Fuel Tank Lightning Protection - An Indispensable Part of the Oil Depot Safety System

Society increasingly depends on petroleum products, so storage management of crude oil and its products has become particularly important. The approach to solving the lightning induced fire issue is centred on eliminating voltage differential by installing a fuel tank lightning protection system such as LECu201ds Retractable Grounding Assembly. To receive a quote or more information, feel free to contact us: https://www.lightningprotection.com/ <br>

NicolasHale
Download Presentation

Fuel Tank Lightning Protection - An Indispensable Part of the Oil Depot Safety System

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fuel Tank Lightning Protection An Indispensable Part of the Oil Depot Safety System https:// https://www.lightningprotection.com/ www.lightningprotection.com/

  2. Prior to export, processed crude oil is stored in Floating Roof Tanks (FRT) to further allow any trapped gas within the crude oil to escape, and further stabilize the oil. In the oil and gas industry, FRT’s are vital in the processing of crude oil to the acceptable export specification. However, because of global climate change, the frequency of accidents which include equipment damage and fire damage caused by lightning in fuel depots is rapidly increasing with floating roof tank fire being a major threat to crude oil production. ” 2 https:// https://www.lightningprotection.com/ www.lightningprotection.com/

  3. Interaction of Lightning with a floating roof tank By design to ensure ease of movement of the floating roof within the tank shell, there exist a gap between By design to ensure ease of movement of the floating roof within the tank shell, there exist a gap between the tank shell and the edge of the floating roof. This eliminates friction, guarantees ease of movement but the tank shell and the edge of the floating roof. This eliminates friction, guarantees ease of movement but creates issues in the following areas when lightning strikes. creates issues in the following areas when lightning strikes. Sparking Sparking When lightning strikes a floating roof, the lightning current will flow over the roof towards the edge of the roof, and at the edge there exist a discontinuity because of the tank shell-roof gap, this prevents the current from flowing through the tank shell to the ground. Roof Roof surface surface charging Prior to an eventual lightning strike electric charges will accumulate in the sky. This creates a difference in potential between the roof and the shell which can result in transient currents. charging Heating Heating The flow of high energy lightning current can cause erosion and melting of thin metal sheets and this can generate incendiary particles even around the shell-roof gap; though tanks with a thickness greater than 5mm cannot be melted by lightning. https:// https://www.lightningprotection.com/ www.lightningprotection.com/

  4. The discussion above shows that the gap between the roof and the tank shell is a major cause of lightning voltage spark. In order to mitigate this, LEC on fuel tank lightning protection recommends RGA. Retractable Grounding Array (RGA) Retractable Grounding Array (RGA) is basically a self-retracting conductor. The RGA retracts and extends based on the roof level thereby maintaining the shortest electrical connection possible and by so prevents the issue associated with the use of long cables. It is made of multiple weaved strands of low resistance tinned copper wire and is typically installed on the tank shell and connected to the edge of the roof. 4 https:// https://www.lightningprotection.com/ www.lightningprotection.com/

  5. Society increasingly depends on petroleum products, so storage management of crude oil and its products has become particularly important. The approach to solving the lightning induced fire issue is centered on eliminating voltage differential by installing a fuel tank lightning protection system such as RGA. https:// https://www.lightningprotection.com/ www.lightningprotection.com/

  6. Contact Us…. Address: Address: 6687 Arapahoe Rd. Boulder, CO 80303, USA Phone: Phone: 303-447-2828 Email Email: : info@lecglobal.com Facebook: Facebook: https://www.facebook.com/Lightningeliminators/ Twitter: Twitter: https://twitter.com/lightningprotec Website: Website: https://www.lightningprotection.com/