90 likes | 242 Views
Report: Radiation Levels in LHC Points 2 and 8 due to beam dumping on the TEDs at the bottom of TI2 and TI8 Helmut Vincke and Graham R. Stevenson CERN–TIS–2003–013–RP–TN. TED used for TI test. High E muon radiation. Low muon and hadronic radiation. Total dose rate seen at Alice.
E N D
Report: Radiation Levels in LHC Points 2 and 8 due to beam dumping on the TEDs at the bottom of TI2 and TI8 Helmut Vincke and Graham R. Stevenson CERN–TIS–2003–013–RP–TN
During the highest beam intensities (3.2E11 protons on TED) we measured about 50 uSv/h along the beam axis. The correlation factor between dose (H*10) and muonfluence is: 40 fSv.m2 Major part of detector signal is caused by muons. At PMI position we saw about 400 muons/cm2 per 3.2E11 protons
Dose rate in the Alice counting rooms (non designated area during test)