1.01k likes | 1.33k Views
Contents. Chapter 1 SAFETY STANDARDS 1.1 Risk Assessment for machine builders 1.2 Risk Reduction 1.3 Safety Category 1.4 Safety Integrity Level (SIL) Chapter 2 SAFETY PLC SYSTEM 2.1 Hardware 2.2 Specifications 2.3 Functions 2.4 Melsecnet/H Chapter 3 CC-LINK SAFETY SYSTEM
E N D
Contents Chapter 1 SAFETY STANDARDS 1.1 Risk Assessment for machine builders 1.2 Risk Reduction 1.3 Safety Category 1.4 Safety Integrity Level (SIL) Chapter 2 SAFETY PLC SYSTEM 2.1 Hardware 2.2 Specifications 2.3 Functions 2.4 Melsecnet/H Chapter 3 CC-LINK SAFETY SYSTEM 3.1 Hardware 3.2 Specifications 3.3 Functions Chapter 4 GX DEVELOPER 4.1 Registering user when creating new project 4.2 Registering / Deleting / Changing Login User 4.3 Access level 4.4 CPU access password 4.5 Safety CPU operation mode (Safety mode and test mode) 4.6 Operation lock 4.7 Safety PLC Diagnostics Chapter 5 APPLICATION EXAMPLE 5.1 Emergency Stop Circuit
Chapter 1 Safety Standards 1.1 Risk Assessment for machine builders Customer requires “Risk Assessment” of system, as to conform to IEC61508 SIL 1..4, or ISO13849-1 Category 1..4
Chapter 1 Safety Standards 1.1 Risk Assessment for machine builders Implementation of risk reduction measures to bring the risk factors to a permissible level
Chapter 1 Safety Standards 1.2 Risk Reduction
Chapter 1 Safety Standards 1.3 Safety Category
Chapter 1 Safety Standards 1.3 Safety Category
Chapter 1 Safety Standards 1.3 Safety Category
Chapter 1 Safety Standards 1.4 Safety Integrity Level (SIL)
Chapter 2 Safety PLC System 2.1 Hardware 4 Slots CC-Link Safety Melsecnet/H
Chapter 2 Safety PLC System 2.1 Hardware
Chapter 2 Safety PLC System 2.1 Hardware
Chapter 2 Safety PLC System 2.1 Hardware
Chapter 2 Safety PLC System 2.1 Hardware Precautions • The extension base units cannot be connected • The multiple CPU system cannot be configured • The only modules which can be mounted on the I/O slots are : 1. CC-Link Safety Master module 2. Melsecnet/H modules 3. Blank modules If a module other than the ones mentioned above is mounted, “Module Layout Error“ (Error Code : 2125) is detected. • GOT´s cannot be connected
Chapter 2 Safety PLC System 2.2 Specifications CPU Module
Chapter 2 Safety PLC System 2.2 Specifications CPU Module
Chapter 2 Safety PLC System 2.2 Specifications CPU Module
Chapter 2 Safety PLC System 2.2 Specifications CPU Module
Chapter 2 Safety PLC System 2.2 Specifications Power Supply Module
Chapter 2 Safety PLC System 2.2 Specifications Power Supply Module
Chapter 2 Safety PLC System 2.2 Specifications Power Supply Module When a momentary power failure less than 20ms ends, the operation processing is resumed.
Chapter 2 Safety PLC System 2.3 Functions • Two safety CPU operation modes • SAFETY MODE is a mode for safe system operation. No program download and no device forcing available • TEST MODE is a mode for maintenance and programming
Chapter 2 Safety PLC System 2.3 Functions • 3000 entries for operation history and error history
Chapter 2 Safety PLC System 2.3 Functions • Redundant CPU • The operation results of CPU A/CPU B are compared, • and output only when the results are matched so that • incorrect outputs can be prevented.
Chapter 2 Safety PLC System 2.3 Melsecnet/H • 1 MELSECNET/H module applicable • Normal Station available (only) • No transient communication available • The Safety CPU can not be programmed via MELSECNET/H
Chapter 2 Safety PLC System 2.3 Melsecnet/H
Chapter 2 Safety PLC System 2.3 Melsecnet/H
Chapter 2 Safety PLC System 2.3 Melsecnet/H
Chapter 2 Safety PLC System 2.3 Melsecnet/H
Chapter 3 CC-Link Safety System 3.1 Hardware 2 applicable master modules to one safety PLC system Up to 64 stations of safety remote I/O stations, standard remote I/O stations and remote device stations can be connected to a single safety master station.
Chapter 3 CC-Link Safety System 3.1 Hardware 42 Safety slaves are connectable to one safety master module
Chapter 3 CC-Link Safety System 3.1 Hardware Usable CC-Link Slave stations
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Master Safety CC-Link Master QS0J61BT12
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Master
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Master
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety System
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety System
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety System Maximum overall cable distance (V1.10)
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave Safety CC-Link Slave QS0J65BTB2-12DT
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave
Chapter 3 CC-Link Safety System 3.2 Specifications CC-Link Safety Slave
Chapter 3 CC-Link Safety System 3.3 Functions