1 / 15

An Introduction to the R3 19 inch Rack

An Introduction to the R3 19 inch Rack. The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular function within the complete control panel. Modules cover all requirements - Fire detection Alarm signalling Gas detection Extinguishing

abdul-haney
Download Presentation

An Introduction to the R3 19 inch Rack

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. An Introduction to the R3 19 inch Rack • The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular function within the complete control panel. • Modules cover all requirements - • Fire detection • Alarm signalling • Gas detection • Extinguishing • Data transmission • Plant control • The modular approach means that the system is inherently reliable, easy to install and commission and easy to maintain, repair and fault find.

  2. Common Control Module • Every R3 system must contain a Common Control Module. • This module incorporates all executive action user controls. • There are two types - • K1321 - Conventional systems only • K1339 - Both analogue addressable and conventional systems • The Common Control Module is always fitted in the right hand module position of its designated rack.

  3. K1339 Common Control Module • User Controls • System Messages • User Indications • Engineer Functions • Printer Output • Event Memory • Network Data Output

  4. K1339 Common Control Module • User Controls • Silence Alarms • Reset System • Test Alarms • Silence Buzzer • Test Lamps

  5. K1339 - Silence Alarms Press Key 1 Alarms silence “Alarms Silenced” indicator lights Panel buzzer sounds

  6. K1339 - System Reset Press Key 2 Message display clears “Alarms Silenced” indicator goes out Buzzer stops System is reset

  7. K1339 - 1 Fire Message Event message shows loop number and device address with device type and status in line 1. Second line is a user defined description of the area where the device is located.

  8. K1339 - 2 Fire Messages First event remains in lines 1 and 2. Second event is shown in lines 3 and 4. (Example shown where smoke is detected on stairs and a break glass is operated later.).

  9. K1339 - Further Events First event remains in lines 1 and 2. Second event is shown in lines 3 and 4. “More Data” LED is lit. Pressing key 6 scrolls next event into lines 3 and 4.

  10. K1339 - More Data Display First event remains in rows 1 and 2 of display. Pressing key 6 scrolls later events into the bottom 2 lines until all events have been viewed.

  11. K1339 Common Control Module • Engineer Controls • (via Access Code) • Time and Date • Text Messages • Device Isolate • Printer Dump • Memory

  12. K1339 Common Control Module -Engineer Controls • Text Messages • Sensors • Zones • Indication Zones • Inputs

  13. K1339 Common Control Module -Engineer Controls • Device Isolate • Single / Range Isolate • Single / Range De-isolate • De-isolate All • List Isolations • Print Isolations

  14. K1339 Common Control Module -Engineer Controls • Printer • Printer Dump • Clear Print Queue • Normal Print • Reverse Print

  15. K1339 Common Control Module • Event Memory • View All Events in Reverse Order