA TA TA TA TA TA TA TA TA TA TA TA Aspiration V 12 12 12 12 12 12 12 12 12 12 24 24 24 24 24 24 24 24 Starting System (DC) Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Governor G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 G2 Governor Class as per ISO8528-5 5.5 5.5 7.5 7.5 7.5 9.5 9.5 14 14 18 38 38 50 125 L 21 21 42 42 Lub Oil Sump Capacity - Refill 54 54 10 10 54 43 43 123 123 133 144 166 180 L 12 12 12 24 24 Coolant Capacity ALTERNATOR (BRUSHLESS, SELF EXCITED, 4 POLE ALTERNATOR) Make Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Stamford Leroy Somer Leroy Somer Model S0L2F1 S0L2M1 S1L2J1 S1L2N1 S1L2N1 UCI 224F1 UCI 224G1 UCI 274C1 UCI 274V1 / E1 UCI 274F1 UCI 274H1 UCI 274J1 / K1 HCI 444E1 HCI 444F1 HCI 544D1 HCI 544E1/F1 LSA49.1M75 LSA49.3L11 No. of Bearings Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Insulation Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Class H Temp. Rise at Ambient 40°C 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 125 °C Wires 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Ingress Protection IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 IP23 AVR Model D350 D350 AS540 AS540 AS540 AS540 AS540 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 AS440 Voltage Regulation % +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% +/-1% Definitions of Ratings as per ISO8528-1 - PRP - PRP ratings are applicable for supplying continuous electrical power at variable load in lieu of commercial purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload for 1 hour in 12 hours. ESP - ESP rating is defines as the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of utility power outage. This rating is applicable for 200hours of operation per year with the maintenance intervals and procedures being carried out. The permissible average power output over 24 hours of operation shall not exceed 70% of the ESP rating. No overload is permitted above ESP rating. • For site conditions other than the standard reference conditions of ISO8528-1 the derating is applicable. Please contact nearest KOEL office for the available power calculation at given site conditions. • The alternator models and controller models are of standard product and may vary as per the agreed scope. • Alternator may vary basis on requirement DI - Auto start digital input is available as standard feature • SD- Shutdown • SAE : Sound Attenuated Enclosure • ESP : Emergency Standby Power rating • PRP : Prime Rated Power rating • CT : Current Transformer • LL : Line to Line • LN : Phase to Neutral • TC : Turbocharged • TA: Turbocharged Aftercooled • AVR : Automatic Voltage Regulator • MCB: Miniature Circuit Breaker • MCCB : Moulded Case Circuit Breaker • The declared fuel consumption is calculated values with 0.845 specific gravity of diesel as per BS 2869 class A2 and confirms to ISO 3046 and has production tolerance of +5%. • The declared weight and dimensions are approximate and for transportation purpose. Actual weight and dimensions are may vary as per the agreed scope. Mentioned height is without tail pipe.

