1 / 29

The EDELWEISS-II experiment

The EDELWEISS-II experiment. Silvia SCORZA Université Claude Bernard- Institut de Physique nucléaire de Lyon CEA-Saclay DAPNIA/DRECAM (FRANCE), CNRS/CRTBT Grenoble (FRANCE), CNRS/IN2P3/CSNSM Orsay (FRANCE), CNRS/IN2P3/IPN Lyon (FRANCE),

aaron
Download Presentation

The EDELWEISS-II experiment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The EDELWEISS-II experiment Silvia SCORZA Université Claude Bernard- Institut de Physique nucléaire de Lyon CEA-Saclay DAPNIA/DRECAM (FRANCE), CNRS/CRTBT Grenoble (FRANCE), CNRS/IN2P3/CSNSM Orsay (FRANCE), CNRS/IN2P3/IPN Lyon (FRANCE), CNRS/INSU/IAP Paris (FRANCE), CNRS-CEA/Laboratoire Souterrain de Modane (FRANCE), JINR Dubna (RUSSIA), FZK/Universtat Karlsruhe (GERMANY)

  2. Direct Search Principle Detection of the energy deposited due to elastic scattering off target nuclei • Low energy threshold • Large detector mass • Low background • Radio – purity • Active/passive shielding • Deep underground sites • Event Rate : < 1 ev /kg/week • Recoil Energy : 1 – 100 keV

  3. EDELWEISS @ LSM

  4. EDW–II set-up • Radiopurity • dedicated HPGe detectors for systematic checks of all materials • Strict control of bkg: material selection/cleaning procedure/Environment  Shielding • 20 cm Pb shielding • 50 cm PE and better coverage • active μ veto (> 98% coverage) • Up to 110 detectors -> 40kg Ge detector • Ge/NTD • Develop new ID detectors  Goal: EDW-I × 100 σW-n≤ 10-8 pb <0.003 evts/kg/day (Er>10keV)

  5. <300GeV> Veto Polyethylene n Cu(Cryostat) rock  Ge ´ Veto n Pb Gd-loaded scintillator p,π,α Pb µ-veto Candidates for coincident veto-bolometer events Accidental coincidences Expected from Geant4 simulation: ~0.03 events/kg.d Measured: 0.04 events/kg.d

  6. Ge Heat-Ionization Detectors • Simultaneous measurements: • Ionization @ few V/cm with Al electrodes • Heat@ 20 mK with Ge/NTD sensor • Different Ionization/Heat energy ratio for nuclear and electronic recoils (dominate bkg)

  7. Event by event background rejection

  8. Edw-I limiting background PRD71, 122002 (2005) Problem: Surface electron recoils Interpretation: • Bad charge collection (trapping and recombination) • Indications of 210Pb contamination (exposition to Radon): • α rate ~ e rate ~ 4 /kg.day

  9. 210Pb a 210Po 206Pb β 210Pb source 210Pb 210Po

  10. 5 kgd EDW-I ~4 /kgd 95 kgd EDW-II ~2 /kgd preliminary GeNTD data: improved bkg • 210Pb-chain background: reduction of x2 relative to EDELWEISS-I • Gamma background: reduction of x3 relative to EDELWEISS-I Full volume Conclusion: Reduction of background from EDW-I to EDW-II Further bkg reductions after fiducial + coincidence cuts

  11. Physics run: GeNTD Question: How to reach < 10-8 pb ? • 11 detectors with <30 keV threshold • Threshold chosen before start of run (EDW-I results  expected  bkg) • 93.5 kg.day • 3 events observed in nuclear recoil band • 31, 31 and 42 keV • Evidence for events with deficient charge collection from 210Pb NEED • >1000 kgd at 15 keV threshold • >105 rejection for gammas • to reject expected >4000  from 210Pb Preliminary EDELWEISS 93.5 kgd IDea: Develop detectors with surface event rejection using interleaved electrode design (ID)

