1 / 21

S5 Rotary System for Efficient Root Canal Treatment

Introducing the new S5 Rotary File System by Sendoline for fast, safe, and efficient root canal treatment. Complete with 5 files with unique S-profile, shorter shanks for accessibility, and progressive flutes to prevent screw-in-effect. Designed for use with S5 Endo Motor. Achieve cordless freedom and versatility with only 5 settings across all files. Perfectly matched for precise localization and preparation. Enhance apical depth and width with a reverse sequence technique.

Olivia
Download Presentation

S5 Rotary System for Efficient Root Canal Treatment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Sendoline introduces a new rotary file system Fast, Safe and Efficient

  2. 23 mm 18 mm 8/30 6/30 4/30 4/25 4/20 • S5 Rotary Files • Only 5 files and all with the unique S-profile • Shorter shanks (13 mm) for better accessibility • Long progressive flutes to prevent the “screw-in-effect”, and • Enhanced debris transportation • Developed and intended to be used with the S5 Endo Motor • S5 Endo Motor • Perfect match:S5 Endo Motor + S5 Rotary files = S5 Rotary System • Uses only 5 settings with 5 files (S5 Rotary Files) • Complete versatility, works with most rotary file systems • Cordless freedom: no cables

  3. Localize all the root canals with a manual K or S-file no. 15.

  4. Localization • S-file shown

  5. Prepare the coronal and middle sections of the canal • with S5 file no. 1, motor setting 1.

  6. 8/30 8/30 • File 1 1 2 3 4 5 Motor Setting 1

  7. Continue with file no. 2, motor setting 2, • for as long as the instrument moves toward the apical section. • You often reach a depth of at least 2/3 of the root canal.

  8. 6/30 6/30 • File 2 8/30 1 2 3 4 5 Motor Setting 2

  9. Continue with file no. 3, motor setting 3 • working toward the apical section of the canal.

  10. 8/30 6/30 4/30 4/30 • File 3 1 2 3 4 5 Motor Setting 3

  11. Using file no. 4, motor setting 4, • the working length is normally reached.

  12. 8/30 4/25 4/25 • File 4 1 2 3 4 5 6/30 4/30 Motor Setting 4

  13. If needed, continue with file no. 5, • using motor setting 5.

  14. 4/20 4/20 • File 5 8/30 1 2 3 4 5 6/30 4/30 4/25 Motor Setting 5

  15. Pending on the desired apical width, • follow a reverse sequence using files no. 5-4-3-2, • to enlarge the apical depth. Use corresponding motor settings.

  16. 4/20 Apical Preparation File 5 1 2 3 4 5 Motor Setting 5

  17. Apical Preparation 4/25 File 4 1 2 3 4 5 Motor Setting 4

  18. Apical Preparation 4/30 File 3 1 2 3 4 5 Motor Setting 3

  19. Apical Preparation 6/30 File 2 1 2 3 4 5 Motor Setting 2

  20. 8/30 6/30 4/30 4/25 4/20 S5 Rotary Files S5 Endo Motor PERFECT MATCH!

More Related