  6. OPTIPRIME GENSET TECHNICAL SPECIFICATION OPTIPRIME 2222WS50 Model 2222WS50 kVA kW kVA kW V Hz 2020 1616 2222 1777.6 415 50Hz 0.8 lagging 80 402.8 308.4 215.4 111.1 860(430X2) 25170 26000 12192 2438 2895 4002 Series Prime Power at rated rpm PRP Stand by Power at rated ESP Voltage Frequency Power factor Noise level Voltage dB (A) @7metres At 100% Load At 75% Load At 50% Load At 25% Load Fuel Consumption# L/Hr Fuel tank capacity (Standard DG set) Ltrs Kg Kg mm mm mm mm Dry Wet Length Width Height (without silencer) Height (with silencer) Weight of Genset with canopy (approx.)$ Overall dimensions of Genset^ Genset alignment/configuration ENGINE Engine Model Engine 1 DV16 ETA 889 1210 16 130 x 150 1500 16.5:1 31.84 TA 24 Electronic G2 500 130 180 55 Alternator 1 Leroy Somer KG49.3 L11 Single Class H 125 4 IP23 D350 95.1 +/-1% <20% < 2 sec provided en- gine reach the rated speed Engine 2 DV16 ETA 889 1210 16 130 x 150 1500 16.5:1 31.84 TA 24 Electronic G2 500 130 180 55 Alternator 2 Leroy Somer KG49.3 L11 Single Class H 125 4 IP23 D350 95.1 +/-1% <20% < 2 sec provided en- gine reach the rated speed kW hp Rated output (Prime Continuous rating as per ISO 8528 -1) No. of cylinder Bore x Stroke RPM Compression ratio Cubic capacity2 Aspiration Starting System Governor Governing class as per ISO 8528-5 Lube Oil change period Lube oil Sump Capacity per Engine Coolant Capacity per engine Block loading capacity ALTERNATOR Make Model No. of bearings Insulation Class Temp. rise at ambient 40 C Wires Ingress protection AVR model Alternator Efficiency (at 100% load) 0.8 pf* Voltage regulation Max Voltage Dip at Full Load 0.8 pf Lag Number mm Ltrs V hrs. Ltrs Ltrs % ° C % % 0 Max Time to build up rated voltage at Rated RPM Sec Synchronization Panel Incoming breaker Outgoing breaker Synchronization Controller** STANDARD Optional DSE8610 MKII Notes ^ Tolerences Apply # With 0.845 Specific Gravity of diesel (5% Tolerance) $ These weight are for handling & transportation only,±5% tolerance apply * Efficiency of Alternator as per standards IEC 60034-1 ** For operation of outgoing breaker higher version of Synchronization controller is required For Site Conditions other than standard operating conditions consult Kirloskar Oil Engines Ltd. For Site specific layout consult Kirloskar Oil Engines Ltd to ammend the Genset alignment/configuration

  7. CONTROL SYSTEM FEATURES AND SAFETIES Controller Module DSE4522 A2 DSE7320MKII 17W50, 22W50, 33W50, 44W50, 69W50, 91W50, 110W50, 138W50, 176W50 220W50, 275W50, 352W50, 440W50, 550W50, 660W50, 825W50, 1111W50 Model 220WS50, 275WS50, 352WS50, 440WS50, 550WS50, 660WS50, 825WS50, 1111WS50. 2222WS50 17WS50, 22WS50, 33WS50, 44WS50, 69WS50, 91WS50, 110WS50, 138WS50, 176WS50 On Display Screen DSE4522 A2 DSE7320MKII On Display Screen DSE4522 A2 DSE7320MKII Generating Set Volts, Amps. Hz Generating Set Volts, Amps. Hz Y Y Generating Set kW, kVA, kVAr Generating Set kW, kVA, kVAr Y Y Generating Set Per Phase PF Generating Set Per Phase PF Y Y Generating Set kWHr Meter Generating Set kWHr Meter Y Y Earth Current (A) Earth Current (A) N Y Grid (Mains) Voltage (L-L) Grid (Mains) Voltage (L-L) Y Y Battery Voltage (V) Battery Voltage (V) Y Y Engine Start Attempts Engine Start Attempts N Y Engine Temperature ( C) Engine Temperature ( C) Y Y Engine Speed (RPM) Engine Speed (RPM) Y Y Engine Run Hours (Hours & Min.) Engine Run Hours (Hours & Min.) Y Y Lube Oil Pressure (kPa, PSI, bar) Lube Oil Pressure (kPa, PSI, bar) Y Y Diesel Fuel Level (%) Diesel Fuel Level (%) Y Y Communication Ports DSE4522 A2 DSE7320MKII Communication Ports DSE4522 A2 DSE7320MKII RS485 RS485 Y Y RS232 RS232 N Y Y - Available N - Not Available CUSTOMIZE YOUR POWER NEEDS WITH OPTIONAL ACCESSORIES GENERATING SET ENGINE External Bulk Fuel Tank of 1000L, 5000L, 10000L, 15000L Cold Start Kit Battery Isolator Switch Fuel Transfer Pump 1000 Hours Service Interval Kit for Select Ratings Fuel Priming Manual Pump Jacket Water Heater 220V - 240V AC Fire Extinguisher Lube Oil Temperature Sensor