  12. G B A B A B A A A B → → → → E E E E Fiducial volume Guard Electron trajectories hole trajectories C D C D C D C C D H ID detector • NTD heat sensor • E-field modified near surface with interleaved electrodes • B+D signals -> vetos % surface • 1x200g + 3x400g tested in2008 • 10x400g running ‘A’ electrodes: +2V ‘B’ electrodes: +1V Z (cm) guard ‘G’: + 1V ‘A&B’ near- surface event ‘A&C’ bulk event ‘A,B&C’ event in low-field area guard ‘H’: - 1V ‘C’ electrodes:-2V ‘D’ electrodes: -1V Radius (cm)

  13. ID detector rejection • Beta rejection of 200g • Gamma rejection of 400g • ~1 month calibrations 6x104 210Po 6x104 210Bi 6x104 -equivalent to ~103 kgd -equivalent to 3x104 kgd 0 events

  14. Physics run: ID detectors Conclusion: This is the good technology for 10-8 pb and beyond • 1 x 400g + 1 x 350g detectors, 86 live days • <15 keV threshold achieved for exposure of 18.6 kg.days • 50% efficiency at 10 keV • No events in (or around) nuclear recoil band

  15. Limits • 93.5 kgd GeNTD • 11 detectors x 4 months • 30 keV threshold • 3 events observed in nuclear recoil band • 18.3 kgd ID • 2 detectors x 4 months • 15 keV threshold • No nuclear recoils • No evts outside  band • 2009: 10 ID detectors • improvement in sensitivity: 4x10-8 pb • More detectors build in 2009 Preliminary

  16. Conclusions/Outlook • Significant reduction in , β and γ backgrounds relative to EDELWEISS-I • Improved understanding of backgrounds and of response of detectors to backgrounds • Improved limit relative to EDELWEISS-I • Passive background reduction alone not sufficient to reach < 10-8 pb • ID detectors have the surface rejection needed to reach this goal • Running in 2009 with 10 x 400g detectors • Prototype of ID detectors with larger fiducial volumes currently in test • EURECA = 1 ton scale experiment (CRESST, EDELWEISS, CERN, …) @ LSM extension

  17. This is the end…

  18. g46.5 keV (4%) 210Pb Cu few mm e-61 keV max 206Pb e-10keV - 100keV - 1MeV 22 yr 210Bi g 46 keV a 5 mm e-1.16MeV max Al 70nm ~50 nm 210Po NO ionisation amGe 70nm 206Pb a 350 nm 20 mm 100 keV 5.3 MeV Ge 2cm 700 mm 3 mm Decay Chain

  19. 210Pb β 210Po a E=5.3 MeV Q~0.3 206Pb EDELWEISS-II 210Pb source calibration • Confirms interpretation of EDW-I bkg as 210Pb surface . • Response of detectors to this important background Edw-II 210Pb EDELWEISS-II 210Pb source 210Bi Edw-II 210Bi 210Po Edw-II Edw-I data 206Pb recoils coincident with 210Po  Implantation depth of 210Pb

  20. EURECA - II

  21. EURECA-I

  22. France-Italy Fréjus tunnel :new safety gallery planned Existing lab s ? Existing road tunnel • 2 projects • Limited extension • Very large cavity

  23. Implantation of new lab First drawings nov 2006 (Lombardi eng company) G Gerbier EURECA ULISSE meeting- Lyon july 2008 24

  24. Compatibility DAMA other experiments SI

  25. Compatibility DAMA other experiments SD

  26. Present limits

  27. Experimental data Number of events in WIMP region: q< 0.5, 25 < E < 60 кэВ registered 23 events Alpha rate 2.5 events

  28. Estimation of background from 210Pb 460 events N alphas in calibration spectrum = 3040 events Number of events in WIMP region: q< 0.5, 25 < E < 60 кэВ registered = 460 events Expected number events from calibration with 210Pb = 37 events

More Related