100 likes | 116 Views
VMware certification exams are an all-time favorite and most coveted certification VMware Specialist: vSAN 6.x Exam Dumps - VMware 2VB-601 exams of the modern IT world. Now pass your desirable VMware 2VB-601 exam with the help of Certmagic exam dumps. We offer superlative VMware 2VB-601 Exam dumps in the form of PDF file. All VMware VMware 2VB-601 Exam Questions are newest and approved by professional experts to guarantee your success. Just visit the website to get the complete package: https://www.certmagic.com/exam/2vb-601-exams
E N D
2VB-601 ???????????????????????????????? Exam : ?????????? Demo Edition C C CE E ER R RT T T M M MA A AG G GI I IC C C 1 http://www.certmagic.com
2VB-601 QUESTION: 1 What is the result of powering on a virtual machine that is not compliant with its storage policy? A. The virtual machine powers on in read-only mode. B. The virtual machine becomes inaccessible. C. The virtual machine powers on in a suspended state. D. The virtual machine powers on successfully. Answer: B QUESTION: 2 What is the maximum supported latency between the preferred and secondary sites in a vSAN stretched cluster configuration? A. 5 milliseconds round trip time B. 10 milliseconds round trip time C. 2.5 milliseconds round trip time D. 200 milliseconds round trip time Answer: A References: http://www.yellow-bricks.com/2015/09/23/designing-a-virtual-san-stretched-cluster/ QUESTION: 3 Which two statements are true regarding storage policies? (Choose two.) A. Each VMDK within a VM may be assigned a different storage policy. B. Storage policies can be created that are not compatible with any datastores. C. Multiple storage policies can be assigned to a single VMDK. D. A maximum of four storage policies per datastore can be created. Pass Your Certification With Marks4sure Guarantee 1 Answer: A, C 2 http://www.certmagic.com
2VB-601 QUESTION: 4 A 12-node vSAN cluster has been deployed across three server racks in a data center. There are four nodes in each server rack. A vSAN fault domain has been configured for each server rack for a total of three fault domains. All virtual machines in the cluster have the vSAN default storage policy assigned to them. This policy has not been modified. vSphere HA is enabled for the cluster. One of the server racks loses power. How does this affect virtual machines running on this cluster? A. Since there are four nodes in each server rack, erasure coding is used to rebuild data that was lost due to the server rack power failure. vSphere HA monitors the rebuild process and powers on all affected virtual machines after the rebuild process is complete. B. Virtual machine data in the failed server rack is rebuilt immediately using parity information. vSphere HA powers off and restarts all of the virtual machines to rebalance storage utilization across the cluster. C. All virtual machine data remains accessible. Virtual machines running on nodes in the failed server rack are restarted on nodes in the other two server racks. Virtual machines in the other two server racks continue to run. D. Virtual machines running on nodes in the failed server rack remain offline for 60 minutes. Virtual machines in the other two server racks continue to run and are marked "Degraded". Answer: C QUESTION: 5 Which statement is true about the deduplication and compression feature in vSAN? A. Redundant blocks across multiple disk groups are NOT deduplicated. B. Compression removes redundant data blocks, whereas deduplication removes additional redundant data within each data block. C. Compression occurs as data is moved from the capacity tier to the cache tier. D. Deduplication and compression are enabled by default when the vSAN cluster is created. Answer: A QUESTION: 6 The following are configuration details for a 10-node hybrid vSAN cluster: Each node 3 http://www.certmagic.com
2VB-601 has 7 x 2 TB magnetic disks, 1 x 800 GB SSD. What is the raw capacity of this cluster as configured? A. 148TB B. Not enough information provided. Cannot be calculated. C. 140TB D. Cannot be calculated until vSAN is online. Answer: A QUESTION: 7 Which three sources can be queried to retrieve storage policy components? (Choose three.) A. vSphere API for IO Filtering (VAIO) B. Virtual Volumes (VVols) C. vCenter D. vSAN E. Storage IO Control (SIOC) Answer: B, C, D QUESTION: 8 What are two main advantages of using multiple disk groups within each host? (Choose two.) A. Performance B. Backward compatibility C. Cost D. Redundancy Answer: A, D Explanation http://www.yellow-bricks.com/2014/05/22/one-versus-multiple-vsan-diskgroups-per- host/ 4 http://www.certmagic.com
2VB-601 QUESTION: 9 Which statement is true about two-node vSAN cluster configuration? A. Two-node configurations do not require a witness host appliance. B. Only the 'Ensure data accessibility' option can be used when entering maintenance mode. C. Two witness host appliances can be simultaneously used for redundancy. D. When a host fails, vSAN rebuilds data on the other host to protect against another failure. Answer: B QUESTION: 10 Which three of the listed categories appear in the vSAN Health user interface? (Choose three.) A. Network B. Physical Disk C. Device Mapping D. Hardware Compatibility Answer: A, B, D QUESTION: 11 Which statement describes vSAN architecture? A. Redundant array of independent disks (RAID) B. Virtual Machine File System (VMFS) on local mirrored storage devices C. Local storage devices aggregated into a single datastore shared by all hosts in the cluster D. Block storage enabled through redundant virtual storage appliances Answer: C References: https://docs.vmware.com/en/VMware- 5 http://www.certmagic.com
