1 / 16

Limit state design (LSD) refers to a design method for RCC Structures

Limit state design (LSD) refers to a design method for RCC Structures. UNIT-II. Topics Covered in this unit are. LEARNING OBJECTIVES After completion of this unit, student will be able to Understand the design philosophies Understand the concepts of limit state design

achristine
Download Presentation

Limit state design (LSD) refers to a design method for RCC Structures

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Limit state design (LSD) refers to a design method for RCC Structures

  2. UNIT-II Topics Covered in this unit are

  3. LEARNING OBJECTIVES After completion of this unit, student will be able to Understand the design philosophies Understand the concepts of limit state design List the assumptions in limit state design Derive the stress block parameters UNIT-II

  4. In the working stress or allowable stress method of design, the emphasis is on limiting a particular stress in a component to a fraction of the specified strength of the material of the component. • The magnitude of the factor for a structural action depends upon the degree of safety required. Further, elastic behaviour of the material is assumed. • The main objection to the permissible stress method is that the stress safety factor relating the permissible stress to the strength of the material is not usually the same as the ratio of the strength to the design load. • Thus it does not give the degree of safety based on collapse load.

  5. In the limit state method, both collapse condition and serviceability condition are considered. In this method, the structure has to be designed to withstand safely all loads and deformations likely to occur on it throughout its life. Designs should ensure that the structure does not become unfit for the use for which it is required. The state at which the unfitness occurs is called a limit state

  6. Limit State: • Condition in which a structure or structural element is no longer acceptable for its intended use. • Major groups for RC structural limit states • Ultimate • Serviceability • Special

  7. Ultimate limit state • structural collapse of all or part of the structure ( very low probability of occurrence) and loss of life can occur. • Loss of equilibrium of a part or all of a structure as a rigid body (tipping, sliding of structure).

  8. Limit state design requires the structure to satisfy two principal criteria: • the ultimate state (ULS) and • the serviceability limit state (SLS) • A limit state is a set of performance criteria (e.g. vibration levels, deflection, strength, stability, buckling, twisting, collapse) that must be met when the structure is subject to loads.

  9. Limit state of collapse • Flexure • Shear • Compression • Torsion

  10. Limit state of serviceability • Deflection • vibration

  11. Serviceability Limit State • To satisfy the serviceability limit state criteria, a structure must remain functional for its intended use subject to routine (read: everyday) loading, and as such the structure must not cause under routine conditions

  12. Special features of limit state design method are: • It is possible to take into account a number of limit states depending upon the particular instance • This method is more general in comparison to the working stress method. In this method, different safety factors can be applied to different limit states, which is more rational than applying one common factor (load factor) as in the plastic design method. • This concept of design is appropriate for the design of structures since any new knowledge of the structural behaviour, loading and materials can be readily incorporated.

More Related