  8. CONTROL SYSTEM FEATURES AND SAFETIES Controller Module DSE4522 A2 DSE7320MKII Protection Ind Ind WR SD DI WR SD DI Low Oil Pressure N Y Y Y Y Y High Coolant Temperature Y Y Y Y Y Y Low Fuel Level Y Y Y Y N Y N Low Coolant Level N Y Y Y Y Under / Over Speed Y Y Y Y Y Y Low / High Battery Voltage Y N Y Y N Y Low Charge Alternator Y N Y Y N Y Emergency Stop N N Y Y Y Y Fail to Start/ Stop Warning N Y N Y Y Y Auto Remote Start/stop DI Y Y Under / Over Voltage Y Y Y Y Y Y Under / Over Frequency Y Y Y Y Y Y Over kW / Overcurrent N Y Y Y Y N Low Load N N Y Y Y N Incorrect Phase Sequence N N N N N Y Y Reverse Power N N N N N Y Y Short Circuit N N N N N Y Y Earth Fault N N N N N Y Y Not Applicable Y - Available N - Not Available WR - Warning • SD - Shutdown • Ind - Indication • DI - Digital Input CUSTOMIZE YOUR POWER NEEDS WITH OPTIONAL ACCESSORIES ALTERNATOR CONTROLS Alternator Space Heater Static Battery Charger 12V 5A / 24V 10A ATS Panel Permanent Magnet Exciter (PMG) (For Select Ratings) Dummy Load Bank Alternator Inlet Louver Filters Remote Monitoring Unit Droop Current Transformer (For Select Ratings) Synchronization Panel for Higher kVA Solutions

  9. E X T E R N A L F E A T U R E S Mesh on Exhaust Tail Pipe Prevents entry of pests / rodents Emergency Stop Switch Easily accessible on canopy for stopping Top Lifting Arrangement Easy to lift by crane Glass Window on Canopy Easy to read generating set parameters and safe Stainless Steel Door Hinges Heavy-duty, anti-corrosive and long lasting Door for Radiator Access Easy access for faster service Stainless Steel Door Handles High durability and improved security Coolant Drain Arrangement External Fuel Tank with Indicator Lamp Pockets for Forklift Facilitates easy handling and installation Easy access for faster service Ease of refuelling, prevents fuel spillage and improves safety Provision of Gland Plate Easy cable entry and improved safety

  10. I N T E R N A L F E A T U R E S Coolant Level Sensor Supplementary engine protection Heat Insulated Exhaust Improves engine cooling efficiency and serviceability Guard for Rotating and Hot Parts Increased safety Water Separator as a Standard Feature Prevents water entry into engine Lube Oil Drain Pump Faster oil drain, reduces downtime, eliminates need of additional tray Longer Fuel Tank Breather Tube Prevents fuel spillage due to overfilling High Efficiency LED Lamp Extra bright and low power consumption Dual Fuel Gauge Easy fuel level reading while re-fuelling SMF Batteries

  11. SHAPING THE FUTURE. DELIVERING POWER TO OVER 50+ COUNTRIES. INGENIOUS DESIGN. UNMATCHED PERFORMANCE. KIRLOSKAR OIL ENGINES LIMITED A Kirloskar Group Company Regd. Office: 13, Laxmanrao Kirloskar Road, Khadki, Pune, Maharashtra 411 003 INDIA Tel: +91 (20) 2581 0341 Fax: +91 (20) 2581 3208, 2581 0209 Helpline: +91 8806 33 44 33 koel.helpdesk@kirloskar.com Marks ‘Kirloskar’ along with the suffix, or prefix, ‘I’ as shown and copyright ‘limitless’ are owned Kirloskar Proprietary Limited. and Kirloskar Oil Engines L td. is the Permitted User. This Catalog is copyrighted and may not be reproduced in any form not even parts of it, without previous written permission by copyright owners, Kirloskar Oil Engines L td. Product improvement is a continuous process. Kindly contact Kirloskar Oil Engines Ltd. for latest information. Images are for illustration purposes only. IBG.X.022.REV0

More Related