2VB-601 vSphere/5.5/com.vmware.vsphere.storage.doc/GUID-ACC10393- 47F6-4 QUESTION: 12 An administrator is designing a vSAN cluster for a number of new workloads. The design calls for the use of erasure coding with RAID 5. Which statement is true about what is needed to meet the needs of this scenario? A. vSAN Standard licensing is sufficient B. vSAN Enterprise licensing is required C. An all-flash configuration is required. D. Six nodes are required at a minimum. Answer: C Explanation RAID 5 or RAID 6 erasure coding is available only on all-flash disk groups. References: https://docs.vmware.com/en/VMware- vSphere/6.5/com.vmware.vsphere.virtualsan.doc/GUID-6D818555-8DE8 QUESTION: 13 What is the procedure for presenting an iSCSI LUN as a target for a VMFS datastore? A. Ensure that the ANY_INITIATOR is listed in the Allowed Initiators tab in vSAN iSCSI Target configuration. B. Add as a traditional VMFS datastore and connect using the vSAN iSCSI Target IQN. C. The use of the vSAN iSCSI Target for providing storage directly to vSphere is not currently supported. D. Use iSCSI vCenter Server Plugin on the target ESXi host. Answer: C Explanation Virutal SAN iSCSI Target for providing storage directly to vSphere is not currently supported. 6 http://www.certmagic.com
2VB-601 QUESTION: 14 Which three statements are true regarding vSAN networking requirements? (Choose three.) A. Each host must have minimum bandwidth dedicated to vSAN:Dedicated 1 Gbps for hybrid configurations.Dedicated or shared 10 Gbps for all-flash configurations. B. vSAN supports both IPv4 and IPv6. C. Each host on the vSAN cluster must have a VMkernel network adapter with vSAN traffic enabled. D. Each host in a vSAN cluster must use NIC teaming with NetFlow enabled. E. The vSAN port group must have Promiscuous Mode enabled. Answer: A B C References: https://docs.vmware.com/en/VMware- vSphere/6.5/com.vmware.vsphere.virtualsan.doc/GUID-AFF133BC- F4B QUESTION: 15 Exhibit: View the exhibit. The following are configuration details for a three-node all-flash vSAN cluster What is the raw capacity of this cluster as configured? A. 6.6 TB 7 http://www.certmagic.com
2VB-601 B. 3 TB C. 6 TB D. 4 TB Answer: C Explanation To determine the raw capacity of a Virtual SAN datastore, multiply the total number of disk groups in the cluster by the size of the capacity devices in those disk groups, and subtract the overhead required by the Virtual SAN on-disk format. References: QUESTION: 16 Which VMware-recommended tool provides specific information on the best strategy for a vSAN deployment? A. vSAN VIP Assessment Tool B. vSAN TCO and Sizing Calculator C. vSAN Health Check UI D. vSAN ReadyNode Configurator Answer: D Explanation vSAN ReadyNode Configurator Selecting a vSAN ReadyNode is simple. Choose the vSAN version you want to deploy, pick a ReadyNode profile based on your specific needs, select your preferred server vendor, and then pick one of the available models. Note: vSAN ReadyNode are x86 servers, available from all the leading server vendors, that have been pre-configured, tested and certified for VMware Hyper-Converged Infrastructure Software. Each ReadyNode is optimally configured for vSAN with the required amount of CPU, memory, network, I/O controllers and storage (SSDs, HDDs or flash devices). Some ReadyNode are available with additional options aimed at simplifying purchasing, deployment, and support. These options are only available for select server vendors and ReadyNode models: QUESTION: 17 Which two vSAN configurations require the use of a witness appliance? (Choose two.) 8 http://www.certmagic.com
2VB-601 A. two-node configuration B. all-flash configuration C. stretched cluster configuration D. hybrid configuration Answer: A, C QUESTION: 18 Which vSAN health check category displays information about vSAN object health? A. Online Health B. Data C. Limits D. Performance Service Answer: B QUESTION: 19 Which three objects that belong to virtual machines are contained in a vSAN datastore? (Choose three.) A. VM Health Status B. VMDK C. VM Home Namespace D. Performance Statistics E. VM Swap Answer: B, C, E QUESTION: 20 A 16-node vSAN cluster has been deployed in a primary data center. All virtual machines are assigned a storage policy containing the rule Primary level of failures to tolerate = 1. A storage controller in one of the nodes produces several errors and eventually suffers a permanent failure. How does vSAN handle this issue? 9 http://www.certmagic.com
2VB-601 A. All components on the drives attached to the failed storage controller are marked "Stale". An administrator must log into the vSphere Web Client and click the Repair Objects Immediately button to restore redundancy. B. All components on the drives attached to the failed storage controller are marked "Stale". vSAN starts rebuilding the affected components on other healthy drives in the vSAN cluster after 60 minutes have elapsed. C. All components on the drives attached to the failed storage controller are marked "Absent". vSAN starts rebuilding the affected components on other healthy drives in the vSAN cluster after the affected host is put into maintenance node. D. All components on the drives attached to the failed storage controller are marked "Degraded". vSAN immediately starts rebuilding the affected components on other healthy drives in the vSAN cluster. Answer: D 10 http://www.certmagic.com