1 / 6

Base Point Deviation – NPRR377 GREDP Inputs

Settlement and Extracts Group June 20, 2011 Base Point Deviation – NPRR377 ERCOT Settlement & Billing Group. Base Point Deviation – NPRR377 GREDP Inputs. Base Point Deviation – NPRR377 GREDP Inputs. Calculate an over generation and under generation for each 5 minute clock interval

adlai
Download Presentation

Base Point Deviation – NPRR377 GREDP Inputs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Settlement and Extracts GroupJune 20, 2011Base Point Deviation – NPRR377ERCOT Settlement & Billing Group

  2. Base Point Deviation – NPRR377 GREDP Inputs

  3. Base Point Deviation – NPRR377 GREDP Inputs

  4. Calculateanovergeneration and undergenerationforeach 5 minute clockinterval OGEN5M q, r, p, i, y = Max[0, (AVGTG5M q, r, p, i, y – Max[(1 + K1) * AABP5M q, r, p, i, y, AABP5M q, r, p, i, y + Q1])] K1 = 5 % Q1 = 5 MW UGEN5Mq, r, p, i ,y= Max [0, [Min ((1 - K2) * AABP5Mq, r, p, i, y, AABP5Mq, r, p, i, y - Q2) - AVGTG5M q, r, p, i, y]] K2 = 5 % Q2 = 5 MW Where: AABP5Mq, r, p, i, y = AVGBP5M q, r, p, i, y + AVGREG5M q, r, p, i, y AVGREG5M q, r, p, i, y = (AVGREGUP5Mq, r, p, i, y - AVGREGDN5Mq, r, p, i, y) y = 5-minute clock interval Base Point Deviation – NPRR377 GREDP Inputs

  5. Once the over and under volume for each 5 minutes is calculated, then apply the price for the 15 minute settlement interval. Over Generation: BPDAMT q, r, p, i = Max (PR1, RTSPP p, i) * (OGEN q, r, p, i *1/12) OGEN q, r, p, i = (OGEN5M q, r, p, i, y) Under Generation: BPDAMT q, r, p, i= -1 * Min (PR2, RTSPPp,i) * Min (1, KP) * (UGENq, r, p, i * 1/12) UGENq, r, p ,i = (UGEN5Mq, r, p, i, y) Base Point Deviation – NPRR377 GREDP Inputs

  6. [ab1]Some of the cons seemed the same, maybe my notes weren’t good • Base Point Charges for IRR are upgraded to calculate on a 5 minute clock interval basis • Please note: • Charges will be assessed for each 5 minute clock interval where the resource received a flag signifying a Base Point below HDL for all SCED intervals within the five-minute clock interval • KIRR is changed to 5% Base Point Deviation – NPRR377 changes for IRR

More Related